5
K E Y P A D C O N T R O L S & I N D I C A T O R S
1. Window.
Lights indicate system
status messages; digit display
indicates related zone, function or
error message numbers.
Note:
"Lb" ("low battery") appears when key-
pad battery must be replaced (see
Troubleshooting on page 24)
2. Dot.
Hub/keypad wireless connection
status. Off when transmitting data, lit
after receiving Hub transmissions. Will
turn off after Hub AC power is removed.
3. Chime.
Indicates the door chime
option is enabled (turned on).
4. MENU Button.
Selects available
system functions as displayed in the
Window. The selected function is
executed by pressing
ENTER
.
5. BYPASS
Button.
(1) Deactivates
selected zones in the system. (2)
Unbypasses a bypassed zone.
6. RESET
Button.
(1) Resets various
system troubles, displays, etc. (see
text) (2) Resets the ISEC-SMOKE
smoke detector(s) in the system.
7. Numerical Keys (1-9, 0).
Used to
enter codes, zone numbers, etc.
8. Emergency
Buttons.
Used with the
AREA ( ) button to signal an audible
emergency, as follows:
Press the
7
and the
buttons for
Fire
Emergency.
Press the
8
and the
buttons for
Auxiliary
Emergency.
Press the
9
and the
buttons for
Police
Emergency.
9. AREA
Button
(
). Selects other
Areas and is used with Emergency
Buttons (described above).
10. AWAY Button.
(1) Arms all zones in
the system. (2) Scrolls Window
display backward. (3) Answers "NO" to
questions in the Window display.
11. STAY Button.
(1) Bypasses all Interi-
or Zones simultaneously ("STAY
Mode") to allow free movement within
the premises. Hold down
STAY
when
the system is armed in "STAY Mode"
to cancel entry delay on Exit/Entry
zones, to cause an instant alarm upon
violation. (2) Scrolls the Window
display forward. (3) Answers "YES" to
questions in the Window display.
12. ENTER Button.
Entry key. Causes
the entered code or selected function
to be executed.
13. Room Light Sensor.
Measures am-
bient light level to determine if Window
backlight should be turned on after a
keypad button press. See
Keypad
Windows Backlight
on page 18.
14. System Status Messages.
Messag-
es appear in the Window display when
active. Includes FIRE, TROUBLE,
ARMED, INSTANT, STAY, BYPASS,
CANCL'D, AWAY and READY.
For example, when the system is
ready to be armed, the word "READY"
appears, and will not appear if a zone
is not secured (the unsecured zone
number will also display in the Win-
dow). If a zone has been bypassed,
the word BYPASS will always appear
(while disarmed or armed). The word
ARMED will appear to indicate that the
system is armed. If an alarm has
occurred, the word ARMED will be
flashing.