W415-1476 / C / 10.03.17
10
EN
If possible connect the air intake at the pedestal’s back to outside air with a 4 inch (100mm) diameter fresh
air kit available at your authorized dealer / distributor. Follow detailed instructions under “Mobile Home
Outside Air”.
The following are signs that a fresh air kit may be required:
•
When there is combustion present: Wood burns poorly, smoke spills, back-draft takes place and your
chimney does not draw steadily.
•
In the winter there is too much condensation on the windows.
•
Opening a window seems to alleviate the above symptoms.
•
A ventilation system is installed in the house.
•
Other devices are present that exhaust house air.
•
The house has tight fitting windows and/or is equipped with a well-sealed vapour barrier.
!
WARNING
IF ROOM AIR STARVATION OCCURS BECAUSE THE FRESH AIR INTAKE IS BLOCKED WITH ICE,
LEAVES, ETC., OR BECAUSE THE APPLIANCE DOOR WAS LEFT OPEN, OR DUE TO A STRONG
EXHAUST FAN OPERATING ETC., DANGEROUS FUMES AND SMOKE FROM THE OPERATING
APPLIANCE COULD BE DRAWN INTO THE ROOM.
99.1B
EMBER PROTECTOR:
This appliance must be installed on a non-combustible protector that extends to the front, sides and back of the
appliance as per the minimum requirements below.
NOTE: Ember protection is required for spark and ash shielding, not for limiting fl oor temperatures
from the radiant heat of the appliance. The appliance was designed and safety tested so that without
any protection, the fl oor will not overheat.
J
J
I
L
K
J
J
I
L
MINIMUM FLOOR PROTECTION
FRONT (I)
SIDES (J)
BACK (K)
VENT (L)
CANADA
18” (45.7cm)
8” (203.2mm)
8” (203.2mm)
N/A
USA
16” (40.6cm)
8” (203.2mm)
8” (203.2mm)
2” (50.8mm)
3.3 ALCOVE INSTALLATION
3.4 FLOOR PROTECTION
3.5 OUTSIDE AIR
EN
W415-1468 / A / 09.30.16
9
3.0 PRE-INSTALLATION PREPARATION
Have an authorized dealer install the appliance. If you install the appliance yourself, have your dealer review
your installation plans and/or installation.
Draw out a detailed plan of the installation including dimensions and verify the dimensions with the
requirements listed in this manual.
You may wish to adjust the appliance position slightly to ensure the vent does not intersect with a framing
member. Appliance must be positioned so that no combustibles are within, or can swing within (e.g. drapes,
doors), 4 feet (1.2m) of the front of the appliance.
67.1B
3.1 APPLIANCE PLACEMENT
3.2 CLEARANCE TO COMBUSTIBLES
PARALLEL & CORNER
SINGLE WALL CONNECTOR
DOUBLE WALL CONNECTOR
1100 / 1150 1400 / 1450
1900
1100
1400 / 1450
1900
SIDEWALL (A)
12"
(30.5cm)
12"
(30.5cm)
22"
(55.9cm)
10"
(254mm)
10"
(254mm)
22"
(59.9cm)
SIDEWALL TO FLUE (B)
21"
(53.3cm)
21"
(53.3cm)
21"
(53.3cm)
19"
(48.3cm)
19"
(48.3cm)
19"
(48.3cm)
BACKWALL (C)
10"
(254mm)
12"
(305mm)
12"
(305mm)
6"
(152mm)
6"
(152mm)
12"
(305mm)
BACKWALL TO FLUE (D)
13"
(33cm)
16.5"
(41.9cm)
16.5"
(41.9cm)
9"
(229mm)
9"
(229mm)
16.5"
(41.9cm)
CORNER (E)
6"
(152mm)
6"
(152mm)
8"
(203mm)
2"
(51mm)
4"
(102mm)
8"
(203mm)
CEILING (F)
7 feet
(2.1m)
7 feet
(2.1m)
7 feet
(2.1m)
7 feet
(2.1m)
7 feet
(2.1m)
7 feet
(2.1m)
Clearances can be reduced with shielding acceptable to local authorities. Reduced installation must comply
with NFPA 211 or CAN/CSA-B365.
Clearances are unable to be reduced for the 1150 by using double wall pipe.
14"
23"
ALCOVE
4 FOOT
MAX
9”
6”
1100 series only may be installed, using a listed double wall connector,
such as Security DL6 in Canada, the Simpson Duravent Plus DVL in
the USA or an equivalent double wall connector, into an alcove having
a depth of no more than 4 feet and a height of at least 7 feet (2.1m).
The minimum clearances are as shown.
3.3 ALCOVE INSTALLATION
BACK WALL
B
SIDE WALL
A
BACK WALL
C
SIDE WALL
F
D
E
E
DO NOT INSTALL INTO ANY AREA HAVING A HEIGHT LESS THAN 7 FEET (2.1m)
(CEILING OF ENCLOSURE TO APPLIANCE BOTTOM, EXCLUDING HEARTH HEIGHT)
!
WARNING
S1 and S4 models only may be installed, using a listed double wall
connector, such as Security DL6 in Canada, the Simpson DuraVent Plus
DVL in the USA, or an equivalent double wall connector, into an alcove
having a depth of no more than 4 feet and a height of at least 7 feet
(2.1m). The minimum clearances are as shown.
*
*
* Double wall connector clearances are as per the connector manufacturer’s instructions.
FEET