![Napoleon Acies L38N Скачать руководство пользователя страница 88](http://html1.mh-extra.com/html/napoleon/acies-l38n/acies-l38n_installation-manual_3296277088.webp)
W415-1707 / 07.04.17
88
FR
exigences d'évacuation
10’
10’
15’
15’
20’
20’
30’
40’
5’
5’
1-3 elbow zone
H
V
V
1
V
2
H
2
H
1
V
=
V
1
+
V
2
= 8 ft
H
=
H
1
+
H
2
= 10 ft
90°
90°
V
1
V
2
H
1
H
2
V and H are measured from the center of the vent elbows
This example represents a vent that has a maximum of three 90º elbows, a combined horizontal vent length (H ) of
10 feet and a combined vertical vent length (V) of 8 feet.
0’
0’
Base of
air collar
Base of
air collar
Since the vent is located in the dark shaded area, it is within the acceptable vent configuration
1-3 Zone de coude
Base du
collier
d'air
Base du
collier
d'air
V et H sont mesurés à partir du centre des coudes de ventilation.
Cet exemple représente un évent qui a un maximum de trois coudes, une longueur de ventilation horizontale
combinée (H) de 10 pieds et une longueur d’évent verticale (V) combinée de 8 pieds
Étant donné que l’évent est situé dans la zone sombre sombre, il se trouve dans la configuration d’évent
acceptable.