Napoleon BGNV36N Скачать руководство пользователя страница 19

19

W415-0275 / E / 07.13.10

8.0 OPERATION

Ensure that a continuous gas flow is at the burner before installing the door. When lit for the first time, the appliance will 
emit an odor for a few hours. This is a normal temporary condition caused by the "burn-in" of paints and lubricants used in 
the manufacturing process and will not occur again. 
After extended periods of non-operation such as following a vacation or a warm weather season, the appliance may emit a 
slight odor for a few hours. This is caused by dust particles in the heat exchanger burning off. In both cases, open a 
window to sufficiently ventilate the room.

FOR YOUR SAFETY READ BEFORE LIGHTING:

A. 

  This appliance is equipped with a pilot which must be lit by hand while following these instructions exactly.

B.

   Before operating smell all around the appliance area for gas and next to the floor because some gas is heavier than 

       air and will settle on the floor.

C. 

  Use only your hand to turn the gas control knob. Never use tools. If the knob will not turn by hand, do not try to 

       repair it. Call a qualified service technician. Force or attempted repair may result in a fire or explosion.

D.

   Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect 

       the appliance and replace any part of the control system and any gas control which has been under water.

‡

Turn off all gas to the appliance.

‡

Open windows.

‡

Do not try to light any appliance.

‡

Do not touch any electric switch; do not use any 

    phone in your building.

GAS KNOB

WARNING: The gas valve has an interlock device which will not allow the pilot burner to be lit until the thermo-
couple has cooled. Allow approximately 60 seconds for the thermocouple to cool.

When lighting and re-lighting, the gas knob cannot be turned from pilot to off unless the knob is depressed slightly.

1.

   Stop! Read the above safety information on this label.

2.

   Turn off all electric power to the appliance.

3. 

  Turn the gas knob clockwise            to off.

4.

   Wait five (5) minutes to clear out any gas. If you smell gas including near the floor. Stop! Follow "B" in the 

      above safety information on this label. If you don't smell gas go the next step.

5.

   Turn gas knob counter-clockwise            to pilot.

6.

   Depress slightly and hold gas knob while lighting the pilot with the push button igniter. Keep knob depressed for one 

      minute, then release. If pilot does not continue to burn, repeat steps 3 through 5.

7. 

  With pilot lit, depress and turn gas knob counter-clockwise            to on.

8.  

 If equipped with remote on-off switch / thermostat, main burner may not come on when you turn valve to on. Remote 

      switch must be in the on position to ignite burner.

9.

   Turn on all electric power to the appliance.

1.

   Turn off all electric power to the appliance if service is to be performed.

2. 

  Push in gas control knob slightly and turn clockwise           to off. Do not force.

‡

Immediately call your gas supplier from a 

    neighbor's phone. Follow the gas 
    supplier's instructions.

‡

If you cannot reach your gas supplier, 

    call the fire department.

WHAT TO DO IF YOU SMELL GAS:

LIGHTING INSTRUCTIONS:

TO TURN OFF GAS

TURN THE CONTROL VALVE TO THE OFF POSITION WHEN HEATER IS NOT IN USE.

47.2

IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT 

CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. 

ALWAYS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPLY HAS RUN OUT WITH 

THE GLASS DOOR OPENED OR REMOVED.

!

WARNING

Содержание BGNV36N

Страница 1: ...Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electri...

Страница 2: ...AT 10 5 0 FRAMING 11 5 1 MINIMUM CLEARANCE TO COMBUSTIBLES 12 5 2 MINIMUM MANTEL CLEARANCES 13 5 3 NAILING TAB INSTALLATION 13 6 0 FINISHING 14 6 1 DOOR INSTALLATION REMOVAL 14 6 2 LOG PLACEMENT 15 6...

Страница 3: ...s see LOUVRE INSTALLATION section Glass see DOOR GLASS REPLACEMENT section Door see DOOR INSTALLATION REMOVAL section Logo see LOGO PLACEMENT section Logs see LOG PLACEMENT section Vent see VENTING se...

Страница 4: ...y safety screen or guard removed for servicing must be replaced prior to operating the appliance This appliance is a vented gas fired appliance Do not burn wood or other materials in this appliance It...

Страница 5: ...HE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPLY HAS RAN OUT WITH THE GLASS DOOR OPENED OR REMOVED PROVIDE ADEQUATE CLEARANCE FOR SERVICING AND OPERATING THE APPLIANCE PROVIDE ADEQUATE VENTILA...

Страница 6: ...ptional fan or blower is installed the junction box must be electrically connected and grounded in accordance with local codes use the current CSA C22 1 Canadian Electrical Code in Canada or the ANSI...

Страница 7: ...ONTACTAVEC LES FLAMMESAUTRE QUE CELUI QUI EST FOURNIAVEC CETAPPAREIL PAR LE FABRICANT THE APPLIANCE MUST BE VENTED USING B VENT SEE OWNERS INSTALLATION MANUAL FOR VENTING SPECIFICS L APPAREIL DOIT EVA...

Страница 8: ...vent and an insulated chase is recommended Under extreme vent configurations allow several minutes 5 15 for the flame to stabilize after ignition Provide a means for visually checking the vent connect...

Страница 9: ...ppliance blower off if so equipped 3 3 2 Set controls to high and light the appliance 3 3 3 Wait 5 minutes Light a match and hold to the front of the draft hood Venting action is satisfactory if smoke...

Страница 10: ...AS SUPPLY PIPE TO PREVENT DAMAGING GAS LINE ALWAYS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPLY HAS RUN OUT WITH THE GLASS DOOR OPENED OR REMOVED PURGING OF THE GAS SUPPLY LINE SHOU...

Страница 11: ...E GLASS OR PLASTERS OR ANY COM BINATION THEREOF ARE SUITABLE MATERIALS THAT ARE REPORTED AS PASSING ASTM E 136 STANDARD TEST METHOD FOR BEHAVIOUR OF MATERIALS IN A VERTICAL TUBE FURNACE AT 750 C AND U...

Страница 12: ...12 W415 0275 E 07 13 10 37 3 13 5 36 5 1 MINIMUM CLEARANCE TO COMBUSTIBLES 3 6 1 2 5 2 36 3 4 36 1 2 36 1 2 6 2 MIN 13 1 2 INSIDE CHASE OUTSIDE CHASE 13 1 2...

Страница 13: ...4 2 4 10 8 12 12 8 10 7 MANTLE 6 2 4 6 7 TOP OF UNIT COMBUSTIBLE MATERIALS 2x4 2 4 5 3 NAILING TAB INSTALLATION 55 1A Attach the nailing tabs to the corner posts using the 2 sheet metal screws sup pli...

Страница 14: ...OPENINGS LOUVRES OPENINGS OPERATION OF LOUVRES OR DOORS OR ACCESS FOR SERVICE OBSERVE ALL CLEARANCES WHEN APPLYING COMBUSTIBLE MATERIALS BEFORE DOOR IS REMOVED TURN THE APPLIANCE OFF AND WAIT UNTIL AP...

Страница 15: ...n front of the tabs The tabs maintain an air space between the log and firebox back to facilitate com bustion air flow Ensure that the back of the log rests against the brackets on the back wall of th...

Страница 16: ...ect flame Use only certified glowing embers and PHAZERTM logs available from your Continental dealer 32 1 Randomly place the charcoal embers along the front and sides of the log support tray in a real...

Страница 17: ...United States If the appliance was not previously equipped with a blower Route a grounded 2 wire 60hz power cable to the receptacle junction box At this point it must be strain relieved and insulated...

Страница 18: ...wer is thermally activated when turned on it will automatically start approximately 10 minutes after lighting the appliance and will run for approximately 30 45 minutes after the appliance has been tu...

Страница 19: ...ot burner to be lit until the thermo couple has cooled Allow approximately 60 seconds for the thermocouple to cool When lighting and re lighting the gas knob cannot be turned from pilot to off unless...

Страница 20: ...heck that main burner is operating on HI AFTER TAKING PRESSURE READINGS TIGHTEN SCREWS FIRMLY TO SEAL DO NOT OVER TORQUE LEAK TEST 39 3 P I P I L O T N O L O T HI L O F F O A B PILOT SCREW PILOT BURNE...

Страница 21: ...e area surrounding the logs clean by vacuuming or brushing at least once a year 3 Check to see that all burner ports are burning Clean out any of the ports which may not be burning or are not burning...

Страница 22: ...DO NOT TOUCH GLASS UNTIL COOLED CARE MUST BE TAKEN WHEN REMOVING AND DISPOSING OF ANY BROKEN DOOR GLASS OR DAMAGED COMPONENTS BE SURE TO VACUUM UP ANY BROKEN GLASS FROM INSIDE THE APPLIANCE BEFORE OPE...

Страница 23: ...IN PROPERTY DAMAGE OR PERSONAL INJURY WARNING COMMON COMPONENTS REF NO BGNV36 DESCRIPTION 1 W357 0001 PIEZO IGNITOR 2 W680 0004 THERMOPILE 3 W680 0005 THERMOCOUPLE 4 W010 0764 BURNER 5 W010 0800 NATUR...

Страница 24: ...GOLD PLATED 34 HOISS 3 HERITAGE ORNAMENTAL INSETS SATIN CHROME 35 DK36 R DOOR KIT RECTANGULAR BLACK 36 DK36 A DOOR KIT ARCHED BLACK 36 DK36 AG DOOR KIT ARCHES GOLD PLATED 37 DK36 W DOOR KIT WEBBED BL...

Страница 25: ...25 W415 0275 E 07 13 10 5 3 8 2 14 13 37 36 33 1 28 4 9 15 30 32 6 7 40 18 23 24 22 20 21 19 34 35 38...

Страница 26: ...nob is on HI wall switch thermostat is on Thermostat or switch is defective Connect a jumper wire across the wall switch terminals if main burner lights replace switch thermostat Wall switch wiring is...

Страница 27: ...re increase fresh air supply Carbon is being deposited on glass logs or combustion chamber surfaces Air shutter has become blocked Ensure air shutter opening is free of lint or other obstructions Flam...

Страница 28: ...of NAPOLEON with respect to the NAPOLEON gas heater and any other warranties expressed or implied with respect to this product its components or accessories are excluded NAPOLEON neither assumes nor a...

Страница 29: ...29 W415 0275 E 07 13 10 14 0 SERVICE HISTORY 43 1...

Страница 30: ...30 W415 0275 E 07 13 10 44 1 15 0 NOTES...

Страница 31: ...31 W415 0275 E 07 13 10 44 1...

Страница 32: ...32 W415 0275 E 07 13 10 44 1...

Отзывы: