W415-0811 / A / 04.28.10
8.2.3 APPLIANCE VENT CONNECTION
A.
Install the inner
fl
ex pipe to the appliance. Secure with 3 screws
and
fl
at washers. Seal the joint and screw holes using the high
temperature sealant W573-0007 (not supplied).
B.
Install the outer
fl
ex pipe to the appliance. Attach and seal
the joints using the high temperature sealant W573-0002 (not
supplied).
28.2
2” OVERLAP
#8 X 1/2”
SELF
DRILLING
SCREWS
HIGH TEMPERATURE
SEALANT
8.3 GAS
INSTALLATION
30.1A
Installation and servicing to be done by a quali
fi
ed installer.
Do not use open fl ame.
•
Move the appliance into position and secure.
•
If equipped with a
fl
ex connector the appliance is designed to accept a 1/2” gas supply. Without the
connector it is designed to accept a 3/8” gas supply. The appliance is equipped with a manual shut off
valve to turn off the gas supply to the appliance.
•
Connect the gas supply in accordance to local codes. In the absence of local codes, install to the
current CAN/CSA-B149.1 Installation Code in Canada or to the current National Fuel Gas Code, ANSI
Z223.1 / NFPA 54 in the United States.
• When
fl
exing any gas line, support the gas valve so that the lines are not bent or kinked.
•
The gas line
fl
ex-connector should provide suf
fi
cient movement to permit shifting the burner assembly
on it’s side.
•
Check for gas leaks by brushing on a soap and water solution.
!
WARNING
RISK OF FIRE, EXPLOSION OR ASPHYXIATION. ENSURE THERE ARE NO IGNITION SOURCES SUCH
AS SPARKS OR OPEN FLAMES.
SUPPORT GAS CONTROL WHEN ATTACHING GAS SUPPLY PIPE TO PREVENT DAMAGING GAS LINE.
ALWAYS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPLY HAS RUN OUT
WITH THE GLASS DOOR OPENED OR REMOVED. PURGING OF THE GAS SUPPLY LINE SHOULD BE
PERFORMED BY A QUALIFIED SERVICE TECHNICIAN. ASSURE THAT A CONTINUOUS GAS FLOW IS AT
THE BURNER BEFORE CLOSING THE DOOR. ENSURE ADEQUATE VENTILATION. FOR GAS AND
ELECTRICAL LOCATIONS, SEE “DIMENSION” SECTION.
ALL GAS CONNECTIONS MUST BE CONTAINED WITHIN THE APPLIANCE WHEN COMPLETE.
HIGH PRESSURE WILL DAMAGE VALVE. DISCONNECT GAS SUPPLY PIPING BEFORE TESTING GAS
LINE AT TEST PRESSURES ABOVE 1/2 PSIG.
VALVE SETTINGS HAVE BEEN FACTORY SET, DO NOT CHANGE.
7.3.1
7.3.2
7.3.3
7.3.4
7.3.5
7.3.6