![Napoleon GD27 - N Скачать руководство пользователя страница 17](http://html1.mh-extra.com/html/napoleon/gd27-n/gd27-n_installation-and-operation-instructions-manual_3287172017.webp)
17
WS-415-090 / 04.03.00
WHAT TO DO IF YOU SMELL GAS:
• Turn off all gas to the fireplace.
• Open windows.
• Do not try to light any appliance.
• Do not touch any electric switch; do not use any phone
in your building.
• Immediately call your gas supplier from a neighbour's
phone. Follow the gas supplier's instructions.
• If you cannot reach your gas supplier, call the fire de-
partment.
FOR YOUR SAFETY READ BEFORE LIGHTING:
A.
This fireplace is equipped with a pilot which must be lit
by hand while following these instructions exactly.
B.
Before operating smell all around the fireplace area for
gas and next to the floor because some gas is heavier
than air and will settle on the floor.
C.
Use only your hand to turn the gas control knob. Never
use tools. If the knob will not turn by hand, do not try to
repair it. Call a qualified service technician. Force or at-
tempted repair may result in a fire or explosion.
D.
Do not use this fireplace if any part has been under
water. Immediately call a qualified service technician to
inspect the fireplace and replace any part of the control
system and any gas control which has been under water.
5.
Turn gas knob counter-clockwise
to pilot.
6.
Depress slightly and hold gas knob while lighting the
pilot with the push button ignitor. Keep knob depressed for
one minute, then release. If pilot does not continue to burn,
repeat steps 3 through 5.
7.
With pilot lit, depress and turn gas knob counter-clock-
wise
to on.
8.
If equipped with remote on-off switch/thermostat, main
burner may not come on when you
turn valve to on. Remote switch
must be in the on position to ignite
burner.
9.
Turn on all electric power to the fireplace.
2.
Push in gas control knob slightly and turn clock-
wise
to off. Do not force.
TO TURN OFF GAS
1.
Turn off all electric power to the fireplace if service is to
be performed.
P
I
N
O
L
O
T
FF
O
GAS KNOB
FLAME
ADJUSTMENT
KNOB
O T
PIL
LO
IH
T
P
I
L
O
N
O
FF
O
PILOT
ON/OFF
KNOB
OPERATION / MAINTENANCE
weather season, the fireplace may emit a slight odour for a
few hours. This is caused by dust particles in the heat ex-
changer burning off. In both cases, open a window to suffi-
ciently ventilate the room.
Purge the gas line with the glass
door removed. Assure that a continuous gas flow is at
the burner before re-installing the door.
OPERATING INSTRUCTIONS
When lit for the first time, the fireplace will emit a slight
odour for a few hours. This is a normal temporary condi-
tion caused by the curing of the logs and the "burn-in" of
internal paints and lubricants used in the manufacturing
process and will not occur again. After extended periods of
non-operation such as following a vacation or a warm
LIGHTING INSTRUCTIONS
WARNING:
The gas valve has an interlock device which
will not allow the pilot burner to be lit until the thermo-
couple has cooled. Allow approximately 60 seconds for
the thermocouple to cool.
When lighting and re-lighting, the gas knob cannot be turned
from pilot to off unless the knob is
depressed slightly.
1.
Stop! Read the above safety information on this label.
2.
Turn off all electric power to the fireplace.
3.
Turn the gas knob clockwise
to off.
4.
Wait five (5) minutes to clear out any gas. If you smell
gas including near the floor. Stop! Follow "B" in the above
safety information on this label. If you don't smell gas go the
next step.
3.
Check to see that all burner ports are burning. Clean out
any of the ports which may not be burning or are not burning
properly.
4.
Check to see that the pilot flame is large enough to engulf
the thermocouple and thermopile and reaches toward the
burner with the third jet.
5.
Replace the cleaned logs.
6.
Check to see that the main burner ignites completely on
all openings when the gas knob for the burner is turned on.
A 5 to 10 second total light-up period is satisfactory. If ignition
takes longer, consult your Napoleon dealer / distributor.
7.
Check that the gasketing on the sides, top and bottom of
the door is not broken or missing. Replace if necessary.
MAINTENANCE
TURN OFF THE GAS AND ELECTRICAL POWER
BEFORE SERVICING THE FIREPLACE.
CAUTION: Label all wires prior to disconnection when ser-
vicing controls. Wiring errors can cause improper and dan-
gerous operation. Verify proper operation after servicing. This
fireplace and its venting system should be inspected be-
fore use and at least annually by a qualified service person.
The fireplace area must be kept clear and free of combus-
tible materials, gasoline or other flammable vapours and
liquids. The flow of combustion and ventilation air must not
be obstructed.
1.
In order to properly clean the burner and pilot assembly,
remove the logs to expose both assemblies.
2.
Keep the control compartment, logs, burner
,
air shutter
opening and the area surrounding the logs clean by vacu-
uming or brushing,
at least once a year
.