EN
W415-1968 / 06.26.19
5
standard checklist
Installer, please fi ll out the following information:
Customer:
Address:
Date of Installation:
Location of appliance:
Installer:
Dealer/Distributor contact number:
Serial #:
Model:
Natural Gas:
GVFS20-1N
Propane:
GVFS20-1P
1.0 general information
When the appliance is installed at elevations above 2,000ft, and in the absence of specifi c recommendations from the local
authority having jurisdiction, the certifi ed high altitude input rating shall be reduced at the rate of 4% for each additional
1,000ft. Expansion / contraction noises during heating up and cooling down cycles are normal and to be expected.
No external electricity (110 volts or 24volts) is required for the gas system operation.
This appliance is equipped with a pilot light safety system referred to as an oxygen depletion sensor and is designed to
turn off the appliance if not enough fresh air is available.
This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not
convertible for use with other gases, unless a certifi ed kit is used.
The protective wrap on plated parts is best removed when the assembly is at room temperature but this can be
improved if the assembly is warmed, using a hair dryer or similar heat source.
This appliance is a decorative product. It is not a source of heat and not intended to burn solid fuel.
A barrier designed to reduce the risk of burns from the hot viewing glass is provided with the
appliance and must be installed.
note:
1.1
rates and effi ciencies
For your satisfaction, this appliance has been test-fi red to assure its operation and quality!
GVFS20-1
NG
P
Altitude (FT)
0-2,000
0-2,000
Max. Input (BTU/HR)
23,000
23,000
Min. Inlet Gas Supply Pressure
4.5" Water Column
11" Water Column
Max. Inlet Gas Supply Pressure
7" Water Column
13" Water Column
Manifold Pressure (Under Flow Conditions)
3.5" Water Column
10" Water Column