11

W415-1034 /  09.01.11

4.0 FINISHING

Combustible mantel clearance can vary according to the mantel depth. Use the graph to help evaluate the 
clearance needed. These same requirements apply to any combustibles protruding on either side of the appli-
ance.

3

14

5

4

MANTEL DEPTH

0

+

(

,

*

+

7

0

$

1

7

(

/

6

15

16

17

!

WARNING

RISK OF FIRE, MAINTAIN ALL SPECIFIED AIR SPACE CLEARANCES TO COMBUSTIBLES. FAILURE 

TO COMPLY WITH THESE INSTRUCTIONS MAY CAUSE A FIRE OR CAUSE THE APPLIANCE TO 

OVERHEAT. ENSURE ALL CLEARANCES (I.E. BACK, SIDE, TOP, VENT, MANTEL, FRONT, ETC.) ARE 

CLEARLY MAINTAINED.

WHEN USING PAINT OR LACQUER TO FINISH THE MANTEL, THE PAINT OR LACQUER MUST BE 

HEAT RESISTANT TO PREVENT DISCOLOURATION.

73.1

!

WARNING

RISK OF FIRE!

NEVER OBSTRUCT THE FRONT OPENING OF THE APPLIANCE. 

THE FRONT OF THE APPLIANCE MUST BE FINISHED WITH ANY NON-COMBUSTIBLE MATERIALS 

SUCH AS BRICK, MARBLE, GRANITE, ETC., PROVIDED THAT THESE MATERIALS DO NOT GO 

BELOW THE SPECIFIED DIMENSION AS ILLUSTRATED. 

DO NOT STRIKE, SLAM OR SCRATCH GLASS. DO NOT OPERATE APPLIANCE WITH GLASS 

REMOVED, CRACKED, BROKEN OR SCRATCHED. 

FACING AND/OR FINISHING MATERIAL MUST NEVER OVERHANG INTO THE APPLIANCE OPENING.

72.1A

4.1  MINIMUM MANTEL CLEARANCES

14”

17”

16”

15”

6” MANTEL

5”

3”

4”

20

1

/

2

Содержание IR3GN

Страница 1: ...uctions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the supplier This appliance may be installe...

Страница 2: ...T 15 6 2 VENTURI ADJUSTMENT 15 6 3 FLAME CHARACTERISTICS 16 7 0 ELECTRICAL INFORMATION 17 7 1 WIRING DIAGRAM 17 8 0 OPERATION 18 8 1 GENERAL TRANSMITTER LAYOUT 18 8 2 APPLIANCE OPERATION 18 8 3 HAND H...

Страница 3: ...INSTALLATION OVERVIEW Venting see INSTALLATION CHIMNEY CONNECTION section Rating Plate see RATING PLATE INFORMATION section Glass see FINISHING GLASS BURNER INSTALLATION section Media see FINISHING ME...

Страница 4: ...The appliance is a vented gas fired appliance Do not burn wood or other materials in the appliance It is imperative that the control compartments burners and circulating blower and its passageway in...

Страница 5: ...OUND AND ESPECIALLY ABOVE THE APPLIANCE CAN BECOME HOT AVOID CONTACT WHEN THE APPLIANCE IS OPERATING FIRE RISK EXPLOSION HAZARD HIGH PRESSURE WILL DAMAGE VALVE DISCONNECT GAS SUPPLY PIPING BEFORE PRES...

Страница 6: ...ation where the vent will pass through the house without cutting a floor or roof joist If the appliance is installed directly on carpeting vinyl tile or other combustible material other than wood floo...

Страница 7: ...U MAXIMUM SUPPLY PRESSURE 7 0 WATER COLUMN PERSSION D ALIMENTATION MAXIMALE 7 0 D UNE COLONNE D EAU AFUE 63 9 MANIFOLD PRESSURE 10 WATER COLUMN PRESSION AU COLLECTEUR 10 D UNE COLONNE D EAU MINIMUM SU...

Страница 8: ...the backer plates aluminium trim etc but these parts are not to be applied so as to have an airtight seal WARNING RISK OF FIRE MAINTAIN SPECIFIED AIR SPACE CLEARANCES TO VENT PIPE AND APPLIANCE W385 0...

Страница 9: ...th caulking not supplied Fasten to the chimney with screws and plugs not supplied C INSIDE Remove the securing screw from the front of the vent mounting plate Pull the vent mounting plate only back in...

Страница 10: ...vide sufficient movement for shifting the burner assembly on it s side to aid with servicing components F Check for gas leaks by brushing on a soap and water solution Do not use open flame WARNING RIS...

Страница 11: ...DE TOP VENT MANTEL FRONT ETC ARE CLEARLY MAINTAINED WHEN USING PAINT OR LACQUER TO FINISH THE MANTEL THE PAINT OR LACQUER MUST BE HEAT RESISTANT TO PREVENT DISCOLOURATION 73 1 WARNING RISK OF FIRE NEV...

Страница 12: ...ering the burner tube and following the natural shape of the media tray In some installations glass media over the burner tube may cause a Puffing sound If this sound is excessive simply push the medi...

Страница 13: ...ies must be installed into the receiver before operation is possible in the XIR3 The receiver is located in the bottom left corner of the appliance If receiver removal is necessary remove the left acc...

Страница 14: ...E ABSENCE OF LOCAL CODES USE THE CURRENT CSA22 1 CANADIAN ELECTRIC CODE IN CANADA OR THE CURRENT NATIONAL ELECTRIC CODE ANSI NFPA NO 70 IN THE UNITED STATES ALWAYS LIGHT THE PILOT WHETHER FOR THE FIRS...

Страница 15: ...NS D INSTALLATION A CET APPAREIL EST MUNI D UN DISPOSITIF D ALLUMAGE QUI ALLUME LA VEILLEUSE AUTOMATIQUEMENT N ESSAYE PAS D ALLUMER LA VEILLEUSE MANUELLEMENT B AVANT D ALLUMER SENTE L AIR AUTOUR DE L...

Страница 16: ...G on the receiver front cover The receiver will beep three 3 times to indicate that it is ready to synchronize with the transmitter D Install the 3 AAA batteries in the transmitter battery bay located...

Страница 17: ...now displayed B To adjust the set temperature press the Up Down Arrow Keys until the desired set temperature is displayed on the LCD screen of the Transmitter 35 6 76 F ON 68 ROOM TEMPERATURE SET TEM...

Страница 18: ...F ON Hi FLAME OFF FLAME AT LEVEL 1 FLAME AT LEVEL 5 FLAME AT HI LEVEL 6 6 8 FLAME HEIGHT This function will lock the keys to avoid unsupervised operation A Press the MODE and UP keys at the same time...

Страница 19: ...ght will stay at the setting prior to the failure If off when the failure occurs and then turned on the flame height will come on at HI The flame height can then be controlled by the remote 35 14 The...

Страница 20: ...rner turns on and off With the remote control fan speed preset at the preferred speed the blower will come on approximately 5 minutes after the main burner comes on and will shut off approximately 12...

Страница 21: ...column for propane Check that main burner is operating on HI AFTER TAKING PRESSURE READINGS BE SURE TO TURN SCREWS CLOCKWISE FIRMLY TO RESEAL DO NOT OVERTORQUE Leak test with a soap and water solutio...

Страница 22: ...o periodically perform a visual check of the pilot and burner flames Compare them to the illustra tions provided If any flames appear abnormal call a service person FLAME MUST ENVELOP UPPER 3 8 TO 1 2...

Страница 23: ...d bottom of the door is not broken or missing Replace if necessary 8 If for any reason the vent air intake system is disassembled re install and re seal per the instructions provided for the initial i...

Страница 24: ...ON DO NOT STRIKE SLAM OR SCRATCH GLASS DO NOT OPERATE APPLIANCE WITH GLASS REMOVED CRACKED BROKEN OR SCRATCHED 56 1A NOTE Care must be taken when removing and disposing of any broken glass or damaged...

Страница 25: ...in the lamp housing are necessary for ventilation and must not be covered GASKET LENSE FRAME COLOURED SIDE UP 8 6 NIGHT LIGHT REPLACEMENT Your appliance comes equipped with our Night Light The light...

Страница 26: ...ws holding the valve train in place NOTE A new gasket may be required when reinstalling the valve train assembly Contact your local authorized dealer distributor C Carefully lift the valve train assem...

Страница 27: ...DESCRIPTION 14 GDI 226 TERMINAL VENT KITS REF NO PART NO DESCRIPTION 2 3 DOUBLE PLY ALUMINUM LINER INLET AND EXHAUST 15 GDI 320KT VENT KIT 20FT 15 GDI 325KT VENT KIT 25 FT 15 GDI 335KT VENT KIT 35 FT...

Страница 28: ...S9 DELUXE 1 PC SURROUND 30H X48W MATTE BLACK 24 CI3S CAST IRON SURROUND KIT 29H X 46W MATTE BLACK 25 I3CRFK CONTEMPORARY RECTANGULAR FRONT GLOSS BLACK 25 I3CRFHC CONTEMPORARY RECTANGULAR FRONT HAMMERT...

Страница 29: ...29 W415 1034 09 01 11 3 2 1 9 14 22 27 28 25 26 41 28 29 10...

Страница 30: ...3 5 water column for natural gas or 10 water column for propane Check that main burner is operating on HI AFTER TAKING PRESSURE READINGS BE SURE TO TURN SCREWS CLOCKWISE FIRMLY TO RESEAL DO NOT OVER T...

Страница 31: ...ndition and the LED is blinking 3 times using the transmitter ON OFF button Step 1 Turn the system off by pressing the ON OFF button to turn the system off Step 2 After approximately 2 seconds press t...

Страница 32: ...rom pilot hood the circuit is broken A wrong orifice or too high of an inlet pressure can cause the pilot flame to lift The sensor rod may need cleaning Poor grounding between pilot assembly and gas v...

Страница 33: ...plated trim or other components due to water weather damage long periods of dampness condensation damaging chemicals or cleaners will not be the responsibility of NAPOLEON All parts replaced under th...

Страница 34: ...34 W415 1034 09 01 11 12 0 SERVICE HISTORY 43 1...

Страница 35: ...35 W415 1034 09 01 11 12 0 NOTES 44 1...

Страница 36: ...36 W415 1034 09 01 11 44 1...

Отзывы: