background image

Figure 4. 2-Position Power Screw Terminal Connector

1

2

3

1. V (Positive) Terminal Screw
2. C (Negative) Terminal Screw
3. Connector Screws

Caution

 

Do not tighten or loosen the terminal screws on the power connector

while the power is on.

4.

Connect the positive lead of the power source to the V terminal of the power connector
plug and tighten the terminal screw to 0.2 to 0.25 N · m (1.8 to 2.2 lb · in.) of torque.

5.

Connect the negative lead of the power source to the C terminal of the power connector
plug and tighten the terminal screw to 0.2 to 0.25 N · m (1.8 to 2.2 lb · in.) of torque.

6.

Install the power connector plug into the SYSTEM power receptacle on the IC-3120
chassis and tighten the connector screws to 0.4 N · m (3.5 lb · in.) of torque.

7.

Turn on the external power source.

Connecting the Isolated Outputs Power Supply and
PoE Power Supply

NI recommends the following power supplies for the IC-3120.

Power Supply

Part Number

 

 

NI PS-15 Industrial Power Supply, to power the isolated outputs

781093-01

48 V, DIN Rail, Industrial Power Supply for Power over Ethernet

783307-01

48 V, Desktop Power Supply for Power over Ethernet

783308-01

Complete the following steps to supply power to the PoE ports and the isolated outputs.
1.

Verify the power source is turned off.

2.

Install one ferrite across the negative and positive leads of the power sources,
approximately 50 to 75 mm (2 to 3 in.) from the end of the power input wires. If you are
using an isolated output power supply and a PoE power supply, wrap the wires for both
power supplies through the same ferrite.

IC-3120 Getting Started Guide

  | 

© National Instruments

  | 

5

Содержание IC-3120

Страница 1: ...9 Troubleshooting 10 Where to Go Next 13 Worldwide Support and Services 13 Safety Information Caution The following paragraphs contain important safety information you must follow when installing and...

Страница 2: ...efore returning it to service You must insulate signal connections for the maximum voltage for which the device is rated Do not exceed the maximum ratings for the device Remove power from signal lines...

Страница 3: ...ic electricity damage Refer to the following figures while configuring the hardware Figure 1 IC 3120 Power Connectors and Reset Button SYSTEM PoE 48 V ISO C ISO C PoE V PoE V ISO 5 24 V 12 24 V C V 2...

Страница 4: ...ecommends the following power supply for the IC 3120 Power Supply Part Number NI PS 15 Industrial Power Supply 781093 01 Complete the following steps to supply power to the IC 3120 1 Verify the power...

Страница 5: ...to 0 4 N m 3 5 lb in of torque 7 Turn on the external power source Connecting the Isolated Outputs Power Supply and PoE Power Supply NI recommends the following power supplies for the IC 3120 Power S...

Страница 6: ...N m 1 8 to 2 2 lb in of torque 5 Connect the negative lead of the isolated outputs power source to the C2 terminal of the power connector plug and tighten the terminal screw to 0 2 to 0 25 N m 1 8 to...

Страница 7: ...ment computer is powered on and connected to the network 2 Connect one end of an Ethernet cable to the network port on the device 3 Connect the free end of the cable to an Ethernet switch or other net...

Страница 8: ...k Finish 7 Install custom software You do not need to install custom software if you installed a recommended software set a Expand the IC 3120 under Remote Systems b Click the Software item below the...

Страница 9: ...ution NI cannot recover lost system passwords If you forget the password you must contact NI and reformat the controller Configuring the IC 3120 for Windows The Windows version of the IC 3120 ships pr...

Страница 10: ...gured on another network and then moved to the current network Reconfigure the IC 3120 for the current network Note Connect a monitor and keyboard to the IC 3120 and press Enter to view the current co...

Страница 11: ...ed as nati vi server NATI VI Server Used by Vision Builder AI to configure a remote target If your firewall is controlled remotely or you are unsure about configuring the firewall contact your network...

Страница 12: ...the exception state alerting you to resolve the problem Reinstall software on the IC 3120 or contact NI for assistance Refer to the IC 3120 Getting Started Guide for information about installing soft...

Страница 13: ...Factory Installation Services repairs extended warranty and other services Visit ni com register to register your NI product Product registration facilitates technical support and ensures that you rec...

Страница 14: ...party legal notices in the readme file for your NI product Refer to the Export Compliance Information at ni com legal export compliance for the NI global trade compliance policy and how to obtain rel...

Отзывы: