background image

10

3

ABOUT THE SIMULATOR

The 

Life

/

form

®

 “Airway Larry” Airway Management Trainer with Stand is a realistic simulator available 

for the training of intubation and other airway management skills. The airway management trainer is 

anatomically correct in respect to both size and detail. Landmarks include nostrils, teeth, tongue, oral 

and nasal pharynx, larynx, cricoid ring, epiglottis, arytenoid, false and true vocal cords, trachea, and 

esophagus.
Nasco’s “Airway Larry” allows you to practice oral, digital, and nasal intubation. E.T., E.O.A., P.T.L.®, 

L.M.A., E.G.T.A., Combitube®, and King System insertion can all be practiced as well. Suction techniques 

and proper cuff inflation can also be performed and evaluated.
In addition, this model also allows students to apply cricoid pressure during the intubation procedure 

(Sellick’s Maneuver). By locating the larynx and depressing the cricoid ring, the student may realistically 

lower the vocal cords farther into the field of view. This also effectively closes off the esophagus of the 

simulator.
Use your new “Airway Larry” Airway Management Trainer with Stand as a stand-alone trainer, or as a 

replacement head for any 

CP

A

R

LENE

®

 or Adult 

CR

i

S

is

 full body manikin or torso. With proper care, 

your 

Life

/

form

® 

Airway Management Trainer will provide years of valuable service. Please review the 

instructions carefully for setup, cleanup, and maintenance procedures.

LIST OF COMPONENTS

A. 

“Airway Larry” Airway Management  

Trainer on Stand

B. 

8-oz. Bottle of Lubricant

C. 

Left and Right Simulated Lungs

D. 

Simulated Stomach

E. 

3 Red Caps

F. 

Hard Carry Case

F.

A.

C.

E.

B.

D.

Figure 14

8. 

Now pick the head up, hold it in a vertical position, 

and pull the caps from the bronchi to completely 

empty the system. 

(See Figure 14.)

9. 

Rinse the airway, following the same procedure 

used to clean, with warm tap water only. Repeat 

this process until all the soap has been flushed from 

the system.

C. Disinfecting the Airway 

To disinfect, repeat the standard cleaning procedure with a bleach solution, as specified by the Centers 

for Disease Control.

1. 

Fill the system with the solution until it reaches the corners of the mouth. Remember to start filling 

with the head flat and finish with the neck slightly elevated to ensure that the solution completely fills 

all airway passages.

2. 

Once completely filled with the bleach solution, allow the head to sit for at least 10 minutes.

3. 

Drain as previously described and repeat the rinsing process to flush out all of the bleach solution. 

Set the head aside and allow it to air dry completely prior to next use or storage.

CAUTIONS

• 

 Do not place simulator in contact with any printed paper or plastic. The ink will transfer and cause 

an indelible stain. Similar inks, such as ballpoint pen, will also cause an indelible stain.

• 

 Do not use Nasco Cleaner (LF09919U) around the nose or mouth of the simulator. The cleaner 

may be toxic if ingested.

• 

 Properly lubricate the Airway Management head and intubation appliances.

• 

 Use only Nasco Pump Spray Lubricant (LF03644U) with this simulator. Other lubricants, such as 

silicone oil, may cause damage to the airway of the simulator.

• 

 Ensure intubation appliances are used accordingly. Improper use of intubation appliances could 

damage the airway of the simulator. Damage to the airway will require the product to be returned 

to Nasco for repair.

HC190001INM27.indd   5-6

2/21/19   2:52 PM

Содержание Life/form Airway Larry

Страница 1: ...HEALTHCARE AirwayLarry Airway ManagementTrainer LF03699U INSTRUCTION MANUAL WARNING Products may contain dry natural rubber 5 Year Warranty n ...

Страница 2: ...SUPPL LF036 LF036 LF036 LF037 LF036 LF099 Actual supplie ...

Страница 3: ...so allows students to apply cricoid pressure during the intubation procedure Sellick s Maneuver By locating the larynx and depressing the cricoid ring the student may realistically lower the vocal cords farther into the field of view This also effectively closes off the esophagus of the simulator Use your new Airway Larry Airway Management Trainer with Stand as a stand alone trainer or as a replac...

Страница 4: ...intubation This simulator allows for the Sellick s Maneuver of applying cricoid pres sure during intubation procedures Ensuring the cuff is properly deflated prior to removal will prolong the useful life of your simulator Damage caused by improper use of the simulator will not be covered under the warranty 1 Determine the method of intubation 2 Select the appropriate sized intubation appliance 3 G...

Страница 5: ...g the Airway Larry Airway Management Trainer Head to a Torso Nasco s Airway Larry Airway Management Trainer has the ability to be attached to CPARLENE Adult CRiSis Torsos and Manikins and Life form Airway Management Trainer Stands Replacing Head of CPARLENE with Airway Larry Airway Management Trainer Head 1 See Procedure C to remove the Airway Larry head from stand 2 Remove the chest skin chest pl...

Страница 6: ...the back of the neck slide under the ring and into the top of the torso See Figure 6 Figure6 6 Connect the CPARLENE Airway to the Airway Larry Airway Management Trainer Head by first connecting the remaining upper airway corrugated tubing system to the left bronchus 7 Use two of the supplied red caps to plug the right bronchus and esophagus See Figure 7 8 Replace the longer exhaust tubing portion ...

Страница 7: ...may inhibit chest rise during proper ventilation Figure9 Figure10 Figure11 Replacing Head of Adult CRiSis Manikins with Airway Larry Airway Management Trainer Head 1 See Procedure C to remove Airway Larry head from stand 2 Remove the chest skin and chest plate of your Adult CRiSis manikin or torso Note Caution should be taken not to damage electronics during disassembly 3 Disconnect the lung bags ...

Страница 8: ...r Head by using the same method used to remove the head only in reverse When inserted at the shoulders tip the head upward slightly until the two keyways on the back of the neck slide under the ring and into the top of the torso See Figure 6 10 Replace the corrugated bronchus tubes See Figure 12 11 Replace the stomach tube into the esophagus and tighten the pinch clamp See Figure 12 inset 12 Repla...

Страница 9: ...methods previously described Also remove the lungs and stomach 2 Take the trainer to an area with a sink and open counter space Using the red caps supplied plug the right and left bronchi and the esophagus See Figure 13 3 Stabilize the head on the counter face up towels work well for this with plugged tubes hanging over the sink 4 Carefully pour warm soapy water a mild dish soap works best into th...

Страница 10: ...assages 2 Once completely filled with the bleach solution allow the head to sit for at least 10 minutes 3 Drain as previously described and repeat the rinsing process to flush out all of the bleach solution Set the head aside and allow it to air dry completely prior to next use or storage CAUTIONS Do not place simulator in contact with any printed paper or plastic The ink will transfer and cause a...

Страница 11: ...mp Spray Lubricant LF03735U Mounting Kit for Airway Larry Airway Management Head LF03681U Hard Carry Case for Life form Airway Trainers with Stand LF09919U Nasco Cleaner Actual product may vary slightly from photo Nasco reserves the right to change product color materials supplies or function as needed ...

Страница 12: ...F03632U Child Intraosseous Infusion Femoral Access Leg on a Stand LF03633U Child Airway Management Trainer Torso LF03693U Basic Buddy CPR Manikin LF03709U Infant CRiSis Manikin LF03720U Baby Buddy Infant CPR Manikin LF03750U Bariatric CPR Manikin LF03760U Airway Management Cricoid Pressure Trainer LF03770U Chest Tube LF03953U CRiSis Manikin Complete LF03955U Deluxe CRiSis Manikin LF03956U Deluxe P...

Отзывы: