12
WS-415-090 / 04.03.00
FIGURES 26
FIGURES 25
FIGURE 24
FIGURE 23
To install the fireplace face flush with the finished wall,
position the framework to accomodate the thickness of the
finished wall. Pull out the four nailing tabs, attached on either
side of the fireplace and secure to the 2x4 framing to facilitate
drywall installation.
Combustible materials may be installed flush with the front
of the fireplace but must not cover any of the black face-
areas of the fireplace. Non-combustible material (brick,
stone or ceramic tile) may protrude in these areas.
It is not necessary to install a hearth extension with this
fireplace system.
Objects placed in front of the fireplace must be kept a
minimum of 48" from the front face of the unit.
Combustible mantle clearance can vary according to the
mantle depth.
FIGURES 26.
Use the graph to help evaluate
the clearance needed.
MOBILE HOME INSTALLATION
In Canada, mobile home installation may be vented hori-
zontally or vertically. In the United States, it may only be
installed vertically. See "Vertical Venting" for installation.
The fireplace is equipped with two 1/4" diameter holes
located in the front left and right corners of the base. For
mobile home installations, the fireplace must be fastened
in place. Use screws, inserted through the holes in the
base to secure. It is recommended that the fireplace be
secured in all installations.
Always turn off the pilot and the fuel supply at the
source, prior to moving the mobile home.
After moving the mobile home and prior to lighting the
fireplace, ensure that the logs are positioned correctly.
FRAMING
It is best to frame your fireplace after it is positioned and
the vent system is installed. Use 2x4's and frame to local
building codes.
FIGURE 23-25.