6.
Fit the low-profile bracket onto the NI PCI-8366 by aligning the square cutout on the
bracket with the SFP receptacle on the card. Ensure the two mounting tabs on the
low-profile bracket rest against the back side of the card. The mounting holes are aligned
with the threaded holes on the mounting tabs of the bracket, and the LED bulb is situated
in the bracket display hole correctly.
7.
Install the two Phillips screws from the front side of the card. Tighten each screw to a
maximum torque of 3.6 lb · in. (0.407 N · m).
8.
Hold the SFP module in the orientation shown in Figure 3-3. Ensure the release lever is
closed in its upright position and gently slide the SFP module into the SFP receptacle. The
SFP module will click into place when fully engaged, as shown in Figure 3-5.
Figure 3-5.
Completed Low-Profile Bracket Installation on the NI PCI-8366
Installing an NI ExpressCard-8360 Host Card
Because a laptop is not grounded, follow this procedure to safely connect it to your PXI system:
1.
Install the NI PXI-8360, NI PXI-8361, or NI PXIe-8360 as directed in the
NI PXI-8360/8364/8367/8368 or NI PXIe-8360/8364 Board
section where applicable.
2.
Touch the NI ExpressCard-8360 and a metal part of the PXI chassis simultaneously. Do not
install it into the laptop or embedded controller yet.
3.
Connect the cable to the NI ExpressCard-8360 and target chassis.
4.
Plug the NI ExpressCard-8360 into an available ExpressCard slot.
If your computer is already running (or hibernating, etc.) when you install an NI ExpressCard-8360,
you must reboot to detect the PXI system. Otherwise, the PXI system is detected when you start your
computer.
Figure 3-6 shows how to insert the NI ExpressCard-8360 into a laptop and connect the cable.