KEYPAD MESSAGES 

The GEM-RP8-LCD Keypad can display the following messages.  

Note:

 Refer to OI276. 

ALARM - Alarm condition, followed by one or more zone descriptions. 

ALARM MEMORY - Appears after an alarm condition and a valid code is en-

tered or when alarm condition times out.  Warns of a past alarm 
condition. 

BELL TEST - Appears after entering this Function Menu item that initiates bell 

test.  Enter this command to turn on the Bell, keypad sounder and 
keypad LEDs for 2 seconds. 

BYPASSED ZONES - Displays one or more zones bypassed. 

CAN'T ARM SYSTEM - Arming attempt made, but system condition prevents 

arming. 

CAN'T ARM SYSTEM...PRESS RESET - Displays when arming is attempted 

with the Fire icon on or system troubles displaying.  Solution is to 
press the RESET button and then arm the system. 

CAN'T ARM SYSTEM...SILENCING - Displays when the bell is on and a valid 

code is entered. 

CAN'T ARM SYSTEM...ZONE FAULTED - Displays when arming is at-

tempted with a Zone in trouble.  Secure zone (or bypass) before 
arming. 

DEALER PROGRAM MODE - Appears after entering a valid Dealer Code and 

entering Dealer Program Mode. 

DIRECTORY - Displays a list of all zone descriptions. 

DISARM NOW XXX SECONDS - Entry delay in progress.  XXX = Entry time 

remaining in 2-second decrements. 

ENTER CODE FOR  PROGRAM MODE - Appears after Function Menu item 

is selected to Activate Program Mode.  Enter your code then press 
ENTER to enter Program Mode. 

ENTER CODE FOR USER x - Enter the number of the user to be added or 

changed, enter the 4 digit code. 

ENTER DEALER CODE TO EXIT - In Dealer Program Mode, appears after 

pressing [Function] [8].  You must enter the Dealer code to leave 
Dealer Program Mode. 

ENTER LOCATION  <   > - In Dealer Program Mode, enter a 2-digit location 

number (see programming sheet).   

FAULTED ZONES - One or more zones not secured.  Status of zone descrip-

tion(s) displayed. 

FIRE ALARM - Alarm condition on a Fire Zone.  Enter your code then press 

ENTER to silence the sounder.   

FORCED RESET - Appears when pressing [1] [2] and [3] simultaneously. 

INVALID ENTRY TRY AGAIN - Wrong code entered. 

LCD TO LCD TRANSFER OPTION - Zone descriptions and other keypad 

configuration information can be transferred from the programmed 
keypad (Sending) to the unprogrammed others (Receiving) in the 
system. 

NONE - May appear if message "ZONE FAULTED" displays--but the zone 

clears after entering the Function Menu. 

OUT OF SYSTEM - Appears about 30 seconds after disconnecting (or short-

ing to ground) the green data wire.  Also appears after disconnecting 
the data wire and pressing RESET.  This message must display in 
order to access Keypad Configuration Mode. 

PLEASE EXIT XXX SECONDS - Displays exit delay time in 2-second decre-

ments. 

READY TO ARM - All zones operating; system can be armed.  ("SYSTEM 

READY" is an alternate equivalent message). 

RECEIVING - Appears while receiving Keypad Configuration or Zone Descrip-

tions from a Quickloader or another RP8LCD keypad that is sending 
data. 

RP CONFIGURATION MODE - You are entering the RP8LCD Configuration 

mode.  Changes in this mode are stored in the keypad. 

RP VERSION - Software version appears when entering Keypad Configura-

tion Mode. 

SENDING - Appears while sending Zone Descriptions to another RP8LCD  

SENDING STOPPED - PLEASE WAIT - When large amounts of data are 

transferred, pauses may appear for a few seconds, accompanied by 
this message. 

SYSTEM ARMED - Panel armed. 

SYSTEM READY - All zones operating; system can be armed.  ("READY TO 

ARM" is an alternate equivalent message). 

-->TO START PRESS THE ENTER KEY - Initiate the LCD to LCD Transfer 

Option by pressing Enter on the keypad. 

USER PROG. MODE USERS  =   12345678 - Enter the number of the user to 

be added or changed and enter the 4-digit code. 

ZN DESCRIPTIONS MODE - You are entering the Zone Descriptions Mode 

which allows you to change and update the zone descriptions which 
appear on the keypad display to suit the particular design of the 
protected premises 

ZONE FAULTED - One or more zones not secured. 

 

 

System Troubles 

AC Failure - Power failure.  Check power transformer.  Check for blown fuse 

or circuit breaker; general power outage. 

Bell Wire Cut - Bell wire severed (open on bell circuit). 

Fail to Comm - Unsuccessful communication to central station.  Note: Will 

also display if panel is improperly programmed to report:  i.e., Re-
port Alarm, Report Codes, Subscriber ID Numbers, etc.  Must be 
programmed. 

Telco Line Cut - Telephone line cut or system down. 

Low Battery - Battery below 11 volts.  If not recharged within 48 hours after 

AC is restored, replace battery. 

Rcvr or Ezm Tbl - EZM module cover removed, or keypad EZM not respond-

ing, or receiver not responding. 

RF Receiver Jam - Receiver not responding/jammed. 

RF LB / ZnXX - Burglar Transmitter Low Battery.  XX = The zone number to 

which the transmitter is mapped.  Replace Battery.   

RF SUP ZnXX - Supervisory Burglar Transmitter Indication--panel has not 

received a signal from the transmitter within 12 (default) hours or 
programmed time.  XX = The Zone number to which the transmitter 
is mapped.  Replace Battery.   

RF Smk LB #XX - Smoke Detector Low Battery.  XX = The smoke detector 

number as programmed in the panel.  Replace Battery.   

RF Smk SUP #XX - Supervisory Smoke Detector Indication.  Panel has not 

received a response from the transmitter within 4 (default) hours or 
programmed time.  XX = The smoke detector number as pro-
grammed in the panel.  Replace Battery.   

Fire Trouble - Appears when an open in the hard-wired smoke detector exists. 

Zn Trouble #XX - Appears when a zone trouble exists.  The panel has one or 

more of the following 3 troubles:  Zone Short (P800 panels only), 
Transmitter Tamper or Dual Tech Self Test Fail.  XX = The Zone 
number. 

Содержание GEM-RP8LCD

Страница 1: ...l GEM RP8LCD keypad and the GEM RP8 may be intermixed but require different configuration procedures as described in the following paragraphs For an overview of the GEM RP8LCD programming modes see th...

Страница 2: ...re F is programmed pressing 7 and G will activate fire panic These features must also be enabled in panel pro gramming via Dealer Mode Press Uto save your selection U L Installa tions If Keypad Fire 2...

Страница 3: ...ted for longer than 4 minutes Entering a new zone description Use R and B to scroll to the desired zone Use 1 and 2 to position the cursor within the display Use 3 and 6 to scroll through numbers lett...

Страница 4: ...ad when a Chime Zone is violated The duration of the tone is panel programmable except for the P800 To deactivate the Chime Mode re enter the Function Menu and when DEACTIVATE CHIME is displayed press...

Страница 5: ...2 3 The keypad will beep four times confirming a valid entry They keypad will automatically save the new User Code for the user number and reset to allow a new user number to be programmed or reprogra...

Страница 6: ...perating system can be armed SYSTEM READY is an alternate equivalent message RECEIVING Appears while receiving Keypad Configuration or Zone Descrip tions from a Quickloader or another RP8LCD keypad th...

Страница 7: ...re from Remote Bus Panel terminal Press C OUT OF SYSTEM Software RP version number appears KEYPAD PROGRAMMING MODES FUNCTION MENU PROGRAM MODE KEYPAD MESSAGE CONDITION DISPLAY ZN FAULTED If Zone Fault...

Страница 8: ...rson purporting to act on its behalf to modify to change or to assume for it any other warranty or liability concerning its products In no event shall NAPCO be liable for an amount in excess of NAPCO...

Отзывы: