background image

32

W415-0763 / B / 10.28.11

9.0 REPLACEMENTS

Contact your dealer or the factory for questions concerning prices and policies on replacement parts. Normally 
all parts can be ordered through your Authorized dealer / distributor. 

FOR WARRANTY REPLACEMENT PARTS, A PHOTOCOPY OF THE ORIGINAL INVOICE WILL BE 
REQUIRED TO HONOUR THE CLAIM.

When ordering replacement parts always give the following information:
• 

Model & Serial Number of appliance

• 

Installation date of appliance

• Part 

number

• 

Description of part

• Finish

* IDENTIFIES ITEMS WHICH ARE NOT ILLUSTRATED. FOR 
FURTHER INFORMATION, CONTACT YOUR AUTHORIZED DEALER.

41.1

FAILURE TO POSITION THE PARTS 

IN ACCORDANCE WITH THIS 

MANUAL OR FAILURE TO USE ONLY 

PARTS SPECIFICALLY APPROVED 

WITH THIS APPLIANCE MAY 

RESULT IN PROPERTY DAMAGE OR 

PERSONAL INJURY.

!

WARNING

 COMPONENTS

REF #

1100

1150

1400

1450

1900

DESCRIPTION

A

W090-0001

W090-0001

W090-0001

W090-0001

W090-0001

BRICK

B

W090-0002

W090-0002

W090-0002

W090-0002

W090-0002

BRICK

C

W090-0003

W090-0003

N/A

N/A

W090-0003

BRICK

D

W090-0004

W090-0004

W090-0004

W090-0004

W090-0004

BRICK, LEFT

D

W090-0005

W090-0005

W090-0005

W090-0005

W090-0005

BRICK, RIGHT

E

W090-0018

W090-0018

W090-0018

W090-0018

W090-0018

BRICK

F

W090-0019

W090-0019

W090-0019

W090-0019

W090-0019

BRICK

G

W090.0016

W090.0016

W090.0016

N/A

W090.0016

BRICK

H

W090-0017

W090-0017

W090-0017

N/A

W090-0017

BRICK

I

W018-0077

W018-0077

N/A

N/A

N/A

BAFFLE, FIBRE

J

N/A

N/A

W018-0078

W018-0078

W018-0130

BAFFLE, FIBRE

12

W135-0238

W135-0238

W135-0238

N/A

W135-0238

CAST ASH LIP

13

W010-0347

W010-0347

W010-0347

W010-0347

W010-0347

AIRWASH GASKET & SHIELD

14*

W570-0007

W570-0007

W570-0007

W570-0007

W570-0007

SCREWS FOR MANIFOLD SHIELD

15

GZ552

GZ552

GZ552

GZ552

GZ552

REPLACEMENT FAN

16

W325-0045

W325-0033

W325-0045

W325-0045

W325-0045

SPRING HANDLE LARGE

17

W325-0044

W325-0032

W325-0044

W325-0044

W325-0044

SPRING HANDLE SMALL

18*

W018-0077 (#10)

W018-0077 (#10)

W018-0078 (#11)

W018-0078 (#11)

W018-0092 (#12) 
W018-0093 (#13)

FIBRE BAFFLE

19*

EP-11MS

N/A

EP-14MS

EP-14MS

EP-19MS

MANIFOLD SHIELD

20

KB-35

N/A

KB-35

KB-35

KB-35

VARIABLE SPEED CONTROL C/W KNOB

21*

W580-0001

W580-0001

W580-0002

W580-0005

W580-0003

COMPLETE BRICK SET

22*

CL28

N/A

CL28

N/A

CL28

BLACK CANOPY LOUVRES

23*

CL28G

N/A

CL28G

N/A

CL28G

GOLD PLATED CANOPY LOUVRES

24

W010-0349

W715-0641

W010-0349

N/A

W010-0349

PEDESTAL TRIM

25

W010-0243

N/A

W010-0243

N/A

W010-0243

ASH PAN (NO FRONT PLATE)

26

W325-0011

N/A

W325-0011

N/A

W325-0011

ASH PAN HANDLE

27

W200-0077

N/A

GS-330K

N/A

GS-330K

BLACK TRIVET

28

N/A

W710-0030

N/A

W710-0025

N/A

ASH TRAY

29

N/A

W325-0041

N/A

N/A

N/A

ASH DRAWER HANDLE

30

N/A

W525-0024

N/A

N/A

N/A

POT FENDER

31*

N/A

W290-0101

N/A

N/A

N/A

LID GASKET

32

N/A

W135-0234**

N/A

N/A

N/A

CAST - FIREBOX TOP

33

N/A

W135-0235**

N/A

N/A

N/A

CAST - LID

34

N/A

W135-0236**

N/A

N/A

N/A

CAST - FLUE COLLAR

35

N/A

W135-0237**

N/A

N/A

N/A

CAST - PEDESTAL BASE

36

N/A

W135-0238**

N/A

N/A

N/A

CAST - ASH TRAY

37*

N/A

W325-0040

N/A

N/A

N/A

HANDLE - LID LIFTER

Содержание EPA 1400

Страница 1: ...ding or fire authority and follow their guidelines Operate only with the door tightly closed Burn wood behind the log retainer directly on the firebricks Do not use an elevated grate or otherwise rais...

Страница 2: ...8 5 0 FINISHING 19 5 1 DOOR REMOVAL INSTALLATION 19 5 2 DOOR AND HANDLE INSTALLATION 19 5 3 ORNAMENTAL TRIVET INSTALLATION 20 5 4 PEDESTAL TRIM INSTALLATION IF SUPPLIED 20 5 5 BRICKS AND BAFFLE INSTAL...

Страница 3: ...KIT INSTALLATION section Handle see DOOR AND HANDLE INSTALLATION section Draft see AIR CONTROL section Door see DOOR REMOVAL INSTALLATION section Rating plate see RATING PLATE INFORMATION section 145...

Страница 4: ...y screen or guard removed for servicing must be replaced prior to operating the appliance Under no circumstances should this appliance be modified This appliance must not be connected to a chimney flu...

Страница 5: ...7ft3 1 7ft3 2 25ft3 3 0ft3 APPROX AREA HEATED 600 1500 ft2 600 1500 ft2 1000 2000 ft2 1000 3500 ft2 HEAT OUTPUT HIGH BURN 55 000 BTU 55 000 BTU 70 000 BTU 85 000 BTU DURATION LOW FIRE 7 Hours 7 Hours...

Страница 6: ...THOROUGHLY BEFORE STARTING YOUR INSTALLATION AND FOLLOW THEM CAREFULLY THROUGHOUT YOUR PROJECT WARNING Before beginning your installation consult with your local building code agency or fire officials...

Страница 7: ...er of fibre baffles at the top to maintain a high tem perature in the combustion chamber so that gases mixing with the preheated air from the secondary air manifold tube are easily ignited and burned...

Страница 8: ...TEMENT SUR L TRE AVERTISSEMENT RISQUE D CHAPPEMENT DE FUM E TENIR LA PORTE FERM E LORSQUE LE PO LE FONCTIONNE REMPLACEZ LA VITRE PAR UNE VITRE EN C RAMIQUE SEULEMENT NE SURCHAUFFEZ PAS L APPAREIL SI L...

Страница 9: ...CE BOTTOM EXCLUDING HEARTH HEIGHT WARNING BACK WALL B SIDE WALL A BACK WALL C SIDE WALL F D E E PARALLEL CORNER SINGLE WALL CONNECTOR DOUBLE WALL CONNECTOR 1100 1150 1400 1450 1900 1100 1400 1450 1900...

Страница 10: ...in the house Other devices are present that exhaust house air The house has tight fitting windows and or is equipped with a well sealed vapour barrier WARNING IF ROOM AIR STARVATION OCCURS BECAUSE THE...

Страница 11: ...knockout in the pedestal back or through a hole in the floor to line up with the hole in the pedestal base Use a fresh air kit Secure the 4 inch diameter aluminum liner by flaring the end once it is...

Страница 12: ...E THE POSSIBILITY OF APPLIANCE SMOKING OR AIR FLOW REVERSAL THE OUTSIDE AIR INLET MUST REMAIN CLEAR OF LEAVES DEBRIS ICE AND OR SNOW IT MUST BE UNRE STRICTED WHILE APPLIANCE IS IN USE TO PREVENT ROOM...

Страница 13: ...URE STRUCTURAL INTEGRITY IS NOT COMPROMISED FIRESTOP SPACERS MUST BE USED WHENEVER THE CHIMNEY PENETRATES A CEILING FLOOR AREA THE TOTAL HORIZONTAL VENT LENGTH SHOULD NOT EXCEED 40 OF THE CHIMNEY HEIG...

Страница 14: ...tical installation the total length of the connector can be longer and connected without problem to the chimney at the ceiling level There should never be more than two 90 elbows in the entire connect...

Страница 15: ...ney must extend at least 3 feet above its point of contact with the roof and at least 2 feet higher than any wall roof building or obstacle within 10 feet horizontally 59 1A 3 FT MIN 3 FT MIN 3 FT MIN...

Страница 16: ...hat the chimney passes through If your chimney system is enclosed within the attic area a rafter radiation shield is required C Hold a plumb bob from the underside of the roof to determine where the o...

Страница 17: ...or any specific requirements Consult with your dealer regarding special connection components available for use for wall pass throughs Use only parts that have been tested and listed for use in a wall...

Страница 18: ...you are using a masonry chimney it is important that it be built in compliance with the specifications of the Building Code in your region It must normally be lined with fire clay bricks metal or clay...

Страница 19: ...install the door PINS 5 1 DOOR REMOVAL INSTALLATION 5 2 DOOR AND HANDLE INSTALLATION DOOR HANDLE NUT DOOR HANDLE LATCH LOCK WASHER DOOR SPACER SPRING WASHER FRONT VIEW NOTE Position of door handle lat...

Страница 20: ...into place for your appliance as illustrated A Install the bottom bricks working from the back of the appliance forward B Before installing the back bricks loosen the screw holding the brick retainer...

Страница 21: ...J A A A A A A A A A A A A A A A A A A A A A B B B B G H E F A A C C B B D D Brick Retainers 9 x 2 x 19 5 8 Fibre Baffles W018 0130 X2 J A 1 1 4 x 4 1 2 x 9 F 1 1 4 x 2 1 2 x 6 1 8 B 1 1 4 x 3 x 9 G 1...

Страница 22: ...illustrated from the preferred side of the stove rear Secure the lid lifter hook as illustrated facing out to the side or bend it towards the back LID LIFTER HOOK LID LIFTER HANDLE FIREBOX CAST TOP O...

Страница 23: ...f the appliance B Install the blower and housing as shown using the 4 screws supplied C Loosen the thermal switch bracket 2 screws and slide the bracket forward until the thermodisc is touching the re...

Страница 24: ...will reduce the firebox temperature and result in an unsatisfactory burn Remember it is more efficient to burn medium sized wood briskly and refuel frequently than to load the appliance with large log...

Страница 25: ...optimum temperature Reopen the door and or draft control to re establish a brisk fire The other problem may have been wet wood The typical symptom is sizzling wood and moisture being driven from the...

Страница 26: ...with the ash dump door blocked open or a poor gasket seal on the main door 93 1 A flash fire is a small fire burned quickly when you don t need much heat After your kindling has caught load at least...

Страница 27: ...ash pan when transporting the ashes to a closed container with a tight fitting lid for storage Carry the ash pan using the front and back handles REAR FOLDING HANDLE TO OPEN PULL AND ROTATE ASH WELL C...

Страница 28: ...orrect fuel or small fuel pieces which would normally be used as kindling Leaving the door ajar too long and creating extreme temperatures as the air rushes in the open door Burning your appliance wit...

Страница 29: ...e chimney is cold NOTE Appliances burned consistently without hot fires may result in significant creosote accumulations in the chimney Certain items and considerations are important in chimney cleani...

Страница 30: ...prints or other marks from the plated surfaces before operating the appliance for the first time Use a glass cleaner or vinegar and towel to clean If not cleaned properly before operating for the firs...

Страница 31: ...has cracks in the end grain Cut the wood so that it will fit horizontally front to back making for easier loading and less of a likelihood that the wood will roll onto the glass Manufactured firelogs...

Страница 32: ...77 W018 0077 N A N A N A BAFFLE FIBRE J N A N A W018 0078 W018 0078 W018 0130 BAFFLE FIBRE 12 W135 0238 W135 0238 W135 0238 N A W135 0238 CAST ASH LIP 13 W010 0347 W010 0347 W010 0347 W010 0347 W010 0...

Страница 33: ...W N A H222 GW DOOR GOLD EARLY AMERICAN 39 H222 SSW H222 SSW H222 SSW N A H222 SSW DOOR BRUSHED STAINLESS STEEL EARLY AMERICAN 40 W010 1071 W010 1071 W010 1071 W010 1071 W010 1071 DOOR GLASS WITH GASKE...

Страница 34: ...34 W415 0763 B 10 28 11 27 20 45 30 32 33 34 40 38 16 25 39 35 29 28 13 12 15 24 26 17 36...

Страница 35: ...kage Inspect chimney Smokes when door is open Cold air blockage Burn a piece of paper to establish a draft Insufficient draft Add more pipe Let air stabilize before opening door Ensure baffles are pos...

Страница 36: ...sibility of NAPOLEON NAPOLEON reserves the right to have its representative inspect any product or part thereof prior to honouring any warranty claim All parts replaced under the President s Limited L...

Страница 37: ...37 W415 0763 B 10 28 11 43 1 12 0 SERVICE HISTORY...

Страница 38: ...38 W415 0763 B 10 28 11 13 0 NOTES 44 1...

Страница 39: ...39 W415 0763 B 10 28 11 44 1...

Страница 40: ...40 W415 0763 B 10 28 11 44 1...