www.napoleongrills.com
12
EN
Leak Testing Instructions
WARNING!
A leak test must be performed annually, or if a part of the gas system is replaced.
WARNING!
Never use an open flame to check for gas leaks. Be certain no sparks or open flames
are in the area while you check for leaks. Sparks or open flames will result in a fire or explosion,
damage to property, serious bodily injury, or death.
Leak testing
:
This must be done before initial use, annually, and whenever any gas components are
replaced or serviced. Do not smoke while performing this test, and remove all sources of ignition. See Leak
Testing Diagram for areas to check. Turn all burner controls to the off position. Turn gas supply valve on.
Brush a half-and-half solution of liquid soap and water onto all joints and connections of the regulator,
hose, manifolds and valves.
Bubbles will indicate a gas leak. Either tighten the loose joint or have the part replaced with one
recommended by the Napoleon Customer Solutions department and have the appliance inspected by a
certified gas installer.
If the leak cannot be stopped,
immediately shut off the gas supply,
disconnect it, and have the grill
inspected by a certified gas installer or dealer. Do not use the appliance until the leak has been corrected.
Manual Gas
Valve (on/off)
Burner Assembly
Cylinder Retaining
Bracket
DO NOT USE AN OPEN FLAME.
Manual Gas
Valve (on/off)
Burner Assembly
DO NOT USE AN OPEN FLAME.
Propane
Natural Gas
Содержание GPFGN
Страница 20: ...www napoleongrills com 20 EN 8 1 9 2 5 4 3 7 10 6 ...
Страница 41: ...www napoleongrills com 41 FR 8 1 9 2 5 4 3 7 10 6 ...
Страница 42: ...www napoleongrills com 42 FR NOTES ...
Страница 43: ...www napoleongrills com 43 FR NOTES ...
Страница 44: ...N415 0355 ...