background image

 
Emergency Buttons  
 

 

 
The three sets of emergency buttons, if programmed, are always active whether the system is armed 
or disarmed.  Discuss these Buttons with your installer.  The emergency signal will only be activated 
when the two respective buttons are pressed at the same time. 

 
 

Fire Alarm:  

Simultaneously press 

E

+

E

 to sound a fire alarm, and to alert the central station of a 

fire emergency, if so programmed. 

 

 

Auxiliary Alarm:  

Simultaneously press 

F

+

F

 to alert the central station of an auxiliary emergency, 

if so programmed.  (The nature of this emergency alarm is to be determined by the installer) 

 

 

Police Emergency:

 Simultaneously press 

G

+

G

 to sound a police emergency alarm, and to alert 

the central station of a fire emergency, if so programmed.   

Emergency Conditions 

E F G 
E F G 

E

  

Fire  

e

  

Emergency

 

    

Enabled? 

       

 

 

Yes    

F

     Auxiliary  

F

      Emergency 

    

Enabled? 

    

 

Yes    

Ambush Alarm

  

 

In the event that you are forced by an intruder to disarm your system, the "ambush alarm" can be acti-
vated.  Disarming the system with the Ambush Code will cause the system to appear to disarm nor-
mally--however, a silent ambush alarm signal will be sent to the Central Station.  If your system has 
the Ambush feature enabled, the code assigned as the User 6 code will function as your Ambush 
Code. 

G

  

Police  

G

  

Emergency

 

    

Enabled? 

    

    
Yes                                    

    

Ambush  

                 Alarm

 

                 Enabled? 

    

    
Yes                                    

Содержание EXPRESS XP-600

Страница 1: ...1 Using Your XP 600 Security System NAPCO NAPCO 2006 OI301B 4 06...

Страница 2: ...door and it is open the zone 1 light will be on If zone 2 is a motion detector and there is movement in that area zone light 2 will turn ON Depending upon the actual layout your security professional...

Страница 3: ...ssary 15 1 Bell Battery Test Test your bell or siren by pressing G followed by 1 This will cause the bell or siren to sound for 2 seconds and also initiate a test of the battery 2 Central Station Comm...

Страница 4: ...ate that the corresponding Zone is open and will flash to indicate a zone in alarm X Ready Light will light when all zones are se cure and system is ready to be Armed Key Reset used to clear miss ente...

Страница 5: ...to disarm system and then re enter code and leave Easy Arm The Easy Arm feature allows the system to be armed by simply pressing A followed by 0 This will allow the easy arming of the system by someon...

Страница 6: ...typically done in the evening when all family members are home for the night Instant Mode can be activated at any time after the system has been armed The Red W Armed light will flash rapidly while in...

Страница 7: ...arm is to be determined by the installer Police Emergency Simultaneously press G G to sound a police emergency alarm and to alert the central station of a fire emergency if so programmed Emergency Con...

Страница 8: ...until B is pressed to reset the alarm memory Silencing a Fire Alarm In the event that the Fire alarm activates due to an violated smoke or fire detector the bell or siren will sound a distinct pulsat...

Страница 9: ...ad Carefully Discuss each of these escape procedures with all those who use the building 1 In a residence sleep with the bedroom door closed 2 When the fire alarm signals escape quickly Do not stop to...

Страница 10: ...10 Fire Protection Floor Plan Draw a plan of your premises below...

Страница 11: ...grammed pressing A followed by 3 will activate the Access Output which may be configured to open a door strike turn on lighting or activate some other special feature your installer has provided A 4 I...

Страница 12: ...es Zone light ON System Trouble Condition Action 1 Beep with Y flashes 1 AC Power Failure This trouble will occur if AC power is not present Make sure system transformer is plugged into AC receptacle...

Страница 13: ...s C Cell Duracell MN1400 batteries 4 Warning Replace batteries only with the same type as specified above Use of another battery may present a risk of fire or explosion Do not recharge or disassemble...

Страница 14: ...he User 2 code The keypad will beep 2 times and the corresponding zone light will flash to indicate the user number you are about to program 2 Press in the 4 digits of the new User 2 code the keypad w...

Страница 15: ...en opened while the system is disarmed Easy Exit Allows an occupant to leave the premises without disarming the sys tem Pressing A and then 0 while the system is armed will permit exit by removing the...

Страница 16: ...d and insured to NAPCO After repair or replacement NAPCO assumes the cost of returning prod ucts under warranty NAPCO shall have no obligation under this warranty or otherwise if the product has been...

Отзывы: