3.0  VENTING

7.1

THIS APPLIANCE USES A 4” (102mm) EXHAUST / 7” (178mm) AIR INTAKE VENT PIPE SYSTEM.

Refer to the section applicable to your installation. 

For safe and proper operation of the appliance, follow the venting instruction exactly. Deviation from the minimum vertical 

vent length can create diffi culty in burner start-up and/or carboning. Under extreme vent confi gurations, allow several 

minutes (5-15) for the fl ame to stabilize after ignition. Although not a requirement, it is recommended for vent lengths that 

pass through unheated spaces (attics, garages, crawl spaces) be insulated with the insulation wrapped in a protective sleeve 

to minimize condensation. Provide a means for visually checking the vent connection to the appliance after the appliance is 

installed. Use a fi restop, vent pipe shield or attic insulation shield when penetrating interior walls, fl oor or ceiling.
The vent terminal may be painted with a high temperature paint to match exterior colours. Use an outdoor paint suitable 

for 400°F (200°C). Application and performance of paint is the consumer’s responsibility. Spot testing is recommended.

NOTE: If for any reason the vent air intake system is disassembled; reinstall per the instructions provided for the 

initial installation.
NOTE: This appliance must be installed with a continuous connection of exhaust and air intake vent pipes. 

Utilizing alternate constructions such as a chimney as part of the vent system is not permitted.

Use only Wolf Steel, Simpson Dura-Vent, Selkirk Direct Temp, American Metal Amerivent or Metal-Fab venting 

components. Minimum and maximum vent lengths, for both horizontal and vertical installations, clearances from vent 

pipes to combustibles and air terminal locations as set out in this manual apply to all vent systems and must be adhered 

to. For Simpson Dura-Vent, Selkirk Direct Temp, American Metal Amerivent and Metal-Fab, follow the installation 

procedure provided with the venting components or on the website for your venting supplier. 
A starter adaptor must be used with the following vent systems and may be purchased from the corresponding supplier:

For vent systems that provide seals on the inner exhaust fl ue, only the outer air intake joints must be sealed using a red 

high temperature silicone (RTV). This same sealant may be used on both the inner exhaust and outer intake vent pipe 

joints of all other approved vent systems except for the exhaust vent pipe connection to the appliance fl ue collar which 

must be sealed using the black high temperature sealant Mill Pac. High temperature sealant must be ordered separately. 
When using Wolf Steel venting components, use only approved Wolf Steel rigid / fl exible components with the following 

termination kits: wall terminal kit 

GD-222

GD-222R

, or 1/12 to 7/12 pitch roof terminal kit 

GD-110

, 8/12 to 12/12 roof 

terminal kit 

GD-111

, fl at roof terminal kit 

GD-112

 or periscope kit 

GD-201 

(for wall penetration below grade). With fl exible 

venting, in conjunction with the various terminations, use either the 5 foot (1.5m) vent kit 

GD-220

 or the 10 foot  (3.1m) 

vent kit

 GD-330

. For stoves only: wall terminal kit 

GD175

 (venting included). 

For optimum fl ame appearance and appliance performance, keep the vent length and number of elbows to a minimum.
The air terminal must remain unobstructed at all times. Examine the air terminal at least once a year to verify that 

it is unobstructed and undamaged.
Rigid and fl exible venting systems must not be combined. Different venting manufacturer components must not 

be combined.

These vent kits allow for either horizontal or vertical venting of the appliance. The maximum allowable horizontal run is 20 

feet (6.1m). The maximum allowable vertical vent length is 40 feet (12.2m). The maximum number of vent connections is 

two horizontally or three vertically (excluding the appliance and the air terminal connections) when using fl exible venting.
A terminal shall not terminate directly above a sidewalk or paved driveway which is located between two single family dwellings 

and serves both dwellings. Local codes or regulations may require different clearances.

For stoves only: deviation from the minimum vertical vent length can create diffi culty in burner start-up and/or 

carboning. Use an adjustable pipe as the fi nal length of rigid piping to the stove for ease of installation.

VENT 

MANUFACTURER

STARTER ADAPTER 

PART NUMER

SUPPLIER

WEBSITE

Duravent

W175-0053

Wolf Steel

www.duravent.com

Amerivent

4DSC-N2

American Metal

www.americanmetalproducts.com

Direct Temp

4DT-AAN

Selkirk 

www.selkirkcorp.com

SuperSeal

4DNA

Metal-Fab

www.mtlfab.com

!

WARNING

RISK OF FIRE, MAINTAIN SPECIFIED AIR SPACE CLEARANCES TO VENT PIPE AND APPLIANCE.

IF VENTING IS INCLUDED WITH SPACERS THE VENT SYSTEM MUST BE SUPPORTED EVERY 3FT (0.9m) FOR 

BOTH VERTICAL AND HORIZONTAL RUNS. USE SUPPORTS OR EQUIVALENT  NON-COMBUSTIBLE STRAPPING 

TO MAINTAIN THE REQUIRED CLEARANCE FROM  COMBUSTIBLES. USE WOLF STEEL LTD. SUPPORT RING 

ASSEMBLY W010-0370 OR EQUIVALENT NON-COMBUSTIBLE STRAPPING TO MAINTAIN THE MINIMUM 

CLEARANCE TO COMBUSTIBLES  FOR BOTH VERTICAL AND HORIZONTAL RUNS. SPACERS ARE ATTACHED TO 

THE INNER PIPE AT PREDETERMINED INTERVALS TO MAINTAIN AN EVEN AIR GAP TO THE OUTER PIPE. THIS GAP 

IS REQUIRED FOR SAFE OPERATION. A SPACER IS REQUIRED AT THE START, MIDDLE AND END OF EACH ELBOW 

TO ENSURE THIS GAP IS MAINTAINED. THESE SPACERS MUST NOT BE REMOVED. 

W415-2207 / A / 08.28.17

8  

EN

Содержание Bayfield GDS25N-1

Страница 1: ...an aftermarket permanently located manufactured home USA only or mobile home where not prohibited by local codes This appliance is only for use with the type of gas indicated on the rating plate This...

Страница 2: ...BARRIER INSTALLATION AND REMOVAL 26 5 3 GLASS DOOR INSTALLATION AND REMOVAL 27 5 4 LOG PLACEMENT 27 5 5 LOGO PLACEMENT 28 6 0 OPTIONAL BLOWER INSTALLATION 29 7 0 WIRING DIAGRAM 31 8 0 OPERATION 32 8...

Страница 3: ...lower see OPTIONAL BLOWER INSTALLATION section Rating plate see RATING PLATE INFORMATION section Batteries must be disposed of according to the local laws and regulations Some batteries may be recycle...

Страница 4: ...sh air If appliance keeps shutting off have it serviced Keep burner and control compartment clean Under no circumstances should this appliance be modified Do not allow wind or fans to blow directly in...

Страница 5: ...sting of that system at test pressures in excess of 1 2 psig 35 mb The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure t...

Страница 6: ...ertified high altitude input rating shall be reduced at the rate of 4 for each additional 1 000ft 305m Expansion contraction noises during heating up and cooling down cycles are normal and to be expec...

Страница 7: ...ly Refer to the rating plate on the appliance for accurate information NOTE The rating plate must remain with the appliance at all times It must not be removed A barrier designed to reduce the risk of...

Страница 8: ...ing Wolf Steel venting components use only approved Wolf Steel rigid flexible components with the following termination kits wall terminal kit GD 222 GD 222R or 1 12 to 7 12 pitch roof terminal kit GD...

Страница 9: ...EGARDLESS OF HORIZONTAL VENT LENGTH 40FT 12m MAX 3FT 1m MIN The maximum horizontal run with a 57 1 45m vertical rise immediately above the appliance is 20 feet 6 1m 16 40 6cm 25 5 8 65 1cm 25 5 8 65 1...

Страница 10: ...able vent length is 10 3 1m for a fireplace and 8 2 4m for a stove 8 2 3 1 SPECIAL VENT INSTALLATIONS 3 1 1 PERISCOPE TERMINATION 3 1 2 CORNER TERMINATION 12 305mm MIN TO GRADE BELOW GRADE INSTALLATIO...

Страница 11: ...veranda porch deck or balcony N 16 40 6cm 16 40 6cm Clearance above the roof O 2 0 6m 2 0 6m Clearance from an adjacent wall including neighbouring buildings P 8 2 4m 8 2 4m Roof must be non combusti...

Страница 12: ...for 45 exit only 3 4 ELBOW VENT LENGTH VALUES 3 3 DEFINITIONS 11 1 For the following symbols used in the venting calculations and examples are greater than equal to or greater than less than equal to...

Страница 13: ...4m HO 03 one 45 elbow two 90 elbows 135 03 225 135 2 7 FT 0 8m HT HR HO 4 5 FT 1 4m 2 7 FT 0 8m 7 2 FT 2 2m HT VT 7 2 FT 2 2m 8 FT 2 4m 15 2 FT 4 6m Formula 1 HT VT 7 2 FT 2 2m 8 FT 2 4m Formula 2 HT...

Страница 14: ...VT 4 2 FT 1 3m x 5 5 FT 1 7m 23 1 FT 7m 13 6 FT 4 2m 23 1 FT 7M Formula 2 HT VT 24 75 FT 7 5m 19 1 FT 5 8m 24 75 FT 7 5m Since both formulas are met this vent configuration is acceptable 90 90 45 V1...

Страница 15: ...10 FT 3 1m 15 FT 4 6m H1 3 FT 0 9m H2 2 5 FT 0 8m HR H1 H2 3FT 0 9m 2 5FT 0 8m 5 5 FT 1 7m HO 03 one 45 three 90 elbows 135 03 45 270 135 5 4 FT 1 6m HT HR HO 5 5 FT 1 7m 5 4 FT 1 m 10 9 FT 3 3m HT V...

Страница 16: ...4m 5 4FT 1 6m 13 4FT 4 1m HT VT 13 4FT 4 1m 2 5FT 0 8m 15 9FT 4 8m Formula 1 HT 3VT 3VT 3FT 0 9m x 2 5FT 0 8m 7 5FT 2 3m 13 4 FT 4 1m 7 5 FT 2 3m Since this formula is not met this vent configuration...

Страница 17: ...quired directly off the appliance Follow vent manufacturer s installation instructions Different manufacturer s venting components must not be combined Once the preferred manufacturer s appliance adap...

Страница 18: ...3 SCREWS MUST ALSO BE USED TO ENSURE THE CONNECTION CANNOT SLIP OFF DO NOT CLAMP THE FLEXIBLE VENT PIPE RISK OF FIRE EXPLOSION OR ASPHYXIATION IMPROPER SUPPORT OF THE ENTIRE VENTING SYSTEM MAY ALLOW V...

Страница 19: ...ver up the open end of the shield and tighten This will prevent any materials such as insulation from filling up the 1 25mm air space around the pipe FIRESTOP UNDERSIDE OF JOIST CAULKING VENT PIPE SHI...

Страница 20: ...wall or siding no greater than the depth of its return flange 18 1 Screws Supplied 2 50 8mm Overlap Outer Flex Pipe Inner Flex Pipe Red RTV Silicone Caulking Screws Supplied 2 50 8mm Overlap Outer Fl...

Страница 21: ...g over the air terminal connector leaving a min 3 4 19mm of the air terminal connector showing above the top of the flashing Slide the flashing underneath the sides and upper edge of the shingles Ensu...

Страница 22: ...anada or to the current National Fuel Gas Code ANSI Z223 1 NFPA 54 in the United States D When flexing any gas line support the gas valve so that the lines are not bent or kinked E The gas line flex c...

Страница 23: ...opriate securing kit For mobile home installations the appliance must be fastened in place It is recommended that the appliance be secured in all installations Always turn off the pilot and the fuel s...

Страница 24: ...apoleon appliance is in the centre of a building thereby allowing the most ef cient use of the heat created The location of windows doors and the traf c ow in the room where the appliance is to be loc...

Страница 25: ...WITH THESE INSTRUCTIONS MAY CAUSE A FIRE OR CAUSE THE APPLIANCE TO OVERHEAT ENSURE ALL CLEARANCES I E BACK SIDE TOP VENT HEARTH MANTEL FRONT ETC ARE CLEARLY MAINTAINED WARNING W415 1332 A 11 21 14 25...

Страница 26: ...o scratch the bottom casting D Reverse these steps to remove WARNING GLASS MAY BE HOT DO NOT TOUCH GLASS UNTIL COOLED 5 0 FINISHING 5 1 CAST FRONT INSTALLATION AND REMOVAL A Remove safety barrier B Li...

Страница 27: ...EWS BRACKET It is not necessary to remove the cast front however this will make for a more simple log installation In order to assemble the log set the glass door must be removed see CAST FRONT GLASS...

Страница 28: ...front of and against the right end of log 2 D Reinstall the glass door front 5 6 LOGO PLACEMENT 5 5 1 SWITCH FUNCTIONS W415 1332 A 11 21 14 Remove the backing from the logo and position onto the contr...

Страница 29: ...S BED CARRIAGES OR PLAY PENS THIS BAG IS NOT A TOY KNOT BEFORE THROWING AWAY A Disconnect power supply from the appliance B Open the control door located at the bottom front of the appliance Figure 1...

Страница 30: ...o rear hole of housing H Place blower housing close to the rear of the appliance Route wire through hole in blower housing and connect the spade connectors to blower Figure 7 I Align the blower to the...

Страница 31: ...ng plug for protection against shock hazard and should be connected into a properly grounded circuit Do not cut or remove the grounding prong from the plug This appliance must be electrically connecte...

Страница 32: ...the access panel G Wait five 5 minutes to clear out any gas If you smell gas including near the floor STOP Follow B in the above safety information on this label If you don t smell gas go to the next...

Страница 33: ...as shown in the illustration below D The battery holder will beep 3 times to indicate that it s ready to synchronize with the transmitter E Install the 3 AAA batteries into the transmitter as shown in...

Страница 34: ...F 76 F Hi FLAME OFF FLAME AT LEVEL 1 FLAME AT LEVEL 5 FLAME AT HI LEVEL 6 35 8A If the appliance is equipped with a hot air circulating fan the speed of the fan can be controlled by the remote system...

Страница 35: ...egardless of what is set on the remote control handset 35 22 76 F IPI 76 F CPI This function will lock the keys to avoid unsupervised operation A Press the MODE and UP keys at the same time B To de ac...

Страница 36: ...ow no beep will be emitted from the receiver when it receives an ON OFF command This in an alert for the receiver that there s low battery When the batteries are replaced the beep will be emitted from...

Страница 37: ...TRICTOR SHOWN IN A FULLY OPEN POSITION RESTRICTOR SHOWN IN A FULLY CLOSED POSITION Vertical installations may display a very active flame Loosen the two screws and slide the restrictor plate block ing...

Страница 38: ...on Prior to pilot adjustment ensure that the pilot assembly has not been painted If overspray or painting of the pilot assembly has occurred remove the paint from the pilot assembly or replace Fine em...

Страница 39: ...ue to excessive lint dust from carpeting pets etc simply vacuum using the brush attachment 6 If your appliance is equipped with relief doors ensure the system performs effectively Check that the gaske...

Страница 40: ...gently remove any build up on the pilot assembly including if equipped thermopile thermocouple flame sensor and igniter NOTE Clean flame sensor using a fine emery cloth or a synthetic scrub pad such a...

Страница 41: ...ASSEMBLY This must be carried out by anAUTHORIZED REPRESENTATIVE OF WOLF STEEL LTD or a QUALIFIED GAS INSTALLER in accordance with local codes or in the absence of local codes with the requirements o...

Страница 42: ...vec l appareil et sera install pour la protection des enfants et d autres personnes risque LA VITRE CHAUDE CAUSERA DES BR LURES NE PAS TOUCHER LA VITRE AVANT QU ELLE AIT REFROIDI NE JAMAIS LAISSER LES...

Страница 43: ...7 18 10 W010 4177 W350 0342 W430 0013 W080 1786 W655 0239 W660 0009 W135 0257 W010 3685 W010 2020 W135 0232 14 12 13 7 FRONT CASTING SAFETY SCREEN DOOR ASSEMBLY CONTROL COVER ASSEMBLY BATTERY HOUSING...

Страница 44: ...R 14 W725 0057 VALVE P 17 18 PRO 2 WIRE HARNESS W750 0276 W750 0412 BLOWER LIGHT WIRE HARNESS BATTERY HOUSING WIRE HARNESS W750 0268 6 7 7 0 W660 0126 SER PRO 2 TRANSMITTER 10 W432 0078 3 8 MANIFOLD 1...

Страница 45: ...TONE BRICK PANEL GDS813KT 4 W090 0135 LS PORCELAIN PANEL PRP25 5 W090 0133 REAR PORCELAIN PANEL PRP25 6 W090 0134 RS PORCELAIN PANEL PRP25 7 8 GSB25KT BLOWER KIT GDSLL KT LEG LEVELING STOVE SECURING K...

Страница 46: ...s into the module Remove and verify continuity of each wire in wiring harness Module is not grounded Verify the valve and pilot assemblies are properly grounded to the metal chassis of the appliance o...

Страница 47: ...iring Connection Inspect all wires ensure good tight connections Verify that all wiring is installed exactly as specified Wiring harness Inspect the wiring harness and verify the harness is tightly co...

Страница 48: ...ds of dampness condensation damaging chemicals or cleaners will not be the responsibility of NAPOLEON All parts replaced under the President s Limited Lifetime Warranty Policy are subject to a single...

Страница 49: ...28 1 15 0 SERVICE HISTORY W415 2207 A 08 28 17 49 EN...

Страница 50: ...rie Ontario Canada L4M 0G8 214 Bayview Drive Barrie Ontario Canada L4N 4Y8 103 Miller Drive Crittenden Kentucky USA 41030 7200 Trans Canada Highway Montreal Quebec Canada H4T 1A3 NAPOLEON CELEBRATING...

Страница 51: ...avec le type de gaz indiqu sur la plaque d homologation Cet appareil ne peut tre converti d autres gaz sauf si une trousse de conversion est utilis e Si ces instructions ne sont pas suivies la lettre...

Страница 52: ...E PROTECTION 76 5 3 INSTALLATION ET ENL VEMENT DE LA PORTE VITR E 77 5 4 DISPOSITION DES B CHES 77 5 5 MISE EN PLACE DU LOGO 78 6 0 INSTALLATION DE LA SOUFFLERIE OPTIONNELLE 79 7 0 SCH MA DE C BLAGE 8...

Страница 53: ...ans votre centre de recyclage local Rensei gnez vous aupr s de votre municipalit au sujet des directives de recyclage Las bater as deben desecharse de acuerdo con las leyes y regulaciones locales Algu...

Страница 54: ...inflammables Si l appareil s teint n allume pas l appareil jusqu ce que vous donner de l air frais Si l appareil continue de s teindre faire r parer Garder propres le br leur et le compartiment de co...

Страница 55: ...es maisons mobiles quip es au gaz CAN CSA Z240 S RIE MM au Canada ou selon les normes ANSI Z223 1 et NFPA 54 aux tats Unis L alimentation de gaz de l appareil doit tre d branch e pendant les essais de...

Страница 56: ...duit au taux de 4 pour chaque 1 000 pieds 305m suppl mentaires Les bruits caus s par l expansion et la contraction lors des cycles de chauffage et de refroidissement sont tout fait normaux et il faut...

Страница 57: ...catif seulement Pour les renseignements exacts consultez la plaque d homologation fi x e sur l appareil NOTE Le plaque d homologation doit rester avec l appareil tout le temps Il ne doit pas tre enlev...

Страница 58: ...ment avec les ensembles de terminaison suivants les ensembles de terminaison murale GD222 GD222R ou l ensemble de terminaison pour toit de pente 1 12 7 12 GD110 l ensemble de terminaison pour toit de...

Страница 59: ...UR DE LA COURSE HORIZONTALE 40PI 12m MAX 3FT 1m MIN Lorsque la course verticale imm diatement la sortie de l appareil est de 57 1 45m alors la course hori zontale maximale est de 20 pieds 6m 16 40 6cm...

Страница 60: ...un foyer et 8 pieds 2 4m pour un po le 8 2 3 1 INSTALLATIONS PARTICULI RES D VENTS 3 1 1 ENSEMBLE P RISCOPIQUE 3 1 2 TERMINAISON EN COIN 12 305mm MINIMUM AU NIVEAU DU SOL INSTALLATION SOUS LE NIVEAU D...

Страница 61: ...adjacents incluant les maisons voisines P 8 2 4m 8 2 4m Le toit doit tre incombustible et sans ouvertures Q 3 0 9m 3 0 9m Voir le tableau pour les dimensions d un mur plus large R 6 1 8m 6 1 8m Voir l...

Страница 62: ...RS D VENT 3 3 L GENDE 11 1 Les symboles suivants sont utilis s dans le calcul et les exemples d vacuation plus grand que plus grand ou gal plus petit que plus petit ou gal HT total de la longueur des...

Страница 63: ...eptables pour HT et VT Lorsque la configuration de l vacuation exige plus qu un coude de 45 et de 90 les formules suivantes s appliquent Formule 1 HT VT Formule 2 HT VT 40 pieds 12 2m Exemple V1 8 PI...

Страница 64: ...PI 7m Formule 2 HT VT 24 75 PI 7 5m 19 1 PI 5 8m 24 75 PI 7 5m Puisque les deux formules sont respect es cette configuration d vacuation est acceptable H4 90 90 45 V1 H1 H2 COURSE VERTICALE REQUISE EN...

Страница 65: ...on de l vacuation exige plus qu un coude de 45 et un coude de 90 les formules suivantes s appliquent Formule 1 HT VT Formule 2 HT VT 40 pieds 12 2m Exemple V1 5 PI 1 5m V2 10 PI 3 1m VT V1 V2 5 PI 1 5...

Страница 66: ...PI 2 4m 5 4 PI 1 6m 13 4 PI 4 1m HT VT 13 4 PI 4 1m 2 5 PI 0 8m 15 9 PI 4 8m Formule 1 HT 3VT 3VT 3PI 0 9m x 2 5PI 0 8m 7 5PI 2 3m 13 4PI 4 1m 7 5PI 2 3m Puisque cette formule n est pas respect e cett...

Страница 67: ...l Suivez les instructions d installation du fabricant du syst me d vacuation Des composants d vacuation de diff rents fabricants ne doivent pas tre combin s Une fois que l adaptateur de votre choix es...

Страница 68: ...AUSSI INSTALLER TROIS VIS POUR VOUS ASSURER QUE LE RACCORDEMENT NE SE D FASSE PAS NE SERREZ PAS LA GAINE FLEXIBLE RISQUE D INCENDIE D EXPLOSION OU D ASPHYXIE SI L ENSEMBLE DU SYST ME DE CONDUIT D VEN...

Страница 69: ...d vacuation et l espaceur coupe feu C Dans le grenier faites glisser le collet de conduit d vacuation vers le bas afin de recouvrir l extr mit ouverte du protecteur de conduit d vacuation et serrez Ce...

Страница 70: ...1 Vis Vis Fournies 2 50 8mm Chevauchement Gaine flexible ext rieure int rieure Scellant haute temp rature Calfeutrage Scellant haute temp rature Vis Bague d accouplement int rieur et ext rieur Gaine f...

Страница 71: ...par dessus le connecteur de terminaison en laissant un minimum de 3 4 19 1mm de connecteur de terminaison visible au dessus du haut du solin Glissez le solin sous les c t s et le bord sup rieur des b...

Страница 72: ...absence de codes locaux l installation doit tre conforme au Code d installation du gaz CAN CSA B149 1 dans sa version pour le Canada ou le National Fuel Gas Code ANSI Z223 1 NFPA 54 pour les tats Uni...

Страница 73: ...ributeur permettant la s curisation kit Lors d une installation dans une maison mobile l appareil doit tre fix au plancher teignez toujours la veilleuse et l alimentation en gaz la source avant de d p...

Страница 74: ...s et la circulation dans la pi ce o se trouve l appareil devront tre pris en consid ration Si possible vous devriez choisir un emplacement o le syst me d vacuation peut passer travers la maison sans a...

Страница 75: ...PECTER CES INSTRUCTIONS PEUT CAUSER UN INCENDIE OU UNE SUR CHAUFFE ASSUREZ VOUS QUE TOUS LES D GAGEMENTS C D ARRI RE C T S DESSUS VENTS TABLETTE FA ADE ETC SONT RESPECT S LA LETTRE AVERTISSEMENT AVERT...

Страница 76: ...cran de protection et enfoncez sur de l appareil Attention ne pas rayer lacoul e de fond WARNING GLASS MAY BE HOT DO NOT TOUCH GLASS UNTIL COOLED 5 0 FINISHING 5 1 CAST FRONT INSTALLATION AND REMOVAL...

Страница 77: ...n cessaire de retirer la fa ade en fonte cependant cela facilitera l installation des b ches Pour installer les b ches la porte vitr e doit tre enlev e Voir la section INSTALLATION ET ENL VEMENT DE L...

Страница 78: ...the right end of log 2 D Reinstall the glass door front 5 6 LOGO PLACEMENT 5 5 1 SWITCH FUNCTIONS W415 1332 A 11 21 14 Retirez le papier dorsal et positionnez le logo sur la porte de commande tel qu...

Страница 79: ...ES POUSSETTES OU LES PARCS DE JEU CE SAC N EST PAS UN JOUET NOUEZ LE AVANT DE LE JETER A D branchez l alimentation lectrique de l appareil B Ouvrez la porte de contr le situ e au bas l avant de l appa...

Страница 80: ...rectangulaires et le fil de mise la terre Figure 7 H Alignez la soufflerie avec l arri re du bo tier de contr le et fixez la avec les deux vis fournies dans l ensemble Figure 8 I R installez le couve...

Страница 81: ...ILISATEUR VEILLEUSE LECTRONIQUE SOUPAPE LECTRONIQUE Cet appareil doit tre raccord lectriquement et mis la terre conform ment aux codes locaux En l absence de codes locaux utilisez la version courante...

Страница 82: ...tez les piles dans l metteur 11 Appuyez sur le bouton ON de la t l commande Vous devriez entendre un bip du r cepteur vous indiquant que la communication est bonne Pour activer le r cepteur r f rez vo...

Страница 83: ...le couvercle B Assurez vous que le commutateur glissi re est plac la position REMOTE position centrale C Appuyez sur le bouton r initialisation programmation utilisez un objet de petite taille comme...

Страница 84: ...ce 35 5A 73 F 23 C 8 3 AFFICHER DE TEMP RATURE 8 4 HAUTEUR DE LA FLAMME Si l appareil est muni d une soufflerie la vitesse de celle ci peut tre contr l e par le syst me de t l commande La soufflerie c...

Страница 85: ...t l commande 35 22 76 F IPI 76 F CPI 76 F IPI 76 F CPI 8 8 FONCTION DE S CURIT POUR ENFANTS Cette fonction verrouillera les touches pour emp cher une utilisation non supervis e A Appuyez simultan ment...

Страница 86: ...es du r cepteur sont faibles celui ci n mettra pas de bip lorsqu il recevra une commande MARCHE ARR T Ceci est pour vous signaler que les piles du r cepteur sont faibles Lorsque les piles sont remplac...

Страница 87: ...ser la plaque de restriction bloquant le chemin d chappement Ceci r duit la vitesse des gaz d chappement ralen tissant le mod le de flamme et cr ant un aspect de flamme plus traditionnel Pour les vent...

Страница 88: ...ge de la veilleuse ou remplacez le Une toile d meri ou un tampon r curage comme Scrotch Brite peut tre utilis pour enlever la peinture sur la hotte de la veilleuse sur l lectrode et sur le capteur de...

Страница 89: ...protection le nettoyage peut tre n cessaire en raison d un exc s de poussi re peluches des tapis animaux etc utilisez un l attachement du brosse sur aspirateur pour nettoyer l cran 6 Si votre appareil...

Страница 90: ...la veilleuse et aussi s il y a lieu sur la thermopile le thermocouple le capteur de flamme et l allumeur REMARQUE Vous devrez nettoyer le capteur de amme l aide d une morceau de de laine d acier ou un...

Страница 91: ...with the requirements of the provincial state authorities having jurisdiction and in accordance with the requirements of the CAN1 B149 Installation Code in Canada and theANSI Z223 1 National Fuel Gas...

Страница 92: ...SSEMENT 10 5 SOINS DES PI CES PLAQU ES 6 1 Si l appareil est muni de pi ces plaqu es vous devez enlever toutes traces de doigts ou autres marques des surfaces plaqu es avant d allumer l appareil pour...

Страница 93: ...50 0342 W430 0013 W080 1786 W655 0239 W660 0009 W135 0257 W010 3685 W010 2020 W135 0232 14 12 13 7 FA ADE EN FONTE L CRAN DE PROTECTION ASSEMBLAGE DE LA PORTE L ASSEMBLAGE DU COUVRE DE CONTR LE BO TIE...

Страница 94: ...UPAPE P 17 18 HARNAIS DE FILS PRO 2 W750 0276 W750 0412 HARNAIS DE FILS DE SOUFFLERIE LUMI RE HARNAIS DE FILS DU BO TIER DE PILES W750 0268 6 7 7 0 W660 0126 SER T L COMMANDE PRO 2 10 W432 0078 COLLEC...

Страница 95: ...CELAINE DU C T DROITE PRP25 7 8 GSB25KT SOUFFLERIE GDSLL KT TROUSSE POUR MISE DE NIVEAU FIXATION DE L APPAREIL 1 A stone inset can be cut to enhance the cast top and to match the room d cor A template...

Страница 96: ...la veilleuse et de la soupape sont bien mis la terre au niveau du ch ssis m tallique de l appareil ou de l ensemble de b ches tincelle la veilleuse mais celle ci ne s allume pas Alimentation en gaz V...

Страница 97: ...nnexions sont bien serr es V rifiez si tout le filage est install exactement tel que sp cifi Harnais de fils Inspectez le harnais de fils et v rifiez qu il soit solidement branch au module V rifiez qu...

Страница 98: ...limit e du Pr sident ne peuvent faire l objet que d une seule r clamation Durant les dix premi res ann es NAPOL ON remplacera ou r parera les pi ces d fectueuses qui sont couvertes par la garantie vi...

Страница 99: ...liers Travail effectu Nom du technicien D taillant Historique d entretien de l appareil Cet appareil doit tre entretenu annuellement selon son usage Date 15 0 HISTORIQUE D ENTRETIEN DE L APPAREIL FR W...

Страница 100: ...r al Qu bec H4T 1A3 24 Napoleon Road Barrie Ontario Canada L4M 0G8 214 Bayview Drive Barrie Ontario Canada L4N 4Y8 103 Miller Drive Crittenden Kentucky USA 41030 NAPOL ON C L BRE PLUS DE 40 ANS D EXIS...

Отзывы: