GB
INSTALLATION AND OPERATING INSTRUCTIONS
NARVI NC
6kW
NARVI NC
9kW
1. THE ELECTRIC SAUNA HEATER PACKAGE INCLUDES:
1. Heater with control unit
2. Fastening plates and fastening screws
3. Temperature sensor
4. Control unit
5. Installation and operating instructions
2. BEFORE INSTALLATION:
Check the following:
-
The output of the sauna heater (in kW) is correct with respect to the size of the sauna (m
3
).
-
The recommended volume of the sauna for each heater type is presented in the Table 1.
-
If there is uninsulated brick, tile or glass wall surface in the sauna, to the inner volume of the sauna,
add 1.5 m
3
for every 1 m
2
of such wall surface, when selecting the heater with the correct output in
the Table 1.
The volume of the sauna must be within the minimum and maximum values given by Table 1.
Table 1 Installation data for the NARVI NC heater
-
The minimum height of the steam room and the minimum safe distances are defined in the Table 1.
-
Ensure that the surface, to which the attachment plate screws are fixed, is sufficiently firm.
A thin panel alone is not sufficient. Additional studding as a reinforcement behind the panel or
reinforcement irons on top of the panel fastened to the wall studding can make the required
reinforcement.
-
The NARVI NC sauna heaters of 6.0 kW can also be installed in a wall recess, provided that the safe
distances given by Figure 1 are observed.
-
The NARVI NC heater of 9.0 kW must not be installed in a wall recess.
INSTALLATION OF MORE THAN ONE ELECTRIC HEATER IN THE SAUNA IS NOT ALLOWED.
All service operations must be done by professional maintenance personnel.
Electricity supply to the heater must be switched off from the fuse panel
before any service measures.
Heater
model
Capacity
Steam room
Minimum safe distances to the heater
Stone
volume
Connection *)
Volume
Height
At the
side
In the
front
In the
front
To the
ceiling
To the
floor
400 V 3N
Fuses
min max
min
A **)
B **)
C **)
D **)
E **)
kW
m
3
m
3
cm
cm
cm
cm
cm
cm
kg
mm
2
A
NARVI NC
6
6
9
190
5
8
2
115
12
25
5x1,5
3x10
NARVI NC
9
9
15
190
7
10
2
115
12
25
5x2,5
3x16
**) See Figure 1
*) Use a rubber-sheathed cable of type H07RN-F or equivalent
as the connecting cable
TECHNICAL DATA:
- width 435 mm
- depth 315 mm
(incl. wall bracket)
- height 520 mm
- weight 15 kg