9
3. INItIAL USE
Warning:
Ensure that all packaging material and foils have been
removed before switching on the burner or the element for
the first time.
2.3. Connecting Mains (EC.U.1.E.)
- Before connecting the device electrically, refer first to the specifications on the type
plate on the device, the technical specifications on page 2.
- All electrical supplies to the device must be grounded.
- If the available electrical supplies are not suitable, contact an accredited installer
and/or your electricity supply company.
- The device must be connected by permanent, direct connection.
- Have connections and modifications only done by qualified professionals.
Model EC.U.1.G.
- 1 power cable (with plug) for the motor
Model EC.U.1.E.
- 1 socket (page 4, 17) to connect the motor
- 2 power cables (with plug) ,1 for the motor, 1 for the electrical element
2.4. Connecting Motor
Motor specifications
Mains
: 230 V – 50 Hz
Power consumption
: 4 W
Revolutions
: 1 Revolution per minute