background image

8

W415-0763 / B / 10.28.11

2.5  RATING PLATE INFORMATION

For rating plate location, see 
“INSTALLATION OVERVIEW” 
section.

This illustration is for reference 
only. Refer to the rating plate 
on the appliance for accurate 
information.

1400 SERIES RATING PLATE ILLUSTRATED

SAMPLE

LISTED SOLID FUEL BURNING FIREPLACE INSERT / 
ENCASTRÉ  À COMBUSTIBLE SOLIDE HOMOLOGUÉ

TESTED TO / TESTÉ SELON :

ULC S628 / UL 1482

FROM HEATER / DU POÊLE

RESIDENTIAL / RÉSIDENTIEL

1400

12IN/PO (305 mm) 
12IN/PO (305 mm) 

6IN/PO (150 mm) 

USING DOUBLE WALL CONNECTOR / UTILISATION

D’UN CONDUIT DE RACCORDEMENT À

DOUBLE PAROI

MAISON / MOBILE HOME*

1400

1400

10IN/PO (254 mm)

10IN/PO (254 mm)

6IN/PO (152 mm)

6IN/PO (152 mm)

4IN/PO (102 mm)

4IN/PO (102 mm)

EPI 1402

INSTALL AND USE ONLY IN 
ACCORDANCE WITH THE 
MANUFACTURER’S 
INSTRUCTIONS AND LOCAL 
BUILDING CODES. 
MINIMUM CEILING HEIGHT: 
7FT (2.13m)

HEARTH EXTENSION / 
COMBUSTIBLE FLOOR 
PROTECTION:

 IF INSTALLED 

ON A COMBUSTIBLE FLOOR, 
UNIT MUST BE PLACED ON A 
NON-COMBUSTIBLE FLOOR 
PROTECTOR EXTENDING 18” 
(455mm) IN FRONT AND 8” 
(205mm) TO THE SIDES AND 
BACK. 

CHIMNEY TYPE:

 MINIMUM 6” 

(152mm) DIAMETER 
APPROVED RESIDENTIAL 
TYPE FOR MOBILE HOME USE 
A CHIMNEY LISTED TO ULC 
S629 IN CANADA OR UL 103HT 
IN THE USA.

CHIMNEY CONNECTOR:

 6” 

(152mm) DIAMETER MINIMUM 
24 GAUGE STEEL MINIMUM 
CLEARANCE FROM 
HORIZONTAL CONNECTOR 
AND CEILING 18” (455mm).
DO NOT OBSTRUCT SPACE 
UNDER HEATER.
SPECIAL METHODS ARE 
REQUIRED WHEN PASSING A 
CHIMNEY THROUGH A WALL 
OR CEILING. SEE INSTRUC-
TIONS AND BUILDING CODES.
DO NOT CONNECT THIS UNIT 
TO A CHIMNEY FLUE SERVING 
ANOTHER APPLIANCE.

FUEL:

 FOR USE WITH WOOD 

ONLY. DO NOT USE GRATE OR 
ELEVATE FIRE. BUILD WOOD 
FIRE DIRECTLY ON HEARTH.

WARNING:

 RISK OF SMOKE 

SPILLAGE. OPERATE ONLY 
WITH DOOR FULLY CLOSED.
REPLACE GLASS ONLY WITH 
CERAMIC GLASS.
DO NOT OVERFIRE. IF 
HEATER OR CHIMNEY 
CONNECTORS GLOW, YOU 
ARE OVERFIRING. INSPECT 
AND CLEAN CHIMNEY 
FREQUENTLY. UNDER 
CERTAIN CONDITIONS OF 
USE CREOSOTE BUILD-UP 
MAY OCCUR RAPIDLY.

OPTIONAL BLOWER KIT:

 

EP-62, 115V, 60HZ, 0.82AMP. 
ROUTE CORD AWAY FROM 
UNIT.

DANGER:

 RISK OF 

ELECTRICAL SHOCK. 
DISCONNECT POWER 
BEFORE SERVICING UNIT.

INSERT:

 INSTALL AND USE 

ONLY IN SOLID FUEL 
BURNING FIREPLACES. DO 
NOT REMOVE BRICKS OR 
MORTAR FROM SOLID FUEL 
BURNING FIREPLACE. 
INSTALL WITH A POSITIVE 
FLUE CONNECTOR AND 
FACEPLATE.

POUR INSTALLATION ET 
UTILISATION CONFORM

ÉMENT AUX 

INSTRUCTIONS DU FABRICANT ET 
AUX CODES LOCAUX DU BÂTIMENT.
HAUTEUR DE PLAFOND MINIMAL 
7PI (2,13m).

PROLONGEMENT 
D’ÂTRE/PROTECTION DU 
PLANCHER COMBUSTIBLE: 

SI 

INSTALLÉ SUR UN PLANCHER 
COMBUSTIBLE, L’APPAREIL DOIT 
ÊTRE PLACÉ SUR UNE PLAQUE 
PROTECTRICE INCOMBUSTIBLE 
S’ÉTENDANT SUR 18” (455mm) 

À 

L’AVANT ET 8” (205mm) À L’ARRIÈRE 
ET SUR LES CÔTÉS.

TYPE DE CHIMNÉE:

 DIAMÈTRE 

MINIMAL DE 6” (152mm) 
APPROUVÉE POUR USAGE 
RÉSIDENTIEL. MAISON MOBILE 
EMPLOYEZ UNE CHEMINÉE 
HOMOLOGUÉE ULC S629 AU 
CANADA OU UL 103HT AUX 
ÉTATS-UNIS.

RACCORD DE CHEMINÉE: 

DIAMÈTRE DE 6” (152mm) D’ACIER 
DE CALIBRE 24 MINIMUM. 18” 
(455mm) DE DÉGAGEMENT MINIMAL 
ENTRE LE RACCORD HORIZONTAL 
ET LE PLAFOND. 
NE RIEN ENTREPOSER SOUS 
L’APPAREIL.
DES MÉTHODES SPÉCIALES SONT 
REQUISES LORSQU’UNE CHEMINÉE 
TRAVERSE UN MUR OU UN 
PLAFOND. VOIR LES INSTRUC-
TIONS ET LES CODES DU 
BÂTIMENT. 
NE PAS RACCORDER À LA 
CHEMINÉE D’UN AUTRE APPAREIL.

COMBUSTIBLE:

 POUR USAGE AVEC 

LE BOIS SEULEMENT. N’UTILISEZ 
PAS DE CHENET OU NE 
SURÉLEVEZ PAS LE BOIS. 
PRÉPAREZ LE FEU DIRECTEMENT 
SUR L’ÂTRE.

AVERTISSEMENT: 

RISQUE 

D’ÉCHAPPEMENT DE FUMÉE. TENIR 
LA PORTE FERMÉE LORSQUE LE 
POÊLE FONCTIONNE. REMPLACEZ 
LA VITRE PAR UNE VITRE EN 
CÉRAMIQUE SEULEMENT. 
NE SURCHAUFFEZ PAS L’APPAREIL. 
SI L’APPAREIL OU LES RACCORDS 
ROUGEOIENT, L’APPAREIL 
SURCHAUFEE. INSPECTEZ ET 
NETTOYEZ LA CHEMINÉE 
FRÉQUEMMENT. DANS CERTAINES 
CONDITIONS, DES DÉPÔTS DE 
CRÉOSOTE PEUVENT SE FORMER 
RAPIDEMENT.

SOUFFLERIE OPTIONNELLE: 

EP-62, 

115V, 60HZ, 0,82A. TENEZ LE 
CORDON ÉLECTRIQUE LOIN DE 
L’APPAREIL. 

DANGER:

 RISQUE DE SECOUSSE 

ÉLECTRIQUE. DÉBRANCHEZ AVANT 
DE PROCÉDER À L’ENTRETIEN.

ENCASTRÉ: 

INSTALLEZ ET UTILISEZ 

SEULEMENT DANS UN FOYER À 
COMBUSTIBLE SOLIDE. NE RETIREZ 
PAS DE MORTIER, NI BRIQUES DU 
FOYER À COMBUSTIBLE SOLIDE.
INSTALLEZ AVEC UNE GAINE 
CONFORME ET UNE PLAQUE DE 
RECOUVREMENT.

CONTACT LOCAL BUILDING FIRE OFFICIALS ABOUT RESTRICTIONS AND 
INSTALLATION INSPECTION IN YOUR AREA. MODEL 1400 IS SUITABLE FOR USE 
IN MOBILE HOMES WHEN USED WITH OUTSIDE AIR INSTALLATION KIT (111KT). A 
MINIMUM CLEARANCE OF 18” (457mm) TO THE CHIMNEY CONNECTOR MAY BE 
REQUIRED BY THE AUTHORITY HAVING JURISDICTION.
RENSEIGNEZ-VOUS AUPR

ÈS DES AUTORITÉS LOCALES DU BÂTIMENT ET DU 

SERVICE DES INCENDIES AU SUJET DES RESTRICTIONS ET DES INSPECTIONS 
D’INSTALLATION DANS VOTRE RÉGION. LES MODÈLES 1400 PEUVENT ÊTRE 
INSTALLÉS DANS UNE MAISON MOBILE SI INSTALLÉS CONJOINTEMENT AVEC UNE 
PRISE D’AIR EXTÉRIEUR (111KT). UN DÉGAGEMENT MINIMAL DE 18” (457mm) 
JUSQU’AU RACCORD DE LA CHEMINÉE PEUT ÊTRE EXIGÉ PAR L’AUTORITÉ AYANT 
JURIDICTION.

8"

8"

18"

8"

ALCOVE

A"

B"

C

BACK WALL (M/A)

45°

SIDE W

A

LL

 (M/L)

BACK WALL (M/A)

SIDE W

A

LL

 (M/L)

B

A

IF THE STOVE IS TO BE INSTALLED ON A COMBUSTIBLE FLOOR, IT MUST BE 
PLACED ON AN APPROVED NON-COMBUSTIBLE HEARTH PAD, THAT 
EXTENDS 8” (200mm) BEYOND THE STOVE SIDES AND BACK, AND 18” 
(455mm) TO THE FRONT.
SI LE PO

ÊLE EST INSTALLÉ SUR UN PLANCHER COMBUSTIBLE, IL DOIT ÊTRE PLACÉ 

SUR UNE BASE DE PROTECTION INCOMBUSTIBLE CERTIFÉE QUI DOIT DÉPASSER 
LES CÔTÉS ET L’AMÉRE DU POÊLE DE 8” (200mm) ET SE PROLONGER DE 18” 
(455mm) SUR LE DEVANT.
MINIMUM CLEARANCE TO COMBUSTIBLE MATERIAL WITH SINGLE WALL 
CHIMNEY CONNECTOR / D

ÉGAGEMENTS MINIMAUX AUX MATÉRIAUX 

COMBUSTIBLES AVEC RACCORD DE CHEMINÉE À PAROI SIMPLE:

*

MODEL 1400 MAY BE INSTALLED INTO A MOBILE HOME IN THE UNITED 

STATES ONLY. 

*

LE MODÈLE 1400 NE PEUT ÊTRE INSTALLÉ QUE DANS UNE MAISON 

MOBILE AUX ÉTATS-UNIS SEULEMENT.

CEILING / PLAFOND

C

D

B

A

FLOOR / PLANCHER

HOT WHILE IN OPERATION.  DO NOT TOUCH.  KEEP CHILDREN,
CLOTHING AND FURNITURE AWAY. CONTACT MAY CAUSE
SKIN BURNS.

QUAND L’APPAREIL FONCTIONNE, LA SURFACE DEVIENT
CHAUDE. NE PAS TOUCHER. TENIR LES ENFANTS, LES
VÊTEMENTS ET LES MEUBLES À L’ÉCART. LE CONTACT PEUT
CAUSER DES BRÛLURES À LA PEAU.

CAUTION:

ATTENTION:

W385-0401 / J

DATE CODE / DE DATE

EPA1400

CLEARANCES TO COMBUSTIBLE CONSTRUCTION / 
D

ÉGAGEMENTS AUX MATÉRIAUX COMBUSTIBLES: 

(MEASURED TO UNIT / À PARTIR DE L’APPAREIL)

A  SIDE FACING / CÔTÉ   

1 IN/PO (25mm)

*

B  TOP FACING / DESSUS 

28 IN/PO (710mm)

C  MANTEL / TABLETTE   

28 IN/PO (710mm)

D  SIDE WALL / MUR LATÉRAL 

17 IN/PO (430mm)

*

CLEARANCE TO EDGE OF FLASHING / DÉGAGEMENT AU 

BORD DE LA FAÇADE

1400

1400L

1402

1450

WOLF STEEL LTD.

24 NAPOLEON ROAD, BARRIE, ON, L4M 0G8 CANADA

1400C

9700539 (WSL)

4001657 (NGZ)

4001658 (NAC)

4001659 (WUSA)

LISTED SOLID FUEL BURNING SPACE HEATER / 

POÊLE À COMBUSTIBLE SOLIDE HOMOLOGUÉ

TESTED TO: / TESTÉ SELON : UL1482 / ULC S627

MODEL / MODÈLE - EPA 1400

15982

U.S. Environmental Protection Agency 

Certified to comply with July 1990, particulate emissions standards/

Certifié conforme à la norme d’ émanation de particles de juillet 1990: 40 CFR Part 60, Subpart AAA

Содержание EPA 1400

Страница 1: ...ding or fire authority and follow their guidelines Operate only with the door tightly closed Burn wood behind the log retainer directly on the firebricks Do not use an elevated grate or otherwise rais...

Страница 2: ...8 5 0 FINISHING 19 5 1 DOOR REMOVAL INSTALLATION 19 5 2 DOOR AND HANDLE INSTALLATION 19 5 3 ORNAMENTAL TRIVET INSTALLATION 20 5 4 PEDESTAL TRIM INSTALLATION IF SUPPLIED 20 5 5 BRICKS AND BAFFLE INSTAL...

Страница 3: ...KIT INSTALLATION section Handle see DOOR AND HANDLE INSTALLATION section Draft see AIR CONTROL section Door see DOOR REMOVAL INSTALLATION section Rating plate see RATING PLATE INFORMATION section 145...

Страница 4: ...y screen or guard removed for servicing must be replaced prior to operating the appliance Under no circumstances should this appliance be modified This appliance must not be connected to a chimney flu...

Страница 5: ...7ft3 1 7ft3 2 25ft3 3 0ft3 APPROX AREA HEATED 600 1500 ft2 600 1500 ft2 1000 2000 ft2 1000 3500 ft2 HEAT OUTPUT HIGH BURN 55 000 BTU 55 000 BTU 70 000 BTU 85 000 BTU DURATION LOW FIRE 7 Hours 7 Hours...

Страница 6: ...THOROUGHLY BEFORE STARTING YOUR INSTALLATION AND FOLLOW THEM CAREFULLY THROUGHOUT YOUR PROJECT WARNING Before beginning your installation consult with your local building code agency or fire officials...

Страница 7: ...er of fibre baffles at the top to maintain a high tem perature in the combustion chamber so that gases mixing with the preheated air from the secondary air manifold tube are easily ignited and burned...

Страница 8: ...TEMENT SUR L TRE AVERTISSEMENT RISQUE D CHAPPEMENT DE FUM E TENIR LA PORTE FERM E LORSQUE LE PO LE FONCTIONNE REMPLACEZ LA VITRE PAR UNE VITRE EN C RAMIQUE SEULEMENT NE SURCHAUFFEZ PAS L APPAREIL SI L...

Страница 9: ...CE BOTTOM EXCLUDING HEARTH HEIGHT WARNING BACK WALL B SIDE WALL A BACK WALL C SIDE WALL F D E E PARALLEL CORNER SINGLE WALL CONNECTOR DOUBLE WALL CONNECTOR 1100 1150 1400 1450 1900 1100 1400 1450 1900...

Страница 10: ...in the house Other devices are present that exhaust house air The house has tight fitting windows and or is equipped with a well sealed vapour barrier WARNING IF ROOM AIR STARVATION OCCURS BECAUSE THE...

Страница 11: ...knockout in the pedestal back or through a hole in the floor to line up with the hole in the pedestal base Use a fresh air kit Secure the 4 inch diameter aluminum liner by flaring the end once it is...

Страница 12: ...E THE POSSIBILITY OF APPLIANCE SMOKING OR AIR FLOW REVERSAL THE OUTSIDE AIR INLET MUST REMAIN CLEAR OF LEAVES DEBRIS ICE AND OR SNOW IT MUST BE UNRE STRICTED WHILE APPLIANCE IS IN USE TO PREVENT ROOM...

Страница 13: ...URE STRUCTURAL INTEGRITY IS NOT COMPROMISED FIRESTOP SPACERS MUST BE USED WHENEVER THE CHIMNEY PENETRATES A CEILING FLOOR AREA THE TOTAL HORIZONTAL VENT LENGTH SHOULD NOT EXCEED 40 OF THE CHIMNEY HEIG...

Страница 14: ...tical installation the total length of the connector can be longer and connected without problem to the chimney at the ceiling level There should never be more than two 90 elbows in the entire connect...

Страница 15: ...ney must extend at least 3 feet above its point of contact with the roof and at least 2 feet higher than any wall roof building or obstacle within 10 feet horizontally 59 1A 3 FT MIN 3 FT MIN 3 FT MIN...

Страница 16: ...hat the chimney passes through If your chimney system is enclosed within the attic area a rafter radiation shield is required C Hold a plumb bob from the underside of the roof to determine where the o...

Страница 17: ...or any specific requirements Consult with your dealer regarding special connection components available for use for wall pass throughs Use only parts that have been tested and listed for use in a wall...

Страница 18: ...you are using a masonry chimney it is important that it be built in compliance with the specifications of the Building Code in your region It must normally be lined with fire clay bricks metal or clay...

Страница 19: ...install the door PINS 5 1 DOOR REMOVAL INSTALLATION 5 2 DOOR AND HANDLE INSTALLATION DOOR HANDLE NUT DOOR HANDLE LATCH LOCK WASHER DOOR SPACER SPRING WASHER FRONT VIEW NOTE Position of door handle lat...

Страница 20: ...into place for your appliance as illustrated A Install the bottom bricks working from the back of the appliance forward B Before installing the back bricks loosen the screw holding the brick retainer...

Страница 21: ...J A A A A A A A A A A A A A A A A A A A A A B B B B G H E F A A C C B B D D Brick Retainers 9 x 2 x 19 5 8 Fibre Baffles W018 0130 X2 J A 1 1 4 x 4 1 2 x 9 F 1 1 4 x 2 1 2 x 6 1 8 B 1 1 4 x 3 x 9 G 1...

Страница 22: ...illustrated from the preferred side of the stove rear Secure the lid lifter hook as illustrated facing out to the side or bend it towards the back LID LIFTER HOOK LID LIFTER HANDLE FIREBOX CAST TOP O...

Страница 23: ...f the appliance B Install the blower and housing as shown using the 4 screws supplied C Loosen the thermal switch bracket 2 screws and slide the bracket forward until the thermodisc is touching the re...

Страница 24: ...will reduce the firebox temperature and result in an unsatisfactory burn Remember it is more efficient to burn medium sized wood briskly and refuel frequently than to load the appliance with large log...

Страница 25: ...optimum temperature Reopen the door and or draft control to re establish a brisk fire The other problem may have been wet wood The typical symptom is sizzling wood and moisture being driven from the...

Страница 26: ...with the ash dump door blocked open or a poor gasket seal on the main door 93 1 A flash fire is a small fire burned quickly when you don t need much heat After your kindling has caught load at least...

Страница 27: ...ash pan when transporting the ashes to a closed container with a tight fitting lid for storage Carry the ash pan using the front and back handles REAR FOLDING HANDLE TO OPEN PULL AND ROTATE ASH WELL C...

Страница 28: ...orrect fuel or small fuel pieces which would normally be used as kindling Leaving the door ajar too long and creating extreme temperatures as the air rushes in the open door Burning your appliance wit...

Страница 29: ...e chimney is cold NOTE Appliances burned consistently without hot fires may result in significant creosote accumulations in the chimney Certain items and considerations are important in chimney cleani...

Страница 30: ...prints or other marks from the plated surfaces before operating the appliance for the first time Use a glass cleaner or vinegar and towel to clean If not cleaned properly before operating for the firs...

Страница 31: ...has cracks in the end grain Cut the wood so that it will fit horizontally front to back making for easier loading and less of a likelihood that the wood will roll onto the glass Manufactured firelogs...

Страница 32: ...77 W018 0077 N A N A N A BAFFLE FIBRE J N A N A W018 0078 W018 0078 W018 0130 BAFFLE FIBRE 12 W135 0238 W135 0238 W135 0238 N A W135 0238 CAST ASH LIP 13 W010 0347 W010 0347 W010 0347 W010 0347 W010 0...

Страница 33: ...W N A H222 GW DOOR GOLD EARLY AMERICAN 39 H222 SSW H222 SSW H222 SSW N A H222 SSW DOOR BRUSHED STAINLESS STEEL EARLY AMERICAN 40 W010 1071 W010 1071 W010 1071 W010 1071 W010 1071 DOOR GLASS WITH GASKE...

Страница 34: ...34 W415 0763 B 10 28 11 27 20 45 30 32 33 34 40 38 16 25 39 35 29 28 13 12 15 24 26 17 36...

Страница 35: ...kage Inspect chimney Smokes when door is open Cold air blockage Burn a piece of paper to establish a draft Insufficient draft Add more pipe Let air stabilize before opening door Ensure baffles are pos...

Страница 36: ...sibility of NAPOLEON NAPOLEON reserves the right to have its representative inspect any product or part thereof prior to honouring any warranty claim All parts replaced under the President s Limited L...

Страница 37: ...37 W415 0763 B 10 28 11 43 1 12 0 SERVICE HISTORY...

Страница 38: ...38 W415 0763 B 10 28 11 13 0 NOTES 44 1...

Страница 39: ...39 W415 0763 B 10 28 11 44 1...

Страница 40: ...40 W415 0763 B 10 28 11 44 1...