Safety
8
RECOMMENDED ELECTRICAL PRACTICES—CONTINUED
Single-Phase Equipment
Max
Length
100V Supply
20ft (6m)
40ft (12m)
60ft (20m)
80ft (25m)
120V Supply
25ft (7.5m)
50ft (15m)
75ft (25m)
100ft (30m)
230V Supply
50ft (15m)
100ft (30m)
150ft (45m)
200ft (60m)
Max Amps
Minimum Wire Size
8
16 AWG (1.5mm
2
) 16 AWG (1.5mm
2
) 14 AWG (2.5mm
2
)
12 AWG (4mm
2
)
10
16 AWG (1.5mm
2
) 14 AWG (2.5mm
2
)
12 AWG (4mm
2
)
12 AWG (4mm
2
)
12
14 AWG (2.5mm
2
) 14 AWG (2.5mm
2
)
12 AWG (4mm
2
)
10 AWG (6mm
2
)
14
14 AWG (2.5mm
2
)
12 AWG (4mm
2
)
12 AWG (4mm
2
)
10 AWG (6mm
2
)
16
12 AWG (4mm
2
)
12 AWG (4mm
2
)
10 AWG (6mm
2
)
10 AWG (6mm
2
)
18
12 AWG (4mm
2
)
12 AWG (4mm
2
)
10 AWG (6mm
2
)
8 AWG (10mm
2
)
20
12 AWG (4mm
2
)
12 AWG (4mm
2
)
10 AWG (6mm
2
)
8 AWG (10mm
2
)
25
12 AWG (4mm
2
)
10 AWG (6mm
2
)
8 AWG (10mm
2
)
8 AWG (10mm
2
)
30
10 AWG (6mm
2
)
10 AWG (6mm
2
)
8 AWG (10mm
2
)
6 AWG (16mm
2
)
Single-Phase Equipment
Max
Length
100V Supply
100ft (30m)
120ft (35m)
140ft (40m)
160ft (48.5m)
120V Supply
125ft (40m)
150ft (45m)
175ft (50m)
200ft (61m)
230V Supply
250ft (75m)
300ft (90m)
350ft (105m)
400ft (122m)
Max Amps
Minimum Wire Size
8
12 AWG (4mm
2
)
10 AWG (6mm
2
)
10 AWG (6mm
2
)
10 AWG (6mm
2
)
10
10 AWG (6mm
2
)
10 AWG (6mm
2
)
8 AWG (10mm
2
)
8 AWG (10mm
2
)
12
10 AWG (6mm
2
)
8 AWG (10mm
2
)
8 AWG (10mm
2
)
8 AWG (10mm
2
)
14
8 AWG (10mm
2
)
8 AWG (10mm
2
)
8 AWG (10mm
2
)
6 AWG (16mm
2
)
16
8 AWG (10mm
2
)
8 AWG (10mm
2
)
6 AWG (16mm
2
)
6 AWG (16mm
2
)
18
8 AWG (10mm
2
)
8 AWG (10mm
2
)
6 AWG (16mm
2
)
6 AWG (16mm
2
)
20
8 AWG (10mm
2
)
6 AWG (16mm
2
)
6 AWG (16mm
2
)
6 AWG (16mm
2
)
25
6 AWG (16mm
2
)
6 AWG (16mm
2
)
4 AWG (25mm
2
)
4 AWG (25mm
2
)
30
6 AWG (16mm
2
)
4 AWG (25mm
2
)
4 AWG (25mm
2
)
4 AWG (25mm
2
)