NAPCO EXPRESS XP-600 Скачать руководство пользователя страница 12

12

 -4     +5    +6

XP-600 Terminals

 

1        2      +3

GEM-RECV-XP8

16 VAC 20 VA
TRANSFORMER
NAPCO TRF12
(OR EQUIVALENT
SEE WI850A).
Class 2
Transformer.
DO NOT
connect to
switched
outlet.

 RED

+

 BLACK

E1

E2

RECHARGEABLE

BATTERY

12 VDC 4AH OR 7AH

This equipment should be installed in accordance with Chapter 2
of the National Fire Alarm Code, ANSI/NFPA 72-1993 (National
Fire Protection Association Batterymarch Park, Quincy MA
02269). and local codes.  Information describing proper installa-
tion, operation, testing, maintenance, evacuation planning, and
repair service is to be provided with this equipment.  UL Listed
Energy Cable is required.

ALL OUTPUTS  ARE CURRENT LIMITED

WARNING

TO PREVENT RISK

OF ELECTRIC SHOCK

DISCONNECT TELEPHONE

LINES PRIOR TO SERVICING

EARTH

GROUND

FIRE

BELL

P

rogr
am

m

abl
e

Ou
tp

u

t

PGM

(-)

12

+PWR

+10   -11   +12 -13     14    15

  16     17    18    19

 -7    +8      -9

 GND

+PWR

 GND GREEN

 TIP

 RING

 TIP

RING

PHONE

(Supervised)

To RJ31X

2.2K EOLR

2.2K EOLR

(SUPERVISED)

(E)

+

+

+

+

COLD WATER GROUND
CONNECTION
USE ONLY COLD-WATER
PIPE OR BURIED GROUND
ROD.  USE AT LEAST #16
AWG WIRE.

TELCO

RE
D

GR

N

GR

A

Y

BR
N

FIRE
PWR

/2

A

'

P$
0$;

REMOTE BUS

ZONE 3

(E)

.

(E)

.

ZONE 6

ZONE 5

(Z)

ZONE 1

(E)

.

ZONE 4

(Z)

(E)

5('

%/.

*51

Fire Loop
      In

4-Wire Fire Wiring

Power
Out (+)
Power
Out (-)

Power
In (-)

Fire Loop
    Out

RED

BLACK

BROWN

BROWN

FT2200

8

7

8

9

Power
In (+)

Fire Power

Ground

Fire Power

Fire

.

.

Normally Open Zone Wiring

Wire the normally open contact
as shown (Zone 4). Program
the zone for 

Open Circuit [06]

operation.

ZONE 2

.

(Z)

ZONE 1

(E)

.

ZONE 4

A

U

X

 P
O

W
E

R O

U

T

P

UT
 10-

12.
5 V

D

C

(1) 

ALL ZONE RESISTORS MUST BE INSTALLED,
EVEN IF ZONE IS NOT USED.

(2) 

COMBINED STANDBY = KEYPAD C
AUX POWER C FIRE POWER + PGM
CURRENT.

(3) 

24 HOUR STANDBY REQUIRES A  7AH BAT-
TERY.

XP-600 WIRING DIAGRAM

  (REFER TO INSTALLATION INSTRUCTIONS WI47C)

RESIDENTIAL BURG (4 HOUR STANDBY)

COMBINED STANDBY = 500 mA        BELL = 2.0 AMP

RESIDENTIAL FIRE (4 HOUR STANDBY) 

(2)

COMBINED STANDBY = 500 mA      BELL = 65 mA

RESIDENTIAL FIRE (24 HOUR STANDBY) 

(3)

COMBINED STANDBY = 120 mA      BELL = 95 mA

(1)

(Z)

.

.

.

RPX-6

GOLD

RED RED

RED

2.2K

(E)

(Z)

*2/'

:+,7( 5('

3.9K

25$1*(

EZ

Zone
Doubling

TM

Resistors

Wi847c 
page 12

Tuesday, September 16, 1997 08:35 

Содержание EXPRESS XP-600

Страница 1: ...all original wiring for ter minal 15 PGM and terminal 3 Note Any programming in Dealer Options 1 96 and Dealer Options 2 97 will not be de faulted If Dealer Code Lockout has been programmed the panel...

Страница 2: ...adecimal data entry Program Telephone Prefix Number with a 9E 1 Press Beep Beep 2 Press 3 Press 4 Press 2 Direct Entry Programming Block Enter data directly For hexadecimal entries of A F use the key...

Страница 3: ...rs Phone Numbers Pager Leading and Trailing digits and Report Codes NOTE Example Viewing the Dialing Prefix A Dialing Prefix of 9E has been programmed at Programming Block Num ber 44 outside access nu...

Страница 4: ...Default OFF OFF OFF OFF OFF OFF 04 24 Hour Protection Zones Zone 1 Zone 2 Zone 3 Zone 4 Zone 5 Zone 6 Default OFF OFF OFF OFF OFF OFF 05 40 ms Loop Response Zones Zone 1 Zone 2 Zone 3 Zone 4 Zone 5 Zo...

Страница 5: ...able Output PGM Features 1 Zn 1 LED ON Audio Verification Zn 2 LED ON Access Output Zn 3 LED ON Follow Keypad Sounder Zn 4 LED ON Keyfob Keyswitch Chirp See Note 2 Default OFF OFF OFF OFF 24 Programma...

Страница 6: ...OFF OFF 39 Opening Closing Report Telco 1 Zn 1 LED ON User 1 Reporting Zn 2 LED ON User 2 Reporting Zn 3 LED ON User 3 Reporting Zn 4 LED ON User 4 Reporting Zn 5 LED ON User 5 Reporting Zn 6 LED ON U...

Страница 7: ...gle Digit Zn 4 LED ON No Handshake Default ON OFF ON OFF 45 Communicator Features 1 Zn 1 LED ON Communicator Enabled Zn 2 LED ON DTMF w Rotary Back up Zn 3 LED ON DTMF only Zn 4 LED ON Backup to Telco...

Страница 8: ...Zone 4 Zone 5 Zone 6 Default OFF OFF OFF OFF OFF OFF 55 Zone Restore Report Telco 3 Zone 1 Zone 2 Zone 3 Zone 4 Zone 5 Zone 6 Default OFF OFF OFF ON 56 System Reporting Telco 3 Zn 1 LED ON KP Fire Zn...

Страница 9: ...F 63 System Report Codes Keypad Fire 1 1 Keypad AUX 2 3 Keypad Panic 2 1 Test Timer F F AC Fail F 9 Low Battery F 8 Trouble F 1 Fire 1 1 64 System Restore Code E 65 Opening and Closing Code C Closing...

Страница 10: ...eyfob 3 84 Keyfob 4 AUX 1 2 Programming 1 Panic 2 AUX 3 Bell ON 4 PGM 5 Instant 6 Access on PGM 7 Full Set System 8 Interior 6PRNH HWHFWRUV RF ID Hexadecimal Data Entry To Enter a hexadecimal digit en...

Страница 11: ...ne override Zn 3 LED ON Command 6 Download Zn 4 LED ON Signal Strength Test Mode Default ON OFF OFF OFF 96 Dealer Options 1 Zn 1 LED ON Dealer Code Lockout Zn 2 LED ON User 1 Code Lockout Zn 3 LED ON...

Страница 12: ...K EOLR SUPERVISED E COLD WATER GROUND CONNECTION USE ONLY COLD WATER PIPE OR BURIED GROUND ROD USE AT LEAST 16 AWG WIRE TELCO RED GRN GRAY BRN FIRE PWR 2 A P 0 REMOTE BUS ZONE 3 E E ZONE 6 ZONE 5 Z ZO...

Отзывы: