NAPCO Security Systems
GEM-P816 Installation Instructions
WI994A 10/99
Page 19
Compatibility Number (Not Applicable)
THIS FEATURE IS NOT COMPATIBLE WITH THE GEM-P816 CONTROL
PANEL.
Press the
button to continue or press the
button to exit.
EZM Address
The keypad's internal EZM (Expansion Zone Module) may be utilized to
provide four additional wired zones. Whether used alone or in conjunction
with optional GEM-EZM series modules or other keypad EZMs, it must be
assigned a unique address (or Group number, see Keypad Programming
Workbook) similar to its keypad address. If no other EZMs are to be used, designate the keypad as Group “01” at the “
” display. In multiple-EZM systems, enter an assigned group number “01” through “02”. (Each EZM must
have a unique assigned group number, starting with “01” and proceeding consecutively.) Press the
button to
continue or press the
button to exit.
Zone Response
The normal loop response of each keypad expansion zone is 750mS,
however the response time of any zone can be reduced to 50mS as follows.
1. Of the following, circle the number(s) in parentheses associated with the
zone(s) to be changed:
Zone 1=(1); Zone 2=(2); Zone 3=(4); Zone 4=(8)
2. Add up the circled numbers.
3. At the keypad, enter the sum as a two-digit number “01” through “15” on the display, then press the
button.
Example.
Change Zones 2, 3 and 4 to 50mS response.
1. Circle numbers for Zones 2, 3 and 4: (2), (4) and (8).
2. Add up the circled numbers: 2 + 4 + 8 = 14.
3. Enter “14” at the keypad, then press the
button.
Press the
button to continue or press the
button to exit.
Program Control Message (Not Applicable)
THIS FEATURE IS NOT COMPATIBLE WITH THE GEM-P816 CONTROL
PANEL.
Press the
button to continue (the display will loop back through selections, for changes) or press the
button
to exit the Keypad Configuration Mode (display will read “
”). Then replace Jumper JP1 across Pins 1–2
(top two).
Key
p
ad Confi
gur
ati
on M