34
W415-1624 / D / 11.22.16
EN
EN
* Within the appliance enclosure a 6" (152mm) clearance between the top of the vent pipe and combustible
materials is required. All other clearances within the enclosure, including where the vent pipe exits the
enclosure are subject to 2" (51mm) to the sides and bottom and 3" (76mm) to the top for horizontal and 1"
(25mm) for vertical.
** See venting section.
IMPORTANT:
The LV50 requires a minimum inside enclosure height of 75 1/4" (191.1cm) for see-
through and 58” (147.3cm) for single sided, measured from the bottom of the appliance. For temperature
requirements, this area must be left unobstructed. It is also recommended that the enclosure be ventilated
at the top and bottom to circulate the hot air.
Before fi nishing in the appliance test the operation using the remote control, cycling it through all of its
different
modes, see “OPERATION” section. Check pressure readings, see “PILOT BURNER ADJUSTMENT”
section.
Once fi nished in, access to the control components can only be done through the inside of the
appliance.
5.4
MINIMUM CLEARANCE TO COMBUSTIBLE ENCLOSURES
!
WARNING
THE FRONT OF THE APPLIANCE MUST BE FINISHED WITH ANY NON-COMBUSTIBLE MATERIALS
SUCH AS BRICK, MARBLE, GRANITE, ETC., AS LONG AS THESE MATERIALS NEVER OVERHANG
INTO THE APPLIANCE OPENING.
75 1/4"
191.1cm
MINIMUM
ENCLOSURE
HEIGHT
TOP OF
APPLIANCE
OPENING
26 1/2"
67.3cm
MINIMUM
25 3/4"
65.4cm
MINIMUM
COMBUSTIBLE
MATERIAL
NON-COMBUSTIBLE
NON-COMBUSTIBLE
0” IF NON-COMBUSTIBLE
FINISHING IS USED SUCH
AS BRICK AND STONE.
3"
76mm
2"
51mm
65 1/4"
165.7cm
MINIMUM
PLUS RISE**
7" 179mm
TO SIDEWALL
STEEL STUD FRAME
COMBUSTIBLE
TOP OF
ENCLOSURE
NOTE: JOINT COMPOUNDS AND TAPES THAT ARE
RESILIENT TO HEAT AND CRACKING SHOULD BE
USED WHEN TAPING AND MUDDING SEAMS.
6"
152mm *
HEAT SHIELD
SEE-THROUGH