Getting Started with NI Integrated Steppers and NI 73xx Motion Controllers
|
© National Instruments
|
21
UMI-7764 and NI ISM-74xx Configuration and
Installation
This section covers the hardware setup for the NI UMI-7764 and NI ISM-74xx integrated
steppers.
Step 1: Connect and Configure the NI UMI-7764
Complete the following steps to connect and configure your UMI-7764.
Tip
For more information about connecting external power, encoders, and other
motion I/O signals, refer to the
Universal Motion Interface (UMI)-7764 User Guide
and Specifications
.
1.
Connect the SH68-C68-S 68-pin shielded cable between the Motion I/O connector on the
NI 73xx motion controller and the Motion I/O connector on the UMI-7764.
2.
Configure the UMI-7764 DIP switches. You must set the DIP switches to the following
settings to match the polarity configuration for the integrated steppers:
•
Inhibit Input (S2)—Active Low
•
Inhibit Output (S1)—Active Low
The UMI-7764 DIP switch configuration is shown in Figure 12.
Figure 12.
UMI-7764 Inhi
b
it Input and Inhi
b
it Output DIP Switch Settings
3.
Connect an ex5 V power supply to the UMI-7764 Power Input Terminal Block. This
connection is required to power the encoder circuitry that converts differential encoder
signals to single-ended signals for the motion controller, as well as to power the UMI-7764
Inhibit Output signals.
1
Inhi
b
it Input Polarity Switch (S2)
2
Inhi
b
it Output Polarity Switch (S1)
BP4
BP3
BP2
BP1
GND
+5 V
TRIG4
TRIG3
TRIG2
TRIG1
ASSY1
8
6343A-01
UMI-7764
FWDLIM1
HOME1
REVLIM1
AXIS1
FWDLIM3
HOME3
REVLIM3
AXIS3
AIGND
AREF
AIN4
AIN3
AIN2
AIN1
FWDLIM2
HOME2
REVLIM2
AXIS2
FWDLIM4
HOME4
REVLIM4
AXIS4
GND
NC1
SHUTDO
WN
INH ALL
S2 S1
ACTIVE HIGH
LO
W
1
2