![NAPCO EXPRESS XP-600 Скачать руководство пользователя страница 5](http://html2.mh-extra.com/html/napco/express-xp-600/express-xp-600_programming-instructions-manual_3291843005.webp)
5
Zn 1 LED ON = Momentary Keyswitch Arming
6\VWHP 7LPHV
Entry Delay, seconds
(0)
(3)
(0)
Maximum Entry 255
11
Entry Delay
Exit Delay, seconds
(0)
(4)
(5)
Maximum Entry 255
10
Exit Delay
Bell Time-out, minutes
(0)
(0)
(5)
Maximum Entry 255
12
Burg (Steady) Output Time-out
Bell Time-out, minutes
(0)
(0)
(0)
Maximum Entry 255
13
Fire (Pulsed) Output Time-out
Test Timer, days
(0)
(0)
(1)
Maximum Entry 255
14
Test Timer Interval
Line Cut Time-to-Fail, seconds
(0)
(0)
(0)
Enable Feature-Valid Entries 10-255
15
Line Cut Time-to-Fail (Disabled = 000)
Supervisory Timer, hours
(1)
(2)
Maximum Entry 26
16
Wireless Supervisory Timer
Smoke Supervisory Timer, hours
(8)
Maximum Entry 8
17
Wireless Smoke Supervisory Timer
Test Timer Offset, hours
(1)
(2)
Maximum Entry 23
18
Test Timer Offset
6\VWHP )HDWXUHV
UL
Includes Bell Cut, Fire Trouble, Receiver Fail-to-Respond, Receiver Tamper,
Receiver JAM, Transmitter Low Battery, Transmitter Supervisory Faliure,
Wireless Smoke Low Battery and Wireless Smoke Supervisory Failure.
N
OTE
3:
Cannot be programmed with any other Programmable Output (PGM) Feature.
N
OTE
2:
Default
OFF
OFF
OFF
OFF
23
Programmable Output (PGM) Features 1
Zn 1 LED ON = Audio Verification
Zn 2 LED ON = *Access Output (
)
Zn 3 LED ON = *Follow Keypad Sounder
Zn 4 LED ON =
*Keyfob/Keyswitch Chirp
*See Note 2
Default
OFF
OFF
OFF
OFF
24
Programmable Output (PGM) Features 2
Zn 1 LED ON = Fire
Zn 2 LED ON = AUX
Zn 3 LED ON = Panic
Zn 4 LED ON = Test Timer
Default
OFF
OFF
OFF
OFF
26
Miscellaneous Features 2
Zn 2 LED ON = Reserved
Zn 3 LED ON = Inhibit Fail to Communicate
Zn 4 LED ON = Inhibit Low Battery Display
UL
Default
OFF
OFF
OFF
OFF
25
Programmable Output (PGM) Features 3
Zn 1 LED ON = AC Fail
Zn 2 LED ON = Low Battery
Zn 3 LED ON = *Trouble
Zn 4 LED ON = Armed
*See Note 3
Default
OFF
OFF
OFF
ON
20
Keypad Features 1
Zn 1 LED ON = *Keypad Fire (
)
Zn 2 LED ON = *Keypad AUX (
)
Zn 3 LED ON =
*Keypad Panic (
)
*See Note 1
Default
OFF
OFF
ON
ON
21
Keypad Features 2
Zn 1 LED ON = Audible panic
Zn 2 LED ON = Exit/Entry with Urgency
Zn 3 LED ON =
Display Bypass (ARMED)
Zn 4 LED ON = Disable Code Entry Beeps
Default
ON
OFF
OFF
ON
22
Miscellaneous Features 1
Zn 1 LED ON = Abort Delay
Zn 2 LED ON = Easy Arm/Easy Exit
Zn 3 LED ON = Swinger Shutdown
Zn 4 LED ON = Bell on Line Cut (Armed)
Additional programming required for reporting, see Blocks [36]&[56].
UL Installations: If Keypad Fire [20-1] is enabled, the keypad must be mounted
within (3) three feet from the Control Panel.
N
OTE
1:
Zn 4 LED ON = *Ambush (6th User Code)
UL
Wi847c
page 5
Tuesday, September 16, 1997 08:35