35
W415-1606 / 09.09.16
8.7 LED ON/OFF LIGHT CONTROL
This function will lock the keys to avoid unsupervised operation.
A.
Press the MODE and UP keys at the same time.
B.
To de-activate this function, press the MODE and UP keys at the same
time.
35.10A
76
°F
If the receiver is equipped with batteries they will enable fl ame height control or ON/OFF function to control
the fi replace during a power failure. Refer to “APPLIANCE OPERATION” section when communications
between receiver and transmitter have been lost. The receiver will emit a “beep” sound to confi rm
programming has been successful once power is restored. During a power failure, if the fi replace was on, the
fl ame height will stay at the setting prior to the failure. If off when the failure occurs and then turned on, the
fl ame height will come on at “HI”. The fl ame height can then be controlled by the remote.
35.14A
The life span of the remote batteries depends on various factors: quality of the
batteries, the number of ignitions, etc.
When the transmitter batteries are low, a battery icon will appear on the LCD
display before all battery power is lost. When the batteries are replaced, this icon
will disappear.
When the receiver batteries are low, no “beep” will be emitted from the receiver
when it receives an ON/OFF command. This is an alert for the receiver that there’s
low battery. When the batteries are replaced, the “beep” will be emitted from the
receiver when the ON/OFF key is pressed.
If the batteries of the receiver or transmitter are low, the appliance can be turned on manually by sliding the
three position slider switch on the receiver to the “ON” position. This will bypass the remote control feature
and the appliance main burner will come on if the gas valve is in the “ON” position.
35.13A
76
°F
8.8 CONTINUOUS PILOT / INTERMITTENT PILOT (CPI / IPI) SELECTION
A.
Use the Mode Key to guide you to the CPI mode icon.
Transmitter in the OFF position.
B.
Press the UP/DOWN to switch between IPI and CPI
modes. A single BEEP will confi rm reception of the
command.
NOTE: If the system is equipped with a CPI/IPI toggle
switch, set the CPI/IPI to CPI position to enable remote CPI
operation. If the switch is set to IPI then it will only work in
IPI regardless of what is set on the remote control handset.
35.22
76
°F
IPI
76
°F
CPI
8.9 CHILD PROOF FUNCTION
8.10 LOW BATTERY / MANUAL BYPASS
8.11 IN THE EVENT OF A POWER FAILURE