background image

34

W415-0299 / C / 03.12.03

Wolf Steel Fireplace Service History

This fireplace must be serviced annually depending on usage.

Date

Service Technician

 Name

Service Performed

Special Concerns

Dealer Name

Содержание BGD40-N

Страница 1: ...Z21 88 FOR VENTED GAS FIREPLACE HEATERS WARNING If the information in these instructions is not followed exactly a fire or explosion may result causing property damage personal injury or death FOR YO...

Страница 2: ...ildren when they are in the same room as the fireplace Due to high temperatures the fireplace should be located out of traffic and away from furniture and draperies Clothing or other flammable materia...

Страница 3: ...fficial Labour costs to the however requires the prior approval of an authorized company official Labour costs to the account of account of account of account of account of NAPOLEON NAPOLEON NAPOLEON...

Страница 4: ...nches FOR YOUR SATISFACTION ALL BURNER ASSEMBLIES HAVE BEEN TEST FIRED TO ASSURE THEIR OPERA TIONS AND QUALITY Maximum input is 30 000 BTU h for natural gas and propane When the fireplace is installed...

Страница 5: ...rawl spaces should be insulated with the insulation wrapped in a protective sleeve to minimize condensation Objects placed in front of the fireplace must be kept a minimum of 48 away from the glass fr...

Страница 6: ...ions when using aluminum flex ible venting For optimum flame appearance and fireplace perform ance keep the vent length and number of elbows to a minimum The air terminal must remain unobstructed at a...

Страница 7: ...en Clearance to permanently closed windows Vertical clearance to ventilated soffit located above the terminal within a horizontal distance of 2 feet from the centerline of the terminal Clearance to un...

Страница 8: ...e vertical rise is less than is less than is less than is less than is less than horizontal horizontal horizontal horizontal horizontal run run run run run horizontal horizontal horizontal horizontal...

Страница 9: ...f fireplace as illustrated When venting the horizontal run must be kept to a mini mum of 10 inches or a maximum of 20 feet If a 20 foot horizontal run is required the fireplace must have a mini mum ve...

Страница 10: ...6 0 30 0 9 11 0 45 1 35 16 0 90 2 7 32 0 the first 45 and 90 offset has a zero value and is shown in the formula as 45 and 90 respectively or 135 when combined For vent configurations requiring more t...

Страница 11: ...HT VT Simple venting configuration only one 45 and 90 elbow Example 2 V1 4ft VT V1 4 ft H1 2ft H2 1ft H3 1ft H4 1 5ft HR H1 H2 H3 H4 2 1 1 1 5 5 5 ft HO 03 one 45 elbow three 90 elbow 135 03 315 135...

Страница 12: ...onfiguration is ac ceptable when HT VT Simple venting configurations FIGURE9 REQUIRED VERTICAL RISE IN FEET VT HORIZONTAL VENT RUN PLUS OFFSETS IN FEET HT FIGURE10 For vent configurations requiring mo...

Страница 13: ...40 feet 15 9 40 Since only formula 2 is met this vent configuration is unac ceptable and a new fireplace location or vent configuration will need to be established to satisfy both formulas Example 5 V...

Страница 14: ...e fireplace face flush with the finished wall position the framework to accommodate the thickness of the finished wall Care should be taken to maintain sufficient clearance for the vent installation A...

Страница 15: ...ned for will interfere with the opening of the lower access door and the installation of many decorative flashing accessories Objects placed in front of the fireplace should be kept a minimum of 48 aw...

Страница 16: ...in position bend down the tab to secure DE TAIL 6 A A 25 minus finishing material thickness each side FIGURES21a c FIGURE20 Combustible materials may be installed flush with the front of the fireplac...

Страница 17: ...TAIL5 6 Combustible materials may be installed flush with the front of the fireplace but must not cover any of the black face areas of the fireplace Non combustible material brick stone or ceramic til...

Страница 18: ...d all venting options See pages 14 17 FIGURE26 FIGURE27 Horizontal Vent Off Fireplace Vertical Vent Off Fireplace A 42 using flexible vent components A 38 using Wolf Steel rigid vent components B 45 u...

Страница 19: ...s to or der the specific kit re quired 1 Determine the air ter minal location cut and frame 10 inch open ings in the ceiling and the roof to provide the minimum clearance be tween the fireplace pipe l...

Страница 20: ...er tight by sealing with caulking not supplied 6 If more liner needs to be used to reach the fireplace couple them together as illustrated The vent system must be supported approximately every 3 feet...

Страница 21: ...taking into account the additional length needed for the finished wall surface and any 1 overlaps between venting compo nents 2 Apply high temperature sealant to the outer edge of the 5 inner collar...

Страница 22: ...lar is achieved Attach the other storm collar centered between the air intake and air exhaust slots onto the air terminal Tighten securely Attach the rain cap 8 Continue adding rigid venting sections...

Страница 23: ...ce 3a is the base of log 3 The base sits diagonally in the designated area lo cated between logs 1 and fits tight up against 2 4 The slot in the under side of piece 3b fits over 3a Place the end of pi...

Страница 24: ...them Fine dust found in bottom of bag not to be used PHAZERTM logs and embers glow when exposed to direct flame Use only certified PHAZERTM logs glowing embers and char coal embers available from you...

Страница 25: ...TION FIGURE 57 L36 LOUVRE INSTALLATION FIGURE 54a c HOOD Attach the hood by pressing the top flange into the clips along the top of the louvre opening Secure using a screw through the centre slot LOWE...

Страница 26: ...automatically start approximately 10 minutes after lighting the fireplace and will run for approximately 30 45 minutes after the fireplace has been turned off Use of the fan increases the output of he...

Страница 27: ...information on this label If you don t smell gas go the next step 5 Turn gas knob counter clockwise to pilot 6 Depress slightly and hold gas knob while lighting the pilot with the push button ignitor...

Страница 28: ...final flame colour to be established FIGURE66 FIGURE64 FIGURE65 AIR SHUTTER ADJUSTMENT MUST ONLY BE DONE BYA QUALIFIEDGASINSTALLER WARNING This is a fast act ing thermocouple It is an in tegral safety...

Страница 29: ...0 0801 NATURAL GAS PILOT ASSEMBLY 35 W010 0800 PROPANE GAS PILOTASSEMBLY 36 W455 0069 NATURAL GAS PILOT INJECTOR 36 W455 0067 PROPANE GAS PILOT INJECTOR 37 W660 0005 BURNER ON OFF SWITCH 38 W680 0004...

Страница 30: ...30 W415 0299 C 03 12 03 WARNING This is a fast acting thermocouple It is an integral safety component Replace only with a fast acting thermocouple supplied by Wolf Steel Ltd...

Страница 31: ...SET BRUSHED COPPER PLATED 17 DOIBG 1 DIAMOND ORNAMENTAL INSET BRUSHED GOLD PLATED 18 EDOIG 1 END DIAMOND ORNAMENTAL INSET GOLD PLATED 18 EDOIKG 1 END DIAMOND ORNAMENTAL INSET BLACK GOLD PLATED 18 EDOI...

Страница 32: ...L O F F O Main burner flame is a blue lazy t r a n s p a r e n t flame Blockage in vent remove blockage In really cold conditions ice buildup may occur on the terminal and should be removed as require...

Страница 33: ...needs tightening replace the wire if the wire insulation is broken or frayed replace the electrode if the ceramic insulator is cracked or broken replace the push button ignitor No spark at pilot burn...

Страница 34: ...34 W415 0299 C 03 12 03 Wolf Steel Fireplace Service History This fireplace must be serviced annually depending on usage Date Service Technician Name Service Performed Special Concerns Dealer Name...

Страница 35: ...35 W415 0299 C 03 12 03 NOTES...

Страница 36: ...36 W415 0299 C 03 12 03 NOTES...

Отзывы: