background image

      Advanced “Airway Larry” 

              

              

TORSO MANIKIN

LF03960U

INSTRUCTION MANUAL

                Products by Nasco

Other Available                Simulators

LF00698U 

Adult Injectable Arm (White) 

LF00856U

  Female Catheterization

 

LF00901U

  Prostate Examination 

LF00906U

  Ostomy Care

 

LF00929U

  Surgical Bandaging 

LF00957U

  Enema Administration 

LF00958U

  Pediatric Injectable Arm 

LF00961U

  Intramuscular Injection 

LF00984U

  Breast Examination 

LF00995U

  Arterial Puncture Arm 

LF00997U

  Adult Injectable Arm (Black) 

LF00999U

  Pediatric Injectable Head 

LF01008U

  Intradermal Injection Arm 

LF01012U

  Heart Catheterization (TPN) 

LF01019U

  Ear Examination 

LF01020U

  Supplementary Ear Set 

LF01025U

  Male Cath-Ed I 

LF01026U

  Female Cath-Ed II 

LF01027U

  Peritoneal Dialysis 

LF01028U

  Suture Practice Arm 

LF01036U

  Spinal Injection 

LF01037U

  Hemodialysis Arm 

LF01062U

  Pelvic, Normal & Abnormal 

LF01063U

  Stump Bandaging, Upper 

LF01064U

  Stump Bandaging, Lower 

LF01069U

  Cervical Effacement 

LF01070U

  Birthing Station 

LF01082U

  Cricothyrotomy 

LF01083U

  Tracheostomy Care 

LF01084U

  Sigmoidoscopic 

 

Examination 

LF01087U

  Central Venous Cannulation 

LF01095U

  Blood Pressure Arm 

LF01108U

  Intraosseous Infusion 

 

Simulator 

LF01121U

  Advanced IV Arm 

LF01139U

  Advanced IV Hand 

LF01142U

  Auscultation Trainer

LF01162U

  Venatech IV Trainer 

LF03000U

 

CP

A

R

LENE

®

 

Series 

LF03601U

  Adult Airway Management 

 

Trainer 

LF03602U

  Adult Airway Management 

 

on Manikin 

LF03603U

  Adult Airway Management 

 

Head Only 

LF03609U

  Child Airway Management 

 

Trainer

LF03610U 

Child Airway Management

 

Trainer Head Only

LF03611U 

Child Defibrillation Chest

 

Skin

LF03612U 

Child IV Arm

LF03613U

  Child Blood Pressure Arm

LF03614U

  Child Intraosseous Infusion/

 

Femoral Access Leg Only

LF03615U

  Complete Child

 

CR

i

S

is

 

 

Update Kit

LF03616U

  Child 

CR

i

S

is

 Manikin

LF03617U

  Deluxe Child 

CR

i

S

is

 

 

Manikin with Arrhythmia Tutor

LF03620U

  PALS Update Kit

LF03621U

  Infant Airway Management

 

Trainer Head Only

LF03622U

  Intraosseous Infusion Right

 

Leg

LF03623U

  Infant Airway Management

 

Trainer

LF03626U

  Child Femoral Access 

 

Injection Pad Replacement

LF03632U

  Child Intraosseous Infusion/

 

Femoral Access Leg on a 

 

Stand

LF03633U

  Child Airway Management 

 

Trainer with Torso

LF03693U 

Basic Buddy

 CPR Manikin

LF03699U 

“Airway Larry” Airway 

 

Management Trainer

LF03720U 

Baby Buddy

 Infant CPR Manikin

LF03953U 

CR

i

S

is

 Manikin

LF03955U 

Deluxe 

CR

i

S

is

 Manikin

LF03965U 

Deluxe “Plus” 

CR

i

S

is

 Manikin

LF04001U 

GER

i

 Nursing Manikin

LF04020U

 

KER

i

 Nursing Manikin

LF04021U 

KER

i

 

Basic Manikin

LF04022U

 

KER

i

 Advanced Manikin

LF04030U

 

GER

i

 Advanced Manikin

LF04040U

 

GER

i

 Basic Manikin

LF06001U 

CPR Prompt™

 Adult/Child  

 

Manikin

LF06012U 

CPR Prompt™

 Infant Manikin

LF06200U 

CPR Prompt™

 Keychain  

 

Rescue Aid

LF06204U 

CPR Prompt™

 Rescue and  

 

Practice Aid

901 Janesville Avenue, P.O. Box 901

Fort Atkinson, Wisconsin 53538-0901

1-800-558-9595

www.eNasco.com • E-mail: [email protected]

COPYRIGHT © 2006 PRINTED IN U.S.A   NP 154-06/RV 8-07

Fort Atkinson

NP 154-06 LF03960.indd   1

3/26/08   11:05:45 AM

Содержание CRiSis LF03960U

Страница 1: ...Advanced Airway Larry TORSO MANIKIN LF03960U INSTRUCTION MANUAL Products by Nasco kin n ...

Страница 2: ...rranty only if CRiSis products have been serviced properly as directed in the operating manual Nasco will not be responsible for damage caused by unauthorized repairs or modifications that have been made or if the product has been damaged through misuse accident or abuse This warranty does not cover wear and tear or expend ables such as batteries lubricant and replacement lungs There are no other ...

Страница 3: ...years of valu able service Cleaning Normal surface soil can be removed from the trainer with mild soapy water Stubborn stains may be removed with REN Cleaner W09919U Simply apply the REN Cleaner to the soiled area and wipe clean with a soft cloth Note Avoid using cleaner around the mouth area if students will be apply ing direct mouth to mouth resuscitation techniques as the cleaner may be toxic i...

Страница 4: ...ral digital and nasal intubation E T E O A PTL LMA and Combitube insertion can all be practiced as well please see Using the Combitube Suction tech niques and proper cuff inflation can also be performed and evaluated Lubrication Before using the Advanced Airway Management Trainer Torso lubricate both the simulator and supplies being used with the Nasco lubricant provided See figures 1 2 Note Nasco...

Страница 5: ...then lift off the plate Disconnect the lungs from the bronchi by pulling the red caps from the white connectors See figure 6 Now that the head has been disconnect ed from the airway rotate it 180 so that it is facing backwards The large tab on the front of the neck should be aligned with the keyway in the torso Tilt the head upward until it snaps free See figure 7 Disengage the smaller rear tabs f...

Страница 6: ... with the neck slightly elevated to ensure that the solution completely fills all airway passages Once completely filled with the bleach solution allow the head to sit for at least 10 minutes Drain as described earlier and repeat the rinsing process to flush out all of the bleach solution Set the head aside and allow it to dry completely Using the Combitube Thoroughly read and follow the instruc t...

Страница 7: ...plate back over the upper compression plate and lungs 6 Reattach the chest skin by adjusting the Velcro edges Again be care ful not to damage the electronics attached to the chest skin Torso Set Up A Connecting the Airway 1 The manikin s airway has been dis connected to prevent damage dur ing shipping To connect the airway remove the chest skin chest plate compression springs and upper compression...

Страница 8: ...ators This is possible via the stan dard four lead snap cable Figure 1 If your patient simulator has only two out put posts the red and black leads must be connected to the patient simulator You may want to connect the manikin to the simulator that came with your defibrillator If your patient simulator doesn t have the standard snap connec tors it will be necessary to purchase the corresponding ad...

Страница 9: ...m the manikin Solution 1 Check your connections on the patient simulators one or more may be disconnected 2 Check to make sure your patient simulator is plugged in and working properly Problem ECG wave is inverted Solution Recheck the position of the red and black lead snaps on the patient simulator Note If the defibrillation skin is not functioning or wiring comes undone please contact us to repa...

Страница 10: ...anagement Head Only LF03609U Child Airway Management Trainer LF03610U Child Airway Management Trainer Head Only LF03611U Child Defibrillation Chest Skin LF03612U Child IV Arm LF03613U Child Blood Pressure Arm LF03614U Child Intraosseous Infusion Femoral Access Leg Only LF03615U Complete Child CRiSis Update Kit LF03616U Child CRiSis Manikin LF03617U Deluxe Child CRiSis Manikin with Arrhythmia Tutor...

Отзывы: