SYSTEM OPTIONS (ADDRESS 2423)
SYSTEM OPTION:
1. Select the System Option from the table shown and enter in the corresponding address location at right.
Keypad Blank-
ing
will clear all data from the LCD display (and turn off all keypad LED's) after the system is armed and delay time has ex-
pired. The display will re-appear when an exit/entry door is faulted, causing an entry time delay display, or if a valid user code
is entered at the keypad while the system is armed.
2. Press
U
or
D
to save.
NOTE:
Dark shaded data value box shows option not available.
ADDRESS 2423
SYSTEM OPTIONS
DATA ENTRIES
RIGHT
OPTION
1
Enable ACM Access
2
RESERVED
3
Enable TCP/IP Communications
4
TCP/IP Panel/Site Initiated Functions
5
RESERVED
6
RESERVED
7
RESERVED
8
Enable Keypad Blanking
EMERGENCY FREE ACCESS (ADDRESS 4080)
ENABLE ACM OPTION:
1. Select the Emergency Free Access
Zone Number (1-255) and enter corre-
sponding address location at right.
2. Press
U
or
D
to save.
ADDRESS 4080
[Default = 000]
Emergency
Free Access
Zone Number
AC
M
O
P
T
IO
N
S