BNC-2111 Installation Guide

14

ni.com

Electromagnetic Compatibility (BNC-2111 with Metal Enclosure Only)

Emissions................................................EN 55011 Class A at 10 m

 

FCC Part 15A above 1 GHz

Immunity ................................................EN 61326:1997 + A2:2001, 

Table 1

EMC/EMI ...............................................CE, C-Tick, and FCC Part 15 

(Class A) Compliant

Note 

For EMC compliance, operate this device with shielded cabling.

CE Compliance

This product meets the essential requirements of applicable European 
Directives, as amended for CE marking, as follows:

Low-Voltage Directive (safety)..............73/23/EEC

Electromagnetic Compatibility
Directive (EMC) .....................................89/336/EEC

Note 

Refer to the Declaration of Conformity (DoC) for this product for any additional 

regulatory compliance information. To obtain the DoC for this product, visit 

ni.com/certification

, search by model number or product line, and click the 

appropriate link in the Certification column.

Where to Go for Support

The National Instruments Web site is your complete resource for technical 
support. At 

ni.com/support

 you have access to everything from 

troubleshooting and application development self-help resources to email 
and phone assistance from NI Application Engineers.

A Declaration of Conformity (DoC) is our claim of compliance with the 
Council of the European Communities using the manufacturer’s 
declaration of conformity. This system affords the user protection for 
electronic compatibility (EMC) and product safety. You can obtain the DoC 
for your product by visiting 

ni.com/certification

. If your product 

supports calibration, you can obtain the calibration certificate for your 
product at 

ni.com/calibration

.

National Instruments corporate headquarters is located at 
11500 North Mopac Expressway, Austin, Texas, 78759-3504. 
National Instruments also has offices located around the world to help 
address your support needs. For telephone support in the United States, 

Содержание BNC-2111

Страница 1: ...osition switch for selecting between floating source and ground referenced analog input signals National Instruments offers two versions of the BNC 2111 With metal enclosure Without metal enclosure bo...

Страница 2: ...NRSE Switch 2 BNC Connectors 3 BNC Center Pin 4 BNC Shield AI GND AI SENSE AI0 AI6 AI12 AI1 AI7 AI13 AI2 AI8 AI14 AI3 AI9 AI15 AI4 AI10 AO0 AI5 AI11 AO1 APFI 0 AO EXT REF BNC 2111 2 3 PFI 13 P1 0 CTR...

Страница 3: ...ons for the BNC 2111 refer to the Specifications section Caution Do not connect the BNC 2111 to any device other than the National Instruments devices listed in the Choosing a Cable section Doing so c...

Страница 4: ...I 6036E NI 6040E NI 6052E DAQPad 6052E NI 6070E DAQPad 6070E PCI MIO 16E 1 PCI MIO 16E 4 PCI MIO 16XE 10 PCI MIO 16XE 50 Table 3 Double 68 Position VHDCI I O Connector 32 AI Channels DAQ Device Connec...

Страница 5: ...Connector Diagram NI 6225 Table 5 100 Pin Female 0 050 D Type I O Connector DAQ Device Connector Diagram NI 6025E NI 6031E 6033E NI 6071E BNC 2111 SHC 68 68 Cable BNC 2115 or other accessory SHC 68 6...

Страница 6: ...floating signal source is not connected to the building ground system but has an isolated ground reference point Some examples of floating signal sources are outputs of transformers thermocouples bat...

Страница 7: ...modes by using the Coupling Input Config control of the AI Config VI or by using the appropriate function for your ADE 6 Connect the field signals to the BNC connectors Refer to the Connecting Signal...

Страница 8: ...als Connecting Analog Input Signals Measuring Floating Signal Sources To measure floating signal sources move the selector switch to the floating source switch position labeled RSE When the selector s...

Страница 9: ...e Figure 2 BNC 2111 Signal Source Types Figure 3 AI Channels 0 15 Connections Signal Source DAQ Device AI GND AI GND Signal Source DAQ Device AI GND AI SENSE Floating Source Ground Referenced Source A...

Страница 10: ...C connector AO Channels 0 1 Use the BNC connectors to connect or access PFI signals on your DAQ device Figure 4 shows these connections Refer to Table 6 in the Specifications section for more informat...

Страница 11: ...connected DAQ board The PFI signals can be accessed on the center pin of the applicable BNC connector while digital ground analog output ground for APFI 0 can be accessed on the outer shield of the BN...

Страница 12: ...28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 NC No Connect E Series NC CTR 0 OUT NC D GND NC NC D GND NC D GND NC PFI 0 A...

Страница 13: ...connectors 24 Environment Operating temperature 0 to 55 C Storage temperature 55 to 125 C Relative humidity 5 to 90 noncondensing Altitude 2 000 m Pollution Degree 2 Indoor use only Safety The BNC 211...

Страница 14: ...the Certification column Where to Go for Support The National Instruments Web site is your complete resource for technical support At ni com support you have access to everything from troubleshooting...

Страница 15: ...26 00 Finland 385 0 9 725 725 11 France 33 0 1 48 14 24 24 Germany 49 0 89 741 31 30 India 91 80 51190000 Israel 972 0 3 6393737 Italy 39 02 413091 Japan 81 3 5472 2970 Korea 82 02 3451 3400 Lebanon...

Страница 16: ...onal Instruments trademarks Other product and company names mentioned herein are trademarks or trade names of their respective companies For patents covering National Instruments products refer to the...

Отзывы: