4. Wire zone device to the keypad Blue and Gray wires. 

 

EZM Zone 50ms Response (Default = 0) 

The default loop response of each keypad expansion zone is 750mS, 
however the response time of any zone can be reduced to 50mS as 
follows: 

To reduce zone 1 to 50mS, enter 1 on the display and press 

U

To reduce zone 2 to 50mS, enter 2 on the display and press 

U

To reduce both zone 1 and 2 to 50mS, enter 3 and press 

U

.

 

Access Control Message (Default = 0) 

The default Access-Control message is “

**ENTER NOW**

”.  This 

display may be changed to any of the following messages: 

 

ENTRY

                        

MESSAGE

 

0

                   

** ENTER NOW **

” (Default)

 

1

                   

Door Control

 

2

                   

Gate Control

 

3

                   

Light Control

 

Enter the number of the message you wish displayed and press 

U

.   

 

Exit Delay Time Display (Default = 045) 

The delay time which permits exit through an 

Exit/Entry Zone 

after the 

system is armed, allows a user to leave the premises without setting 
off an immediate alarm.  

Exit Delay 

may be programmed for up to 255 

seconds (4¼ minutes).  Enter the number of seconds and press 

U

.  

Note:  

Changing this configuration updates the 

keypad only, 

not the 

panel.  The panel delay time is updated via Dealer Mode only; to keep 
the panel and keypad delay times synchronized, be certain to program 
the keypad for the same time as programmed for the panel. 

 

Entry Delay Time Display (Default = 030) 

Entry delay time permits entry through 

Exit/Entry Zone(s) 

after the 

system is armed without setting off an immediate alarm.  

Entry Delay

 

allows the user time to enter and disarm the system.  Upon entering, 
the keypad sounder will sound an entry sound to remind the user to 
disarm the system.  

Entry Delay

 

Time

 may be programmed for up to 

255 seconds (4¼ minutes).  Enter the number of seconds and press 

U

.  

Note:  

Changing this configuration updates the 

keypad only, 

not 

the panel.  The panel delay time is updated via Dealer Mode only; be 
certain to program the keypad for the same time as programmed for 
the panel. 

 

Exiting Keypad Configuration Mode 

Press 

R

 to loop back through selections or press 

C

 to enter 

the Zone Descriptions Mode, in which you can change the zone de-
scriptions that appear on the keypad display.  If you wish to exit the 
Keypad Configuration Mode, press 

C

 (display will read “

OUT OF 

SYSTEM

”).  Replace the green wire to the Remote Bus Panel Terminal.  

Display will display panel status. 

 
 

ZONE DESCRIPTIONS MODE 

Zones are independent circuits that protect specific areas of the 
premises.  The displayed zone descriptions may be changed to suit the 
particular design of the premises.  To change Zone Descriptions: 
1.     Disconnect green wire from Remote Bus panel terminal. 
2.     Press 

C

 and the display reads “

OUT OF SYSTEM

”. 

3.     Enter factory code:  11123 

R

The software version number appears briefly, then “

RP CONFIGURA-

TION MODE

” appears.  After a few seconds, the words “

Feedback 

Beep Presently ON

” appear.   

 

4.     Press 

C

 and “

ZN DESCRIPTIONS MODE

” displays. 

Scroll descriptions forward or backward using 

R

 and 

B

, respectively. 

To return to normal keypad operation, press 

C

 and reconnect the green 

wire to the Remote Bus panel terminal. 

After entering Zone Descriptions Mode, the keypad will automatically return 
to “

OUT OF SYSTEM

” if no activity is detected for longer than 4 minutes. 

 

 
 

 
 

 

Entering a new zone description 

Use 

R

 and 

B

 to scroll to the desired zone. 

Use 

1

 and 

2

 to position the cursor within the display. 

Use 

3

 and 

6

 to scroll through numbers, letters, etc. 

Use 

4

 and 

5

 to erase text while moving the cursor back-

wards and forwards. 

With the cursor located under a word, use button 

7

 to move the 

entire word to the left, and use 

8

 to move the word to the right.   

Press 

U

 to save when the zone description is complete. 

 

Quick Word List 

The keypad contains pre-programmed zone descriptions, avoiding the 
need to scroll through individual numbers, letters, and symbols.  Press 

G

 followed by the two-digit number of the entry listed in the Quick 

Word List table (above).  For example, to enter the description “DINING 
ROOM”, press 

G

 

1 9

 

G

 6 1.  

Note:  

A space is automatically set 

after Quick Words are entered, and entering 

G

 

0

 

0

 splits an 

existing word. 

 
 

LCD TO LCD TRANSFER OPTION 

 

Zone descriptions can be transferred from the programmed keypad 
(master) to the unprogrammed others (slaves) in the system.   

 

1.      Program the primary keypad (master) with the appropriate zone 

descriptions, etc, as described in Zone Descriptions Mode above. 

2.      As a safety precaution, remove AC and DC power to the panel. 
3.      Wire all keypads to the panel and reapply power. 

 

The LCD TO LCD TRANSFER OPTION is accessed through Keypad 
Configuration Mode, as follows: 

 

4.      Disconnect green wire from Remote Bus panel terminal. 
5.      Press 

C

 and the display will read “

OUT OF SYSTEM

”. 

6.      Enter the factory code of 11123 

R

The software version number appears briefly, then the words “

RP 

CONFIGURATION MODE

” appear.  After a few seconds, the words 

Feedback Beep Presently ON

” appear.   

 

7.      Press 

C

 and 

P

 and “

LCD TO LCD TRANSFER OPTION

” will 

display.  The keypad is now ready to replicate keypad data to the 
other keypads in the system.   

8.      In order for the transfer to take place, all keypads must be physically 

linked to each other and isolated from the panel.  Therefore, connect all 
green wires from all keypads.  Do not connect green wires to panel. 

9.      To  initiate  the  transfer,  press 

U

.  The master keypad will start 

transmitting data to all slaves.  The words 

SENDING 

are displayed 

as the keypad cycles through the database (which is displayed on 
the LCD during this process).  At short intervals, the words 

SENDING STOPPED…PLEASE WAIT

” will display.  Similarly, the slave 

keypads receiving data will display” 

RECEIVING

”. 

10.    When complete, the words “

OUT OF SYSTEM

” will display.  Re-

connect all wires as described previously for normal operation. 

01=ACCOUNTING 
02=ALARM 
03=APARTMENT 
04=AREA 
05=ATTIC 
06=BABYS 
07=BACK 
08=BASEMENT 
09=BATH 
10=BEDROOM 
11=BOYS 
12=CEILING 
13=CLOSET 
14=COMPUTER 
15=CONTROL 
16=DEN 
17=DEPARTMENT 
18=DETECTOR 
19=DINING 
20=DOOR 
21=DOWN 

22=DOWNSTAIRS 
23=EAST 
24=ENTRY 
25=EXERCISE 
26=EXIT 
27=FAMILY ROOM 
28=FIRE 
29=FIRST 
30=FLOOD 
31=FLOOR 
32=FOIL 
33=FOYER 
34=FRENCH 
35=FRONT 
36=GARAGE 
37=GATE 
38=GIRLS 
39=GLASS 
40=GREAT 
41=GUEST 
42=HALL 

43=INTERIOR 
44=KITCHEN 
45=LAUNDRY 
46=LEFT 
47=LIVING 
48=LOBBY 
49=LOW 
50=MAIDS 
51=MASTER 
52=MOTION 
53=NORTH 
54=OFFICE 
55=PHONE 
56=PLAY 
57=PORCH 
58=PROTECTION 
59=REAR 
60=RIGHT 
61=ROOM 
62=SAFE 
63=SALES 

64=SHED 
65=SHIPPING 
66=SIDE 
67=SKYLIGHT 
68=SLIDING 
69=SMOKE 
70=SOUTH 
71=SPACE 
72=STAIRS 
73=STUDY 
74=TAMPER 
75=TEMPERATURE 
76=UPSTAIRS 
77=UTILITY 
78=WAREHOUSE 
79=WEST 
80=WINDOW 
81=WORKSHOP 
82=UP 

Quick Word List

 

Содержание GEM-RP8LCD

Страница 1: ...l GEM RP8LCD keypad and the GEM RP8 may be intermixed but require different configuration procedures as described in the following paragraphs For an overview of the GEM RP8LCD programming modes see th...

Страница 2: ...re F is programmed pressing 7 and G will activate fire panic These features must also be enabled in panel pro gramming via Dealer Mode Press Uto save your selection U L Installa tions If Keypad Fire 2...

Страница 3: ...ted for longer than 4 minutes Entering a new zone description Use R and B to scroll to the desired zone Use 1 and 2 to position the cursor within the display Use 3 and 6 to scroll through numbers lett...

Страница 4: ...ad when a Chime Zone is violated The duration of the tone is panel programmable except for the P800 To deactivate the Chime Mode re enter the Function Menu and when DEACTIVATE CHIME is displayed press...

Страница 5: ...2 3 The keypad will beep four times confirming a valid entry They keypad will automatically save the new User Code for the user number and reset to allow a new user number to be programmed or reprogra...

Страница 6: ...perating system can be armed SYSTEM READY is an alternate equivalent message RECEIVING Appears while receiving Keypad Configuration or Zone Descrip tions from a Quickloader or another RP8LCD keypad th...

Страница 7: ...re from Remote Bus Panel terminal Press C OUT OF SYSTEM Software RP version number appears KEYPAD PROGRAMMING MODES FUNCTION MENU PROGRAM MODE KEYPAD MESSAGE CONDITION DISPLAY ZN FAULTED If Zone Fault...

Страница 8: ...rson purporting to act on its behalf to modify to change or to assume for it any other warranty or liability concerning its products In no event shall NAPCO be liable for an amount in excess of NAPCO...

Отзывы: