7-44
|
ni.com
Chapter 7
Counters
You can use these defaults or select other sources and destinations for the counter/timer signals
in NI-DAQmx. Refer to
Connecting Counter Signals
in the
NI-DAQmx Help
or the
LabVIEW Help
for more information about how to connect your signals for common counter
measurements and generations. X Series default PFI lines for counter functions are listed in
X Series Physical Channels
in the
NI-DAQmx Help
or the
LabVIEW Help
.
CTR 1 A
76 (PFI 3)
CTR 1 Z
77 (PFI 4)
CTR 1 B
87 (PFI 11)
CTR 2 SRC
73 (PFI 0)
CTR 2 GATE
74 (PFI 1)
CTR 2 AUX
75 (PFI 2)
CTR 2 OUT
93 (PFI 14)
CTR 2 A
73 (PFI 0)
CTR 2 Z
74 (PFI 1)
CTR 2 B
75 (PFI 2)
CTR 3 SRC
78 (PFI 5)
CTR 3 GATE
79 (PFI 6)
CTR 3 AUX
80 (PFI 7)
CTR 3 OUT
95 (PFI 15)
CTR 3 A
78 (PFI 5)
CTR 3 Z
79 (PFI 6)
CTR 3 B
80 (PFI 7)
FREQ OUT
93 (PFI 14)
Table 7-10.
X Series USB Screw Terminal Device Default
NI-DAQmx Counter/Timer Pins (Continued)
Counter/Timer Signal
Default Pin Number (Name)
Содержание DAQ X NI 634 Series
Страница 1: ...PXIe 6349...