background image

3

GB

Yrittäjäntie 14, FI-27230 Lappi  •  tel. +358 0207 416 740  •  fax +358 0207 416 743  •  www.narvi.fi/en

Yrittäjäntie 14, FI-27230 Lappi  •  tel. +358 0207 416 740  •  fax +358 0207 416 743  •  www.narvi.fi/en

1.1 

Technical data 

2.

 

Before you install the sauna heater 

2.1 

Steam room 

2.2 

Substrate 

2.3 

Safety clearances 

2.4 

Smoke flue 

2.5 

Ventilation 

3. 

Installation and preheating  

 

of the sauna heater 

3.1 

Preheating 

3.2 

Regulation of the height 

3.3 

Connection with the smoke flue 

3.4 

Installation of a door and changing of the  

 

opening direction of the door 

3.5 

Sauna heater stones 

8

3.6 

Air flow direction adjusting plates 

 

of a sauna heater 

8

 

4.

 

Using the sauna heater 

4.1 

Firewood 

4.2 

Heating 

4.3 

Steam water 

10

4.4 

Removing the ashes 

10

4.5 

Maintenance of the sauna heater 

10 

4.6 Disposal 

10

5. 

Soot fire 

11

6. 

Frequently Asked Questions 

11

7. Warranty 

11

GB

Content

Содержание Kota Kuru 14

Страница 1: ...Kota Kuru 14 14 VS and 20 sauna heaters Installation user and maintenance instructions version 1 4 Made by NARVI Oy Finland GB...

Страница 2: ...2 GB Yritt j ntie 14 FI 27230 Lappi tel 358 0207 416 740 fax 358 0207 416 743 www narvi fi en...

Страница 3: ...a heater 8 3 1 Preheating 8 3 2 Regulation of the height 8 3 3 Connection with the smoke flue 8 3 4 Installation of a door and changing of the opening direction of the door 8 3 5 Sauna heater stones 8...

Страница 4: ...you lack sufficient knowl edge if you are not allowed to use a sauna because of your health condition or you are under the influence of substances causing intoxication Sauna heaters must not be used...

Страница 5: ...ust be taken into account Ignorance of safety clearances causes a fire hazard If required additional information can be obtained from the regional branch of the rescue board 2 3 1 Structure made of co...

Страница 6: ...heater The sauna heater should be con nected to a separate smoke flue A smoke flue made of bricks must be at least the so called half brick smoke flue 2 5 Ventilation Ventilation of the steam room sh...

Страница 7: ...connection with the smoke flue is done from the above a Kota connective flue or Kota smoke flue must be used In case of connection from the above a Kota smoke flue tank for heating water or a Kota sto...

Страница 8: ...ock air openings and stones must not be stacked over the top surface of the sauna heater The recommended quantity of stones in the sauna heater is shown in clause 1 1 The use of stones with a regular...

Страница 9: ...be slippery 4 Using the sauna heater 4 1 Firewood Both hardwood and softwood can be used to heat the sauna heater The use of chipboard fibreboard painted or impregnated wood waste or plastic is prohi...

Страница 10: ...f firewood so that not to damage the smoke flue 4 3 Steam water Use normal domestic water for steam water Quality requirements for domestic water humus content 12 mg l iron content 0 2 mg l calcium co...

Страница 11: ...eater may change colour during heating This is a charac teristic feature of stainless steel and is not covered by warranty The warranty period starts form the moment that the goods are delivered to th...

Страница 12: ...t Back Side Ceiling 250 mm 250 mm 1 350 mm Pass Pass NPD Pass Pass 0 57 Pass 69 12 Pa 13 kW 7 5 kg Pass Pass 370 C Narvi Oy 13 EN 15821 2010 Multi firing sauna stoves fired by natural wood logs for sp...

Отзывы: