EN
W415-2007 / A / 10.21.19
31
maintenance
A.
Turn off all electrical power to the appliance.
B.
Remove 4 screws from blower cover and slide the complete assembly forward.
C.
Detach the blower from the blower cover by removing 2 screws in the middle of the blower cover.
D.
When reconnecting electrical connections, ensure that they remain secure.
E.
To reinstall the blower assembly, reverse these steps.
F.
When reinstalling the blower assembly, ensure that the insulation stays in place.
6.10 blower service or replacement
BLOWER COVER
BLOWER
VARIABLE SPEED SWITCH
MICRO SWITCH
THERMAL DISC
FAN
POWER
CORD
THERMODISC
G
FAN-SPEED CONTROL
PRESSURE
SWITCH
POWER
CORD