background image

Connecting to the Development Computer Over a Network

To connect over a network, the device must be on the same subnet as the development
computer. Complete the following steps to connect the device to the development computer
over a network.
1.

Verify the development computer is powered on and connected to the network.

2.

Connect one end of an Ethernet cable to the network port on the device.

3.

Connect the free end of the cable to an Ethernet switch or other network device on the
same network as the development computer.

4.

Verify the ACTIVITY/LINK LED on the port is on or blinking.

The device negotiates an IP address when connected to a network with a DHCP server or
comparable network device.

Using Vision Builder AI with the IC-3121

Complete the following steps to use Vision Builder AI with the IC-3121:
1.

Install Vision Builder AI on the development computer.

2.

Refer to the 

How to Configure NI Vision Builder AI Remote Targets

 section in the 

Vision

Builder for Automated Inspection: Configuration Help

.

When using Vision Builder AI, it is not necessary to install the NI Industrial Controller Device
Drivers or use NI MAX to set a system password on the target.

Installing the NI Industrial Controller Device Drivers

Before using the IC-3121, install the drivers onto the device. Complete the following steps to
install and configure NI Industrial Controller Device Drivers:
1.

Install NI Industrial Controller Device Drivers onto the Windows development machine
connected to the IC-3121.

2.

Run NI MAX.

3.

Expand the 

Remote Systems

 list in the configuration tree.

4.

Select the IC-3121 in the list. By default, MAX lists devices by the model number
followed by the serial number, such as IC-3121-XXXXXXXX.

5.

Configure the network settings for the IC-3121. Refer to the 

Remote Systems Help

 in

MAX. Select 

Help

»

Help Topics

»

Remote Systems

 for instructions about configuring

network settings.

6.

Install a recommended software set. If you would like to install custom software instead
of a recommended software set, proceed to the next step.
a)

Expand the IC-3121 under 

Remote Systems

.

b)

Click the 

Software

 item below the IC-3121 in the configuration tree.

c)

Click 

Add/Remove Software

 on the MAX toolbar to launch the LabVIEW Real-

Time Software Wizard.

d)

Enter 

admin

 as the username and leave the password field blank.

e)

Select 

NI Industrial Controller

 under the version of LabVIEW Real-Time you are

using.

IC-3121 Getting Started Guide

  | 

© National Instruments

  | 

7

Содержание IC-3121

Страница 1: ...shooting 9 Where to Go Next 13 Worldwide Support and Services 13 Safety Information Caution The following paragraphs contain important safety information you must follow when installing and operating...

Страница 2: ...efore returning it to service You must insulate signal connections for the maximum voltage for which the device is rated Do not exceed the maximum ratings for the device Remove power from signal lines...

Страница 3: ...ibility of static electricity damage Refer to the following figures while configuring the hardware Figure 1 IC 3121 Power Connectors and Reset Button SYSTEM 12 24 V C V ISO 5 24 V 2 3 1 4 C ISO V ISO...

Страница 4: ...3 0 Ports 6 44 pin Digital I O Connector Connecting the System Power Supply NI recommends the following power supply for the IC 3121 Power Supply Part Number NI PS 15 Industrial Power Supply 781093 01...

Страница 5: ...lug and tighten the terminal screw to 0 2 to 0 25 N m 1 8 to 2 2 lb in of torque 5 Install the power connector plug into the SYSTEM power receptacle on the IC 3121 chassis and tighten the connector sc...

Страница 6: ...ws to 0 4 N m 3 5 lb in of torque 6 Turn on the external power source Configuring the IC 3121 for NI Linux Real Time The real time version of the IC 3121 ships preloaded with NI Linux Real Time Comple...

Страница 7: ...NI MAX to set a system password on the target Installing the NI Industrial Controller Device Drivers Before using the IC 3121 install the drivers onto the device Complete the following steps to instal...

Страница 8: ...the IC 3121 restarts i Click Finish 8 Connect hardware to the IC 3121 The NI Industrial Controller Device Drivers enable the IC 3121 to detect any hardware connected 9 Select the target in the configu...

Страница 9: ...P connection it connects to the network with a link local IP address 169 254 x x Installing the NI Industrial Controller Device Drivers Before using the IC 3121 install other National Instruments soft...

Страница 10: ...rform an IP RESET The cable you are using may be inappropriate for the speed of your network causing network communication dropout While 1 000 Mbps communication over short cable lengths can be achiev...

Страница 11: ...ivers on page 7 Cannot Drive Isolated Outputs Verify that you have power connected to the VISO and CISO inputs on the IC 3121 isolated power connector and that the contact at the screw terminals is so...

Страница 12: ...the exception state alerting you to resolve the problem Reinstall software on the IC 3121 or contact NI for assistance Refer to the IC 3121 Getting Started Guide for information about installing soft...

Страница 13: ...Factory Installation Services repairs extended warranty and other services Visit ni com register to register your NI product Product registration facilitates technical support and ensures that you rec...

Страница 14: ...party legal notices in the readme file for your NI product Refer to the Export Compliance Information at ni com legal export compliance for the NI global trade compliance policy and how to obtain rel...

Отзывы: