background image

NI 653X Cable Adapter User Guide

6

ni.com

Connecting Signals

The NI 653x

 

cable adapter provides connectivity to up to 32 of the 

single-ended DIO channels of an NI high-speed DIO device. Each DIO, 
PFI, and clock channel of the NI high-speed DIO device connects to a 
corresponding pin on the NI 653x cable adapter. The 32 DIO channels are 
directly connected between the two bulk connectors. PFI <0..5> from the 
NI 6535/6535B, NI 6536/6536B, and NI 6537/6537B VHDCI connector 
are connected to a 6-position screw terminal. PFI <0..7> from the 
NI 6533/6534 68-pin DAQ connector are connected to an 8-position screw 
terminal.

PFI channels must be manually connected through screw terminals for 
flexibility and to ensure correct signal routing. You can make connections 
between the PFI channels using 22- to 26-gauge wire. 

The NI 6533/6534 devices have specific applications for PFI channels and 
thus require custom wiring to be compatible. An example of how to make 
these connections is provided in the 

NI 6535/6536/6537 or 

NI 6535B/6536B/6537B Custom Wiring Example

 section.

Содержание 653 Series

Страница 1: ...patible with the NI 654x and NI 655x digital pattern generator analyzer devices For best signal integrity NI recommends using the NI 6535 6536 6537 and 6535B6536B 6537B devices with newer accessories...

Страница 2: ...familiarize you with different aspects of the device The titles and location of the documents vary based on the driver that supports the NI device but you should have the following types of documenta...

Страница 3: ...1 NI 653x Cable Adapter Parts Locator Diagram 1 Enclosure Base 2 Jacksockets M2 5 Screw 2 56 Socket 3 68 Pin DAQ Connector 4 Enclosure Top Cover 5 M2 5 6 mm Phillips Flathead Countersunk Screws 6 Term...

Страница 4: ...ot liable for damage resulting from improper connections Refer to Figure 2 as you complete the following steps to install the cable adapter 1 Insert the cable into the cable adapter 2 Tighten the cabl...

Страница 5: ...enclosure complete the following steps 1 Remove the screws from the cable adapter enclosure top cover as shown in Figure 3 Figure 3 Remove Screws from the Enclosure 2 Remove the enclosure top cover No...

Страница 6: ...36B and NI 6537 6537B VHDCI connector are connected to a 6 position screw terminal PFI 0 7 from the NI 6533 6534 68 pin DAQ connector are connected to an 8 position screw terminal PFI channels must be...

Страница 7: ...NI 653x cable adapter Figure 4 NI 653x Signal Connections Note Refer to the help file for your device for information about the number of available DIO channels on your device DIO 20 31 or PFI_0 may n...

Страница 8: ...68 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 DIO 31 GND DIO 29 GND DIO 27 GND DIO 25 RESERVED DIO 23 GND DIO 21 GND DIO 19 GND DIO 17 GND DIO 15 GND...

Страница 9: ...39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 5 V PFI 2 PFI 6 PFI 0 PFI 4 PFI 5 PFI 1 PFI 7 PFI 3 P0 0 GND P0 3 P0 4 GND P0 7 P1 0 P1 1 GND R GND GND P1 6...

Страница 10: ...7 P1 0 7 P2 0 7 or P3 0 7 on a 68 pin DAQ connector PFI 0 5 Programmable functional interface PFI channels 0 through 5 6 position screw terminal J4 GND Ground reference for signals RESERVED These cha...

Страница 11: ...d with the NI high speed DIO device NI is not liable for any damage resulting from such signal connections Table 3 shows the relationship between PFI channels and the termination sockets Note Refer to...

Страница 12: ...e compatibility between an NI 6533 6534 and an NI 6535 6536 6537 or NI 6535B 6536B 6537B where the fixture is configured to work with the NI 6533 6534 Without changing the fixture setup the adapter an...

Страница 13: ...g table A burst handshaking example using the NI 6533 6534 can be coded in LabVIEW as shown in Figure 8 Figure 8 NI 6533 6534 Burst Handshaking Application Table 4 Example Connections VHDCI NI 6535 65...

Страница 14: ...he NI 653x cable adapter connections and provide compatibility with the previous application using an NI 6535 6536 6537 or an NI 6535B 6536B 6537B instead of an NI 6533 6534 Figure 9 NI 653x Burst Han...

Страница 15: ...mm 2 47 2 73 0 66 in I O connectors 68 pin VHDCI connector 6 position screw terminal 8 position screw terminal 68 pin DAQ connector Recommended wire gage 22 26 AWG Recommended torque for screw termina...

Страница 16: ...ource for technical support At ni com support you have access to everything from troubleshooting and application development self help resources to email and phone assistance from NI Application Engin...

Отзывы: