24
W415-0153 / E / 05.28.12
A.
Attach the adjustable pipe to the last section of rigid pipe.
Secure with screws and seal.
B.
Install the inner
fl
ex pipe to the appliance. Secure with 3 screws
and
fl
at washers. Seal the joint and screw holes using the high
temperature sealant W573-0007 (not supplied).
C.
Run a bead of high temperature sealant (not supplied) around
the inside of the air intake collar. Pull the adjustable pipe a
minimum 2” into the air intake collar.
NOTE: Ensure that the sealant is not visible on the exterior pipes once installation is completed. An
optional decorative black band is available for this use. In the event that the venting must be disassembled,
care must be taken to reseal the venting.
28.3
2” OVERLAP
HIGH TEMPERATURE
SEALANT
#8 X 1/2”
SELF
DRILLING
SCREWS
4.3 APPLIANCE VENT CONNECTION
4.4 MOBILE HOME INSTALLATION - MODEL GDS28
In Canada, mobile home installation may be vented horizontally or vertically. In the United States, it may only
be installed vertically. See "VERTICAL VENTING" or "HORIZONTAL AIR TERMINAL INSTALLATION" section
for installation.
For mobile home installations, the appliance must be fastened in place. It is recommended that the appliance
be secured in all installations. Use the levelling / securing kit, GDSLL-KT for this purpose.