NAPCO EXPRESS XP-600 Скачать руководство пользователя страница 2

2

7\SHV RI 3URJUDPPLQJ %ORFNV

LED Programming Block

                                          
Enable features by pressing the key that corresponds to the associated feature; the LED will turn ON.  To disable a feature press the key
again;  the LED will turn OFF.  To disable all features within a LED Type Programming Block press the 

 key; all LEDs will turn OFF.

LED Programming Block Example
Program zones 2 and 3  as 

Follower Zones.

1.  Enter Programming Block 02, by pressing

 (Beep), then 

 (Beep).

2. Press the 

 key to select zone 2.

3. Press the 

 key to select zone 3.

Zone 2 and Zone 3
LEDs are ON indi-
cating that zones 2
and 3 have been
programmed as fol-
lower zones.

1

LED Type
Programming
Block

Direct Entry Programming Example 2 
(Hexadecimal data entry)
Program 

Telephone Prefix Number  with a 9E.

1.  Press 

 (Beep) 

  (Beep).

2.  Press 

3.  Press 

4.  Press 

2

Direct Entry Programming Block

                                                       
Enter data directly.  For hexadecimal entries of A-F,  use the 

 key + 

 

  through 

  

keys, respectively.  Use the

key to blank out digits in Direct Entry type programming blocks.  Default values are shown in parentheses.

Direct Entry Programming Example 1 
Program the panel for a 60 second Exit Delay.

1.  Press 

  (Beep) 

 

  (Beep)

2.  Press 

.

1

0

6

0

Exit Delay, seconds

(0) (4) (5) Maximum Entry 255

10

Exit Delay

9

E

44

Dialing Prefix

Direct Entry
Type
Programming
Blocks

02

Exit/Entry Follower

Zone 1
Zone 2
Zone 3
Zone 4
Zone 5
Zone 6

Default

OFF

OFF

OFF

OFF

OFF

OFF

²

²

=21( 

=21( 
=21( 
=21( 

=21(

 

=21( 

READY

ARMED

OFF

FLASHING

FLASHING

SYSTEM

9

Indicates the panel is in
Dealer Program Mode and
the next digit entered will be
interpreted as a Hexadeci-
mal digit.  Valid entries are
1-6 (A-F).

Wi847c 
page 2

Tuesday, September 16, 1997 08:35 

Содержание EXPRESS XP-600

Страница 1: ...all original wiring for ter minal 15 PGM and terminal 3 Note Any programming in Dealer Options 1 96 and Dealer Options 2 97 will not be de faulted If Dealer Code Lockout has been programmed the panel...

Страница 2: ...adecimal data entry Program Telephone Prefix Number with a 9E 1 Press Beep Beep 2 Press 3 Press 4 Press 2 Direct Entry Programming Block Enter data directly For hexadecimal entries of A F use the key...

Страница 3: ...rs Phone Numbers Pager Leading and Trailing digits and Report Codes NOTE Example Viewing the Dialing Prefix A Dialing Prefix of 9E has been programmed at Programming Block Num ber 44 outside access nu...

Страница 4: ...Default OFF OFF OFF OFF OFF OFF 04 24 Hour Protection Zones Zone 1 Zone 2 Zone 3 Zone 4 Zone 5 Zone 6 Default OFF OFF OFF OFF OFF OFF 05 40 ms Loop Response Zones Zone 1 Zone 2 Zone 3 Zone 4 Zone 5 Zo...

Страница 5: ...able Output PGM Features 1 Zn 1 LED ON Audio Verification Zn 2 LED ON Access Output Zn 3 LED ON Follow Keypad Sounder Zn 4 LED ON Keyfob Keyswitch Chirp See Note 2 Default OFF OFF OFF OFF 24 Programma...

Страница 6: ...OFF OFF 39 Opening Closing Report Telco 1 Zn 1 LED ON User 1 Reporting Zn 2 LED ON User 2 Reporting Zn 3 LED ON User 3 Reporting Zn 4 LED ON User 4 Reporting Zn 5 LED ON User 5 Reporting Zn 6 LED ON U...

Страница 7: ...gle Digit Zn 4 LED ON No Handshake Default ON OFF ON OFF 45 Communicator Features 1 Zn 1 LED ON Communicator Enabled Zn 2 LED ON DTMF w Rotary Back up Zn 3 LED ON DTMF only Zn 4 LED ON Backup to Telco...

Страница 8: ...Zone 4 Zone 5 Zone 6 Default OFF OFF OFF OFF OFF OFF 55 Zone Restore Report Telco 3 Zone 1 Zone 2 Zone 3 Zone 4 Zone 5 Zone 6 Default OFF OFF OFF ON 56 System Reporting Telco 3 Zn 1 LED ON KP Fire Zn...

Страница 9: ...F 63 System Report Codes Keypad Fire 1 1 Keypad AUX 2 3 Keypad Panic 2 1 Test Timer F F AC Fail F 9 Low Battery F 8 Trouble F 1 Fire 1 1 64 System Restore Code E 65 Opening and Closing Code C Closing...

Страница 10: ...eyfob 3 84 Keyfob 4 AUX 1 2 Programming 1 Panic 2 AUX 3 Bell ON 4 PGM 5 Instant 6 Access on PGM 7 Full Set System 8 Interior 6PRNH HWHFWRUV RF ID Hexadecimal Data Entry To Enter a hexadecimal digit en...

Страница 11: ...ne override Zn 3 LED ON Command 6 Download Zn 4 LED ON Signal Strength Test Mode Default ON OFF OFF OFF 96 Dealer Options 1 Zn 1 LED ON Dealer Code Lockout Zn 2 LED ON User 1 Code Lockout Zn 3 LED ON...

Страница 12: ...K EOLR SUPERVISED E COLD WATER GROUND CONNECTION USE ONLY COLD WATER PIPE OR BURIED GROUND ROD USE AT LEAST 16 AWG WIRE TELCO RED GRN GRAY BRN FIRE PWR 2 A P 0 REMOTE BUS ZONE 3 E E ZONE 6 ZONE 5 Z ZO...

Отзывы: