![Napoleon HD81 Скачать руководство пользователя страница 6](http://html1.mh-extra.com/html/napoleon/hd81/hd81_installation-and-operating-instructions-manual_3659593006.webp)
6
W415-0712 / B / 09.20.11
It’s important to periodically perform a visual check of the pilot and burner fl ames. Compare them to the illustra-
tions provided. If any fl ames appear abnormal call a service person.
FLAME MUST ENVELOP
UPPER 3/8” TO 1/2” OF
FLAME SENSOR
PILOT
BURNER
ELECTRODE
FLAME
SENSOR
54.1A
Air Shutter Openings both Burners
LP
7/16”
NG
3/16”
3.0 ADJUSTMENT
3.1 FLAME
CHARACTERISTICS
3.2 VENTURI
ADJUSTMENT
This appliance has an air shutter that has been factory set open according
to the chart below:
Regardless of venturi orientation, closing the air shutter will cause a more
yellow flame, but can lead to carboning. Opening the air shutter will cause a
more blue flame, but can cause flame lifting from the burner ports. The
flame may not appear yellow immediately; allow 15 to 30 minutes for the
final flame colour to be established.
AIR SHUTTER ADJUSTMENT MUST ONLY BE DONE BY A QUALIFIED
INSTALLER!
AIR
SHUTTER
OPENING
VENTURI
BURNER
ORIFICE
49.1
Содержание HD81