WS-415-63 / 11.24.98

White / grey film
forms.

Sulphur from fuel is being de-
posited on glass, logs or com-
bustion chamber surfaces.

-  clean the glass with a recommended gas glass cleaner or a
non-abrasive ammonia or vinegar based glass cleaner. DO
NOT CLEAN GLASS WHEN HOT.
If deposits are not cleaned off regularly, the glass may be-
come permanently marked.

P

I

A

B

PILO

T

N

O

L

O

T

H I

LO

FF

O

Flames are consis-
tently too large or too
small. Carboning oc-
curs.

-  check pressure readings:
Inlet pressure can be checked by turning screw (A) counter-
clockwise 2 or 3 turns and then placing pressure gauge tubing
over the test point. Gauge should read 7" (minimum 4.5") wa-
ter column for natural gas or 13" (11" minimum) water column
for propane.
Outlet pressure can be checked the same as above using screw
(B). Gauge should read 3.5" water column for natural gas or
10" water column for propane.
AFTER TAKING PRESSURE READINGS, BE SURE TO TURN SCREWS
CLOCKWISE FIRMLY TO RESEAL. DO NOT OVERTORQUE.
Leak test with a soap and water solution.

Unit is over-fired or under-fired.

Main burner flame is
a blue, lazy, transpar-
ent flame.

Blockage in vent.

-  remove blockage. In really cold conditions, ice buildup may
occur on the terminal and should be removed as required.

-  refer to 

Figure 16

 to ensure correct location of storm

collars.

Incorrect installation.

Main burner goes out;
pilot goes out.

REFER TO "MAIN BURNER GOES OUT; PILOT STAYS ON"

Thermocouple shorting or
faulty.

-  check joint seals and installation.

Vent re-circulating

- loosen and tighten thermocouple
-  clean thermocouple and valve connection.
-  replace thermocouple.
-  replace valve.

PROBLEM

PROBLEM

PROBLEM

PROBLEM

PROBLEM

TEST SOLUTION

TEST SOLUTION

TEST SOLUTION

TEST SOLUTION

TEST SOLUTION

SYMPTOM

SYMPTOM

SYMPTOM

SYMPTOM

SYMPTOM

Carbon is being de-
posited on glass,
logs or combustion
chamber surfaces.

Flame is impinging on
the logs or combustion
chamber.

-  check that the logs are correctly positioned.
-  open air shutter to increase the primary air.
-  check the input rate: check the manifold pressure and orifice
size as specified by the rating plate values.
- check that the door gasketing is not broken or missing and
that the seal is tight.
- check that both 4" and 7" vent liners are free of holes and well
sealed at all joints.
- check that minimum rise per foor has been adhered to for any
horizontal venting.

Air shutter has become
blocked

-  ensure air shutter opening is free of lint or other obstructions.

Exhaust fumes
smelled in room,
headaches.

-  check all seals.
- check for chimney blockage
- check that chimney is installed to building code.
- room is in negative pressure; increase fresh air supply.

 Fireplace is spilling.

Содержание GDS 3700-P

Страница 1: ...722 6031 Email ask napoleon on ca Web www napoleon on ca Wolf Steel Ltd RR 1 9 Napoleon Rd Barrie ON Canada L4M 4Y8 705 721 1212 R 2000 Immediately call your gas supplier from a neighbour s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department W W W W WARNING ARNING ARNING ARNING ARNING If the information in these instructions is not followed e...

Страница 2: ...rtical Venting Installation Stove Vent Connection 10 10 10 10 10 GAS INST GAS INST GAS INST GAS INST GAS INSTALLA ALLA ALLA ALLA ALLATION TION TION TION TION 11 11 11 11 11 FINISHING FINISHING FINISHING FINISHING FINISHING Log Placement Charcoal Embers PG PG PG PG PG 12 12 12 12 12 OPERA OPERA OPERA OPERA OPERATION MAINTENANCE TION MAINTENANCE TION MAINTENANCE TION MAINTENANCE TION MAINTENANCE Ope...

Страница 3: ...pproval of an authorized company official Labour costs work however requires the prior approval of an authorized company official Labour costs to the account of to the account of to the account of to the account of to the account of NAPOLEON NAPOLEON NAPOLEON NAPOLEON NAPOLEON are based on a predetermined rate schedule and any repair are based on a predetermined rate schedule and any repair are ba...

Страница 4: ... or the ANSI NFPA 70 1990 NATIONAL ELECTRICAL CODE in the United States The blower power cord must be connected into a properly grounded receptacle The grounding prong must not be removed from the cord plug Provide adequate ventilation and combustion air Provide adequate accessibility clearance for servicing and operating the stove Never obstruct the front opening of the stove GENERAL INFORMA GENE...

Страница 5: ...nts burners and circulating blower and its passageway in the stove and venting system are kept clean The stove and its venting system should be inspected before use and at least annually by a qualified service person More frequent cleaning may be required due to exces sive lint from carpeting bedding material etc The stove area must be kept clear and free from combustible materials gasoline and ot...

Страница 6: ...SE IMMEDI AL RUN WITH A 57 INCH VERTICAL RISE IMMEDI AL RUN WITH A 57 INCH VERTICAL RISE IMMEDI AL RUN WITH A 57 INCH VERTICAL RISE IMMEDI AL RUN WITH A 57 INCH VERTICAL RISE IMMEDI A A A A ATEL TEL TEL TEL TELY ABOVE THE STOVE IS 20 FEET Y ABOVE THE STOVE IS 20 FEET Y ABOVE THE STOVE IS 20 FEET Y ABOVE THE STOVE IS 20 FEET Y ABOVE THE STOVE IS 20 FEET IF VERTICAL RISES GREA IF VERTICAL RISES GREA...

Страница 7: ...LA ALLA ALLA ALLATION EXAMPLE TION EXAMPLE TION EXAMPLE TION EXAMPLE TION EXAMPLE If a first run of 48 inches is required using the First Vent Run chart shows that a 51 inch vertical rise is necessary and a maximum second run of 32 inches is allowable IF NECESSAR IF NECESSAR IF NECESSAR IF NECESSAR IF NECESSARY Y Y Y Y THE FIRST RUN AND THE SECOND RUN MA THE FIRST RUN AND THE SECOND RUN MA THE FIR...

Страница 8: ... as illustrated in FIGURE 9 FIGURE9 G Seven feet above public walkways unless fitted with heat shield kit GD301 H One foot below windows that open I One foot from the side of doors and windows that open J One foot from permanently closed windows K One foot above grade L NOT above a regulator meter assembly or within three feet horizontally from the vertical centre line of the assembly M Six feet f...

Страница 9: ... 12 3 Slip the first section of 7 diameter stove pipe a minimum of 2 over the outer sleeve of the air terminal Secure to the sleeve using 3 screws Seal the joint and screw heads using high temperature sealant 4 Install the firestop wall plate to the finished interior wall maintain ing a 1 clearance to combustibles Insert the liners through the firestop Holding the air terminal lettering in an upri...

Страница 10: ...E INSTALLA ALLA ALLA ALLA ALLA TION IS COMPLETED AN OPTIONAL DECORA TION IS COMPLETED AN OPTIONAL DECORA TION IS COMPLETED AN OPTIONAL DECORA TION IS COMPLETED AN OPTIONAL DECORA TION IS COMPLETED AN OPTIONAL DECORATIVE BRASS BAND IS A TIVE BRASS BAND IS A TIVE BRASS BAND IS A TIVE BRASS BAND IS A TIVE BRASS BAND IS AV V V V VAILABLE FOR THIS AILABLE FOR THIS AILABLE FOR THIS AILABLE FOR THIS AILA...

Страница 11: ...cated on the rear wall of the combustion chamber The notch situated at the lower left of the back log should be centered evenly above the pilot assembly FIGURE 21 3 While supporting the back log to prevent it from falling forward set the three smaller logs into the pockets and grooves of the front and back logs respectively Log colours may vary During the initial use of the fireplace the colours w...

Страница 12: ...s supplier from a neighbour s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department FOR YOUR SAFETY READ BEFORE OPERATING A This fireplace is equipped with a pilot which must be lit by hand while following these instructions exactly B Before operating smell all around the fireplace area for gas and next to the floor because some gas is heavier ...

Страница 13: ...d will run for approximately 30 minutes after the stove has been turned off Use of the fan in creases the output of heat 1 Mount the variable speed switch insert the rheostat stem through the 3 8 diameter hole in the pedestal and from the front secure with the pal nut Add the knob 2 Remove the blower housing located at the rear of the stove Attach the bracket holding the heat sensor as shown to th...

Страница 14: ...ISCOPE TERMINAL KIT GD180 PERISCOPE TERMINAL KIT GD180 PERISCOPE TERMINAL KIT PART PART PART PART PART DESCRIPTION DESCRIPTION DESCRIPTION DESCRIPTION DESCRIPTION PART PART PART PART PART DESCRIPTION DESCRIPTION DESCRIPTION DESCRIPTION DESCRIPTION BM6790 90 ELBOW 7 DIAMETER GD201 PERISCOPE BM67ADJ 30 TO 53 ADJUSTABLE PIPE 7 DIAMETER GDS 500 77 FIRESTOP WALL PLATE GDS 020 32 HARDWARE BRTC7 BRASS TR...

Страница 15: ...15 WS 415 63 11 24 98 included with GD180 included with GD175 I H L O L F F N T I O O P O ...

Страница 16: ...cooled Allow approximately 60 seconds for the thermocouple to cool Pilot flame is not large enough turn up the pilot flame Pilot flame is not engulfing the thermocouple turn up pilot flame replace pilot assembly Thermocouple shorting loosen and tighten thermocouple clean thermocouple and valve connection replace thermocouple replace valve Faultly thermocouple replace Faulty valve replace System is...

Страница 17: ...emoved as required refer to Figure 16 to ensure correct location of storm collars Incorrect installation Main burner goes out pilot goes out REFER TO MAIN BURNER GOES OUT PILOT STAYS ON Thermocouple shorting or faulty check joint seals and installation Vent re circulating loosen and tighten thermocouple clean thermocouple and valve connection replace thermocouple replace valve PROBLEM PROBLEM PROB...

Страница 18: ...18 WS 415 63 11 24 98 NOTES ...

Отзывы: