background image

5

1

3

4

2

1.

Ensure that all the C Series modules are installed in the cRIO-9033 and the latches are
locked in place.

2.

Remove the center right panel screw from the top and bottom of the cRIO-9033 using the
Torx T10 driver.

3.

Slide the bracket into place, aligning the three clearance screw holes.

4.

Install the M4 x 0.7 button-head screw in the right end of the cRIO-9033 using the
appropriate Torx T20 driver. Tighten the screw to a maximum torque of 1.3 N · m
(11.5 lb · in.).

5.

Install the two M3 x 0.5 flat-head screws from the accessory kit in the top and bottom of
the cRIO-9033 using the appropriate Torx T10 driver. Tighten the screws to a maximum
torque of 1.3 N · m (11.5 lb · in.).

Tip

 

NI recommends using a liquid thread locker for all fasteners if the system

is expected to experience vibration for an extended amount or time.

Module Immobilization Accessory Dimensions

The following figure shows the Module Immobilization accessory dimensions for the
cRIO-9033.

NI cRIO-9033 User Manual

  | 

© National Instruments

  | 

23

Содержание cRIO-9033

Страница 1: ...unting and operating the device USB 2 0 Host Port USB 2 0 Device Port 2 GB DDR3L RJ 50 RS 232 Serial Port RJ 50 RS 485 422 DTE Serial Port SD Card Slot Intel Atom E3825 1 33 GHz Dual Core System On Ch...

Страница 2: ...30 Mounting the Device on a Rack 32 Mounting the Device on a Desktop 32 BIOS Configuration 33 Resetting the System CMOS and BIOS Settings 33 Power On Self Test Warning Messages 34 BIOS Setup Utility...

Страница 3: ...g steps to find the cRIO 9033 on a network using DHCP 1 Disable secondary network interfaces on the host computer such as a wireless access card on a laptop 2 Ensure that any anti virus and firewall s...

Страница 4: ...bottom of the window d Select Static on the Configure IPv4 Address control e Enter values for IPv4 Address Subnet Mask Gateway and DNS Server based on the information you recorded Be sure to enter a...

Страница 5: ...ing on prevents any LabVIEW startup applications from running Disable FPGA Startup App Rebooting the cRIO 9033 with this setting on prevents autoloading of any FPGA application Enable Secure Shell SSH...

Страница 6: ...Removable Storage 4 RS 232 Serial Port 5 RS 485 422 DTE Serial Port 6 Mini DisplayPort 7 USB Host Ports 8 USB Device Port RJ 45 Gigabit Ethernet Ports The cRIO 9033 has two tri speed RJ 45 Gigabit Eth...

Страница 7: ...ossover cable to connect to a host computer The following NI Ethernet cables are available for the cRIO 9033 Table 3 RJ 45 Gigabit Ethernet Cables Cables Length Part Number CAT 5E Ethernet Cable shiel...

Страница 8: ...nd V2 inputs the cRIO 9033 operates from the V1 input If the input voltage to V1 is insufficient the cRIO 9033 operates from the V2 input The cRIO 9033 has reverse voltage protection The following NI...

Страница 9: ...shing or lit because file corruption may result Note Screw the slot cover closed completely Tighten the captive screws to a maximum torque of 0 75 N m 6 7 lb in using a 1 Phillips screwdriver Do not o...

Страница 10: ...h Part Number RS 232 S8 Serial Cable 10 Position Modular Plug to 9 Pin DSUB 1 m 182845 01 2 m 182845 02 3 m 182845 03 RS 485 422 DTE Serial Port The cRIO 9033 has an RS 485 422 DTE serial port that is...

Страница 11: ...E Serial Port Accessory Accessory Length Part Number RS 485 S8 Serial Cable 10 Position Modular Plug to 9 Pin DSUB Isolated 1 m 184428 01 Mini DisplayPort Use the Mini DisplayPort to connect a monitor...

Страница 12: ...rt Accessories Accessory Length Part Number Mini DisplayPort to Full DisplayPort Native Cable 0 5 m 157232 0R5 1 m 157232 01 2 m 157232 02 Mini DisplayPort to VGA Adapter Cable 0 5 m 157230 0R5 Mini D...

Страница 13: ...152166 02 Related Information File System on page 21 Installing a Ferrite on the USB Cables You must install a ferrite around all USB cables connected to the USB host ports to ensure that the cRIO 903...

Страница 14: ...errupting communication on the RJ 45 Ethernet ports Caution Do not hot swap USB devices while the cRIO 9033 is in a hazardous location or connected to high voltages If the cRIO 9033 is not in a hazard...

Страница 15: ...u on page 36 RESET Button Press the RESET button to reset the processor in the same manner as cycling power Troubleshooting Network Connectivity You can use the RESET button to troubleshoot network co...

Страница 16: ...settings reset RT Startup App disabled FPGA Startup App disabled Console Out enabled RT Startup App disabled FPGA Startup App disabled Safe Mode USER1 Button The cRIO 9033 has a general purpose USER1...

Страница 17: ...lists the POWER LED indicators Table 16 POWER LED Indicators LED Color LED Pattern Indication Green Solid The cRIO 9033 is powered from the V1 input Yellow Solid The cRIO 9033 is powered from the V2 i...

Страница 18: ...the Measurement Automation Explorer MAX Help for information about safe mode Blinks four times and pauses The cRIO 9033 is in safe mode The software has crashed twice without rebooting or cycling pow...

Страница 19: ...able 19 Ethernet LED Indicators LED LED Color LED Pattern Indication ACT LINK Off LAN link not established Green Solid LAN link established Flashing Activity on LAN 10 100 1000 Yellow Solid 1 000 Mbit...

Страница 20: ...solid copper wire with a maximum length of 1 5 m 5 ft Attach the wire to the earth ground of the electrode system of the facility Caution If you use shielded cabling to connect to a C Series module w...

Страница 21: ...creates symbolic links u v w or x to the media mount point starting with u if it is available To prevent any file corruption to external storage devices verify that any file IO operations with the sp...

Страница 22: ...on accessory kit 158534 01 Module immobilization bracket Installation screws1 M4 x 0 7 button head screw 8 mm M3 x 0 5 flat head screws x2 10 mm Torx T10 T10H driver Torx T20 T20H driver What to Do Co...

Страница 23: ...river Tighten the screw to a maximum torque of 1 3 N m 11 5 lb in 5 Install the two M3 x 0 5 flat head screws from the accessory kit in the top and bottom of the cRIO 9033 using the appropriate Torx T...

Страница 24: ...surface on a 35 mm DIN rail on a desktop or in a rack Mounting the cRIO 9033 in these or other configurations can reduce the maximum allowable ambient temperature and can affect the typical accuracy o...

Страница 25: ...n 8 6 mm 0 34 in 88 1 mm 3 47 in Figure 10 cRIO 9033 Side Dimensions 53 4 mm 2 10 in 53 4 mm 2 10 in 53 4 mm 2 10 in 53 4 mm 2 10 in 44 0 mm 1 73 in 44 0 mm 1 73 in 44 0 mm 1 73 in 44 0 mm 1 73 in Mou...

Страница 26: ...ules require different cabling clearances For a complete list of cabling clearances for C Series modules visit ni com info and enter the Info Code crioconn Figure 12 cRIO 9033 Cabling Clearance Cablin...

Страница 27: ...tly on a Flat Surface For environments with high shock and vibration NI recommends mounting the cRIO 9033 directly on a flat rigid surface using the mounting holes in the cRIO 9033 What to Use cRIO 90...

Страница 28: ...t exceed 8 mm of insertion into the cRIO 9033 Tighten the screws to a maximum torque of 1 3 N m 11 5 lb in Surface Mounting Dimensions The following figure shows the surface mounting dimensions for th...

Страница 29: ...g plate to the cRIO 9033 using the screwdriver and M4 x 10 screws Tighten the screws to a maximum torque of 1 3 N m 11 5 lb in You must use the screws provided with the NI panel mounting kit because t...

Страница 30: ...9 in 25 4 mm 1 00 in Mounting the cRIO 9033 on a DIN Rail You can use the NI DIN rail mounting kit to mount the cRIO 9033 on a standard 35 mm DIN rail What to Use cRIO 9033 Screwdriver Phillips 2 NI D...

Страница 31: ...he correct depth and thread for the DIN rail clip Clipping the Device on a DIN Rail Complete the following steps to clip the cRIO 9033 on a DIN rail 1 2 1 Insert one edge of the DIN rail into the deep...

Страница 32: ...a rack mounting kit Mounting the Device on a Desktop You can use the NI desktop mounting kit to mount the cRIO 9033 on a desktop What to Use cRIO 9033 Screwdriver Phillips 2 NI desktop mounting kit 77...

Страница 33: ...mm 5 01 in BIOS Configuration Resetting the System CMOS and BIOS Settings The cRIO 9033 BIOS configuration information is stored in a nonvolatile memory location that does not require a battery to pre...

Страница 34: ...OS setup utility to change configuration settings and to enable special functions The cRIO 9033 ships with configuration settings that work for most applications but you can use the BIOS setup utility...

Страница 35: ...nformation BIOS Version and Build Date These values indicate the version of the controller BIOS and the date on which the BIOS was built Embedded Firmware Version This value identifies the built in ha...

Страница 36: ...Stay Off the cRIO 9033 returns to the soft off power state after AC power is restored When set to Turn On the cRIO 9033 powers on when DC power is restored Power Button Off Behavior This setting spec...

Страница 37: ...escriptor Device Power Up Delay in Seconds This setting specifies the number of seconds the POST waits for a USB device or hub to power on This setting is only visible when the Device Power Up Delay i...

Страница 38: ...configurations to boot settings The factory default settings provide the most compatible and optimal configuration Setup Prompt Timeout This setting specifies the number of seconds the system waits f...

Страница 39: ...ect this option Save Changes Changes made to BIOS settings during this session are committed to NVRAM The setup utility remains active allowing further changes Discard Changes Any changes made to BIOS...

Страница 40: ...to the NI Trademarks and Logo Guidelines at ni com trademarks for information on NI trademarks Other product and company names mentioned herein are trademarks or trade names of their respective compan...

Отзывы: