Chapter 5
Diagnostic Tests
©
National Instruments Corporation
5-3
488-VXIbus Interface DIAGNOSTICS:
< XXX DRAM Reported >
Default Diags(all
===> d
Tests
===> t
Test Groups
===> g
Over NightLoop
===> o
Quit
===> q
PRINT TOGGLE
===> p
SINGLE STEP TOGGLE
===> s
LOOPING TOGGLE
===> l
ERROR REPORT TOGGLE
===> e
REPORT ERROR LOG
===> r
CLEAR ERROR LOG
===> c
(Current settings: PRINT(OFF), ERROR(ON), SINGLE(OFF), LOOP(OFF))
Enter Selection
:
By default, single-stepping, looping, and test message printing are turned
off while error reporting is turned on. The selected diagnostics run
uninterrupted until they complete or until an error occurs. If an error has
Table 5-2.
Diagnostics Mode Menu Option Descriptions
Selection
Description
Default Diags (all)
Runs all the tests.
Tests
Presents a menu of tests to be selected.
Test Groups
Presents a menu of test groups to be selected.
Over Night Loop
Runs selected tests continuously. Only stops
when an error occurs or when system is reset.
Print Toggle
Turn printing of test groups/tests on or off.
Single Step Toggle
Turns single-stepping of test groups/tests on
or off.
Looping Toggle
Turns looping of selected test groups/tests on
or off.
Error Report Toggle
Turns printing of error statements on or off.
Report Error Log
Prints the first 11 errors that occurred.
Clear Error Log
Erases the buffer of errors.