INDOOR UNDT
1. Determine hole positions according to left and right
side of the installation plate. The hole center is obtained
by measuring the distance as shown in the diagram above.
2. Dirll the piping plate hole with
65mm hole-core drill.
3. Drill the piping hole at either the right or the left and the
hole should be slightly slanted to the outdoor side.
4. Always take steps to protect the pipe when drilling metal
grid,metal plate or the like.
DRILL A HOLE IN THE WALL
INSTALLATION PLATE MOUNTING
2
1
Correct orientation
of Installation Plate
1. Fit the installation plate horizontally on
structural parts of the wall withspaces
around the installation plate.
2. If the wall is made of brick, concrete
or the like, drill five or eight 5mm
diameter holes in the wall. Insert
clip anchor for appropriate mounting
screws.
3. Fit the installation plate on the wall
with five or eight type A screws.
Mount the Installation Plate and drill
holes in the wall according to the wall
structure and corresponding mounting
points on the installation plate. The
installation plate providedwith the
machine differ from appliance
to appliance.(Dimensions are in
mm unless otherwise stated)
NOTE:
NOTE:
"
"
Installation Plate Mounting
The mounting wall is strong and solid enough
to prevent it from the vibration.
45
45
28
0
120mm or
more to wall
120mm or
more to wall
120mm or
more to wall
150mm or more to ceiling
150mm or more to ceiling
Left rear side
refrigerant
pipe hole 65
3
6
.5
835
140
110
Left rear side
refrigerant
pipe hole
65
Right rear side
refrigerant
pipe hole 65
Right rear side
refrigerant
pipe hole 65
Indoor unit outline
Indoor unit outline
120mm or
more to wall
120mm or
more to wall
Indoor unit outline
990
31
5
135
260
150mm or more to ceiling
Left rear side
refrigerant
pipe hole
65
Right rear side
refrigerant pipe
hole 65
Model C
Model D
Model B
Model A
120mm or
more to wall
45
45
3
6
.5
750
180
110
28
0
Right rear side
refrigerant pipe
hole 65
Left rear side
refrigerant
pipe hole
65
150mm or more to ceiling
Installation plate
Indoor unit outline
120mm or
more to wall
120mm or
more to wall
1186
21.5
275
275
34
3
45
4