background image

 

due to weak or broken springs, or being out of balance. 

Frequently  examine  the  installation,  in  particular  check  cables,  springs  and 

mountings  for  signs  of  wear,  damage  or  imbalance.  Do  not  use  if  repair  or 

adjustment is needed since a fault in the installation or an incorrectly balanced door 

may cause injury. 

Each  month  check  that  the  drive  reverses  when  the  door  contacts  a  50  mm  high 

object  placed  on  the  floor.  Adjust  if  necessary  and  recheck  since  an  incorrect 

adjustment  may  present  a  hazard,  for  drives  incorporating  an  entrapment 

protection system depending on contact with the bottom edge of the door. 

Details on how to use the manual release. 

Information concerning the adjustment of the door and drive. 

Disconnect the supply when cleaning or carrying out other maintenance. 

The installation instructions shall include details for the installation of the drive and 

its associated components. 

 
 

Basic function introduction 

1. 

Soft start, soft stop 

Minimize start-up load on garage door opener and garage door

 

2. 

Opening & closing force self-learning

 

3. 

Overloading force detecting

, the door will reverse more than 15 cm automatically when 

it is overloaded when closing. 

4. 

Safety resistance adjustable

, with a wide range, sensitive and reliable. 

5. 

L.E.D light for caution

 

6. 

Wall switch interface available

7. 

Photo beam

, the door will change to open when obstruction is detected while closing. 

8. 

Low-voltage protection

, the process will not perform any action of opening and closing 

when voltage is too low

, door panel and controller won’t be damaged. 

9.  We  adopt 

rolling  code  transmitter

,  with  billions  of  codes, won’t  be  coincident code  or 

pirated code. 

10. 

Back up battery

 interface available, in case of power failure.   

11. 

Keypad

 interface available. 

12. 

With auto-closing feature

13. 

Metal bottom plate, stronger and security.

 

14. 

O/S/C  button

 

B

,  make  adjustment,  maintenance  and  emergent  opening  or  closing 

convenient. (Below picture)   

15. 

External fuse A

. (Below picture)                   

 

 

 

 

 

 

 

 

Содержание SDO1000

Страница 1: ...d the manual carefully before installation and use The installation of your new door opener must be carried out by a technically qualified or licensed person Attempting to install or repair the door o...

Страница 2: ...4 Installation steel track 5 Installation recommendations 6 Basic function setting and applying 7 8 Special function introduction and application 9 10 PCB structure 10 Aluminum steel sectional steel...

Страница 3: ...he garage door is fully open stationary before driving in or out of the garage 7 Make sure the garage door is fully closed stationary before leaving 8 Keep hands and loose clothing off the opener and...

Страница 4: ...associated components Basic function introduction 1 Soft start soft stop Minimize start up load on garage door opener and garage door 2 Opening closing force self learning 3 Overloading force detectin...

Страница 5: ...CHAIN SHUTTLE ASSEMBLY As for the ease of the chain it is delivered with the chain and chain shuttle already assembled in the track If you need to assemble it yourself connect the chain shuttle to th...

Страница 6: ...the doorframe or to the ceiling iron angle F Fig 5 maintaining a minimum gap of 30mm from the top panel s maximum height Fig 6 Check measurements for drilling insert and lock the brackets F and fix th...

Страница 7: ...ron angle Notice Make sure the track is horizontal and vertical to the shaft Make sure the connection of iron angle and ceiling is firm enough 5 The connection of panel bracket and panel connector ref...

Страница 8: ...ay be subject to damage if the control unit is abused 5 Make sure that you have all the necessary materials and they are suitable for this kind of use 6 Read all the instructions thoroughly and make s...

Страница 9: ...ust the down limit by pressing LIM 2 button Fine tuning LIM 1 or LIM 2 button to determine the final down limit position then press set button 4 The opener will operate a cycle automatically to rememb...

Страница 10: ...n the auto close time decrease 1 minute The auto close function will be turned off when LED displays 0 3 Press SET button to confirm 1 Press LIM 2 button and hold on until the LED displays 11 2 Press...

Страница 11: ...he special needs of customers 1 The O S C interfaces available Add another O S C button to open or close the door 2 Auto safety reverse function This special function is for safety consideration Rever...

Страница 12: ...Fig 3 PCB structure...

Страница 13: ...xis pin 1 M8X16 hexagon head bolt 4 M8 flange nut 4 Motor bracket 3 6 90 axis pin 1 M6 20 screw for clutch fix 4 M6 nut M6 pad 4 Aluminum track accessory list Chain Drive Item Quantity Bracket for doo...

Страница 14: ...east twice a year if it is properly balanced and all working parts are in good working condition or not Check the reversing sensitivity at least twice a year and adjust if it is necessary Make sure th...

Страница 15: ...es Important information for the user Once the opener has been installed the user must be informed about how it works and all the risks that can arise if it is used improperly The user must avoid plac...