background image

7

GB

Yrittäjäntie 14, FI-27230 Lappi  •  tel. +358 0207 416 740  •  fax +358 0207 416 743  •  www.narvi.fi/en

Yrittäjäntie 14, FI-27230 Lappi  •  tel. +358 0207 416 740  •  fax +358 0207 416 743  •  www.narvi.fi/en

3. Installation and 

preheating of the sauna 

heater

3.1 Preheating

Before use and arranging the stones, the sauna heater 
must be heated to remove the protective agents. Any pro-
tective films and stickers must have been removed before. 

Preheating shall be carried out on a non-combustible 
surface and outside

, since paint emits harmful solvents 

and smoke during heating. Use of a connection pipe in-
cluded in the delivery of the sauna heater in the upper joint 
improves draft during preheating. 1-2 fireboxes of wood 
are sufficient for preheating. After preheating and before 
arranging the stones loose cover material should be re-
moved from the stone compartment of the sauna heater 
with a steel brush. In case the external surface of the sauna 
heater is painted, it should not be rubbed or wiped before 
the first heating. The paint of the sauna heater will achieve 
sufficient strength only after the first heating. Do not create 
steam during the first heating.

NB! If the sauna heater is equipped with a water tank 
please check before preheating that the water tank faucet 
and safety plug are installed and that 

the tank is filled 

with clean water.

3.2 Regulation of the height

The legs of the sauna heater are adjustable and can be 
used for levelling the sauna heater and for adjusting the 
height. There must be an air gap of at least 25 mm between 
the sauna heater and the floor. Use a spirit level to check if 
the sauna heater is level.

Figure 6.

 Installation of adjustable legs (additional 

equipment)

3.3 Connection with the stack

The sauna heater can be connected to the smoke flue from 
the top or back of the sauna heater. Seal the unused open-
ing with the supplied cover. The sauna heater comes with 
a short smoke flue connection pipe, which can be used to 

connect the sauna heater’s smoke flue from the back. If the 
connection with the smoke flue is done from the above, a 
Kota connective flue or Kota smoke flue must be used. In 
case of connection from the above, a Kota smoke flue tank 
for heating water or a Kota stone basket can be installed 
around the connective flue.

Do not push the connective flue too deep in the smoke flue, 
because this would hinder the draft. Any leaks in the con-
nective flue also reduce the draft; therefore the connections 
must be sealed with fireproof sealing material. 

Leakage in 

the connective flue causes combustion gases formed 
in the sauna heater to ignite in the flue.

 The connection 

joint of the flue and the sauna heater must be 25 mm. The 
diameter of the connective flue of the sauna heater and the 
height from the floor are shown in clause 

1.1.

Please take into account the clearance distance of the 
modular smoke flue, see the manufacturer’s instructions.

3.4 Installation of a door and changing of the 

opening direction of the door

Figure 7. 

Open the door and raise the hinge pin up so it 

comes out of the bottom hinge barrel. Hold onto the door 
securely and turn the bottom part of the pin and turn the 
bottom end of the pin up enough (2) that you can pull the 
pin down (3) and the pin and door come apart. For instal-
lation proceed in reverse order. First push the upper edge 
of the door in its place and thereafter push the pin through 
the upper eyelet. Thereafter turn the door and pin in their 
places from below and let the pin into the bottom eyelet. 
The pin is correctly installed when the wider areas of the 
pin are facing down. In this case the pin cannot move away 
from its place. 

Door installation is easier when you use long flatnose pli-
ers. When removing and installing the door please take into 
account the higher element (washer) between the hinge 
barrel and the door. Finally also install the bolt located on 
the side of the handle and nut on the upper edge of the 
hatch.

3.5 Sauna heater stones

We recommend that you use Kota olive dolerite stones. 
Natural stones are not suitable to be used as sauna heater 
stones 10–15 cm. Before using the stones, they must be 

Figure 6.

Figure 7.

Содержание Kota Kuru 14

Страница 1: ...Kota Kuru 14 14 VS and 20 sauna heaters Installation user and maintenance instructions version 1 4 Made by NARVI Oy Finland GB...

Страница 2: ...2 GB Yritt j ntie 14 FI 27230 Lappi tel 358 0207 416 740 fax 358 0207 416 743 www narvi fi en...

Страница 3: ...a heater 8 3 1 Preheating 8 3 2 Regulation of the height 8 3 3 Connection with the smoke flue 8 3 4 Installation of a door and changing of the opening direction of the door 8 3 5 Sauna heater stones 8...

Страница 4: ...you lack sufficient knowl edge if you are not allowed to use a sauna because of your health condition or you are under the influence of substances causing intoxication Sauna heaters must not be used...

Страница 5: ...ust be taken into account Ignorance of safety clearances causes a fire hazard If required additional information can be obtained from the regional branch of the rescue board 2 3 1 Structure made of co...

Страница 6: ...heater The sauna heater should be con nected to a separate smoke flue A smoke flue made of bricks must be at least the so called half brick smoke flue 2 5 Ventilation Ventilation of the steam room sh...

Страница 7: ...connection with the smoke flue is done from the above a Kota connective flue or Kota smoke flue must be used In case of connection from the above a Kota smoke flue tank for heating water or a Kota sto...

Страница 8: ...ock air openings and stones must not be stacked over the top surface of the sauna heater The recommended quantity of stones in the sauna heater is shown in clause 1 1 The use of stones with a regular...

Страница 9: ...be slippery 4 Using the sauna heater 4 1 Firewood Both hardwood and softwood can be used to heat the sauna heater The use of chipboard fibreboard painted or impregnated wood waste or plastic is prohi...

Страница 10: ...f firewood so that not to damage the smoke flue 4 3 Steam water Use normal domestic water for steam water Quality requirements for domestic water humus content 12 mg l iron content 0 2 mg l calcium co...

Страница 11: ...eater may change colour during heating This is a charac teristic feature of stainless steel and is not covered by warranty The warranty period starts form the moment that the goods are delivered to th...

Страница 12: ...t Back Side Ceiling 250 mm 250 mm 1 350 mm Pass Pass NPD Pass Pass 0 57 Pass 69 12 Pa 13 kW 7 5 kg Pass Pass 370 C Narvi Oy 13 EN 15821 2010 Multi firing sauna stoves fired by natural wood logs for sp...

Отзывы: