19
W415-0153 / E / 05.28.12
3.10 VERTICAL THROUGH EXISTING CHIMNEY
7.6
This appliance is designed to be attached to a 3” co-linear aluminum
fl
ex vent system running the full length
of a masonry chimney.
The
fl
ex liners accommodate any contours of a masonry chimney, however, it is necessary to keep the
fl
exible
liners as straight as possible. The inlet air collar of the termination cap must be connected to the air intake
fl
ex
liner and the exhaust collar must be connected to
the exhaust
fl
exible liner.
Both Simpson Duravent and Selkirk co-linear
to co-axial adaptors have been approved on
this appliance (
NOTE:
A vent adaptor will be
required directly off the appliance
).
Follow vent manufacturer’s installation
instructions.
Different manufacturer’s venting components
must not be combined. Once the preferred
manufacturer’s appliance adaptor has been
attached, the remainder of the system must
be that of the same manufacturer.
The only exception to this rule is to use Wolf
Steel’s approved 3”
fl
ex liner and co-linear
termination.
!
WARNING
RISK OF FIRE!
CO-AXIAL TO CO-LINEAR VENTING CONFIGURATIONS MUST ONLY BE USED IN A NON-
COMBUSTIBLE CHIMNEY OR ENCLOSURE. INSTALLATION IN A COMBUSTIBLE ENCLOSURE COULD
RESULT IN A FIRE.
AIR
INTAKE
EXHAUST
FLUE
FLEX
LINER
*
40 FT
MAX.
10 FT
MIN
COAXIAL TO
CO-LINEAR
ADAPATER
APPLIANCE
VENT ADAPTOR
TERMINATION
* Measured from appliance
fl
ue collar
to termination
fl
ue collar
Содержание Haliburton GDS28N
Страница 46: ...46 W415 0153 E 05 28 12 12 0 SERVICE HISTORY 43 1 ...
Страница 47: ...47 W415 0153 E 05 28 12 ...
Страница 48: ...48 W415 0153 E 05 28 12 ...
Страница 49: ...44 1 48 W415 0153 C 10 11 11 13 0 NOTES ...