4. USING THE HEATER
ALWAYS INSPECT THE STEAM ROOM, BEFORE SWITCHING
ON THE HEATER!
- The heater’s control switch is located in the front at the lower
part of the heater (see Fig. 6).
4.1 Overview
- The heater is switched on and off by toggling the I/O button.
- The SET button is used for setting the following parameters:
Preset timing, power-on time and temperature.
- The setting is carried out using the +/- buttons.
During set-up, an LED flashes to indicate the parameter being set,
with the respective value being displayed on the screen.
- The settings of the power-on time and the temperature
remain in memory even after a short outage of power.
After a longer outage of power, the times are reset to
their default values. The preset timing will always be
reset after use.
- The On/Off LED is illuminated red whenever the heating
elements are turned on; at all other times it is illuminated
green. During the preset time, the On/Off LED is not illuminated.
4.2 Temperature
- The temperature of the sauna at the display is shown on
the display.
- The temperature can be selected at intervals of one degree
from the range 60°C-115°C.
- When setting the temperature, the temperature saved in the
memory, will be displayed first, and after that will be displayed
the temperature that is being set via the +/- buttons.
Figure 6.
Figure 7.
On/Off signal light
Preset timing (yellow)
Power-on
time (green)
Temp. (red)
SET
4.3 Preset timing
- The yellow LED glows when the preset timing is active. The remaining time to switch-on of the
heater is shown on the display.
- Once this time has elapsed, the heater will be switched on, and the On/Off LED will start glowing red.
- The preset time will not be saved in the memory, but will reset to zero after use.
- When the preset time is being set, the yellow LED flashes. At first, the timing is staggered by
intervals of 30 minutes and after that by an hour.
4.4 Power-on time
- The remaining power-on time is shown on the display.
- At first the timing is staggered by15 minutes and after that by half an hour.
4.5 Power-on
- When the heater is switched on, the temperature of the sauna is showed on the display.
- Optionally, the display can be set to show the remaining power-on time or to alternate between
the time and the temperature - see the point Settings.
- As soon as the heater reaches the predetermined temperature, the On/Off LED starts glowing
green, and the elements will not be powered.
- Once the heater has cooled down to such an extent that the elements will be powered again,
the On/Off LED will again glow red.
- The heater remains operational if the power outage lasts less than three minutes. When the power
supply resumes after a power outage of less than three minutes, the heater will resume its operation
from the point where it was before the outage. If the outage lasts longer than three minutes, the
heater is switched off. The settings will always stay in the memory despite duration of the outage.
Содержание NC Series
Страница 2: ......
Страница 41: ...3 3 80 60 3 2 3 5 15 3 0 10 3 4 4 2 4 3 5 5 10 5 5 2 1 2 2 3 A B P 4 P 5 max 80 cm min 60 cm P 3 P 5 2...
Страница 42: ...4 5 4 1 I O SET ON OFF ON OFF 4 2 60 C 115 C P 6 P 7 ON OFF SET 4 3 ON OFF 30 4 4 15 4 5 ON OFF ON OFF 3 3 3...
Страница 43: ...4 6 1 SET 30 SET SET SET 60 C 115 C SET ON OFF ON OFF I O SET 1 4 7 3 d 1 d 1 d 2 d 3 d 1 d 2 d 3 SET SET 1 d...
Страница 45: ...8 8 1000 500 100 150 7 P 8 min 2 cm A 9 60 80 1 2...
Страница 47: ...11 o opy a o ocy ec c a po a c pco o Er1 Er2 Er3 10k 25 C 1...