11
W415-0299 / C / 03.12.03
See graph to determine the re-
quired vertical rise V
T
for the required
horizontal run H
T
.
For vent configurations requiring more than one 45º and
90° elbow the following formulas apply:
Formula 1: H
T
< 4.2 V
T
Formula 2: H
T
+ V
T
< 24.75 feet
FIGURE 7
REQUIRED
VERTICAL
RISE IN
INCHES (V
T
)
HORIZONTAL VENT RUN PLUS OFFSETS IN FEET (HT)
when
(H
T
)
>
(V
T
)
Simple venting configuration (only one 45º and 90° elbow)
Example 2:
V
1
= 4 ft
V
T
=
V
1
= 4 ft
H
1
= 2 ft
H
2
= 1 ft
H
3
= 1 ft
H
4
= 1.5 ft
H
R
=
H
1
+
H
2
+
H
3
+
H
4
= 2 + 1 + 1 + 1. 5 = 5.5 ft
H
O
= .03(one 45º elbow + three 90º elbow -135º)
=.03(315-135)=5.4ft
H
T
=
H
R
+
H
O
= 5.5 +5.4 = 10.9 ft
H
T
+ V
T
= 10.9 + 4 = 14.9 ft
Formula 1:
H
T
< 4.2 V
T
4.2 V
T
= 4.2 x 4 = 16.8 ft
10.9 < 16.8
Formula 2:
H
T
+ V
T
< 24.75 feet
14.9 < 24.75
Since both formulas are met, this vent configuration is ac-
ceptable.
H
4
V
1
90°
H
3
H
1
90°
H
2
90°
FIGURE 8
45°
The shaded area within the lines represents acceptable
values for H
T
and V
T
.
HORIZONTAL TERMINATION