3
W415-0712 / B / 09.20.11
2.3 BULKHEADS
NOTE: Bulkhead covers need to be removed.
A.
Connect the gas fl ex lines and the pilot line
to the gas bulkheads located under the valve
access opening. Be sure to match up the gas
manifold marked with a painted dot with the
center bulkhead, also marked with a painted
dot. Care must be taken to ensure the pilot
line isn’t damaged and ensuring gas tight
connections are made.
Gas
Bulkheads
Painted
Dots
Pilot
Bulkhead
Pilot
Electrode
Leads
Pilot
Electrode
Venturi
Tube
Orifi ce
B.
Connect the pilot electrode leads to the
bulkhead. The leads can only fi t one way.
You need to match the 1/4” fl ag with the 1/4”
bulkhead spade and the 3/16” fl ag with the
3/16” spade.
C.
Ensure the 2 venturi tubes are over the
orifi ces before lighting.
D.
Check for gas leaks by brushing on a soap
and water solution. Do not use open fl ame.
E.
After leak test has been performed re-install
access panel with gasket.